BRADFORD WHITE CEHD120 24 to 36 kW Commercial Electric Water Heater (119 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: CEHD120 (24-36 kW)
450 L119 US gal of storage
24–36 kWof power, your choice
64.69 intall
Talk to an expert · 514 316-2973
1 1/2 in NPT connections
01 · Why this model

What sets the Bradford White CEHD120 24 to 36 kW apart

149 GPH

Recovery at 36 kW

Bradford White sheet C1401 lists 149 US gallons per hour at a 100 °F rise at 36 kW.

6 elements

Power range

The 6-element version can be set anywhere in the 24 to 36 kW range only, on the same tank.

430 lb

Shipping weight

The standard model ships at about 430 lb (485 lb with ASME construction).

3 in

Foam insulation

3 in (76 mm) of non-CFC foam covers the tank sides and top, and the tank has two anode rods.

02 · How it works

Cold water at the bottom, hot water on top

Cold watergoes down the dip tubeHot waterdrawn from the topUpper elementand its thermostatLower elementand its thermostatCold waterarrives at the bottom
  1. Cold water arrives at the bottom of the tank. Hot water, being lighter, stays on top, where it is drawn.
  2. The elements, each controlled by its thermostat, bring the water back to the set temperature.
  3. Foam insulation limits the heat lost while the water waits.
03 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 64.69 in tall (1643 mm), 30.25 in across (768 mm), about 430 lb shipping weight. The clearances the manufacturer requires are checked on site.

04 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

05 · Installation

What the spot needs, and who does what

Electrical circuit24 to 36 kW depending on the configuration ordered, three-phase.
1 1/2 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up.

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

06 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
07 · Spec sheet

Every figure, with its source

Capacity and performance
Model
CEHD120 (24-36 kW)
Capacity
119 US gal · 450 L
Recovery
149 US gal/h · 564 L/h
Electrical
Power
24 to 36 kW
Element type
Screw-in low watt density Incoloy
Dimensions and connections
Height
64.69 in · 1,643 mm
Diameter
30.25 in · 768 mm
Shipping weight (approx.)
430 lb · 195 kg
Water connections
1 1/2 in NPT
Build and warranty
Inner lining
Vitraglas with Microban
Drain valve
Brass

Manufacturer data. Detailed sources at the bottom of the page.

08 · Same family

The size below and above

80 US gal61.25 in tallSee the smaller one
119 US gal64.69 in tallYou are here
09 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Who does the installation?

AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).

10 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White Canada ElectriFLEX HD spec sheet C1401-H-0823 CANADA · cdn.shopify.com
  2. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  3. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  4. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  5. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A large reserve and solid recovery so your guests never take a lukewarm shower

In a hotel, an inn or a student residence, hot water is part of the experience. A guest who gets a lukewarm shower remembers it, and talks about it. The Bradford White CEHD120 commercial electric water heater, in its six-element version offered from 24 to 36 kW, is designed for that level of expectation. It combines a 119 US gallon tank (100 imperial gallons, 450 L) with enough power to rebuild the reserve quickly, even when every room is full. AirGreen installs it in lodging establishments and large buildings in Montreal, Laval, Longueuil, the South Shore and the North Shore.

It is for owners of boutique hotels, motels and B&Bs, managers of student residences and owners of good-sized apartment buildings who want a reliable central supply that is easy to maintain.

Lodging, a demand that is hard to predict

Unlike an office or a school, a lodging establishment does not follow a fixed schedule. Some guests shower early to catch a flight, others late after a show, and the housekeeping team runs the washers between check-outs and check-ins. The water heater must therefore keep a large reserve for busy mornings and recover quickly the rest of the day.

With 119 US gallons and six elements, the CEHD120 meets both needs. The reserve absorbs the wave of showers before check-out time, and the installed power gets the water ready for the laundry and for afternoon arrivals.

Manufacturer data for the six-element CEHD120

  • Capacity: 119 US gallons (100 imperial gallons, 450 L).
  • Elements: six standard screw-in elements, Incoloy-sheathed, low watt density.
  • Power ratings offered: 24, 27, 30, 36 kW.
  • Water connections: 1 1/2 in. (38 mm) NPT, factory-installed true dielectric fittings.
  • Tank: Vitraglas lining with Microban.
  • Drain valve: brass, low restriction, vandal-resistant design.
  • Height: 64 11/16 in. (1,643 mm). Diameter: 30 1/4 in. (768 mm).
  • Weight: 430 lb (195 kg), standard model.

Six elements, from 24 to 36 kW

Bradford White specifies that six-element models "can be converted from 24 kW to 36 kW ONLY". For an establishment, that rule has a practical benefit: if you add rooms or a fitness room, the unit’s power can be increased within that range without replacing it. Conversely, conversion cannot go below 24 kW or above 36 kW.

The starting power is chosen according to the number of rooms or units, the presence of a laundry or a kitchen, and the available electrical capacity. We set it with you, then write it into the quote.

The electrical supply

The CEHD120 is ordered at 208 V, 240 V, 277 V, 380 V, 415 V, 480 V or 600 V; voltage and phase must be specified when ordering. All units are shipped from the factory as standard three-phase models, and on 600 V models, only conversion of the kW rating is permitted. Before recommending a configuration, we check the main panel nameplate, the remaining capacity and the wiring route to the mechanical room.

One tank or two in parallel

In an establishment where a hot water outage would be unacceptable, it can be wise to split production between two tanks rather than relying on a single unit. If one is being serviced, the other keeps supplying the rooms. That decision depends on the size of the establishment, the space available and the electrical capacity. We present both options when the situation warrants it, with their advantages and constraints.

Installing a 430 lb tank

The CEHD120 measures 30 1/4 in. in diameter and 64 11/16 in. in height, and weighs 430 lb empty. In a hotel set in an older building, access to the mechanical room may go through a freight elevator, a service staircase or a narrow door. We measure every passage and plan the handling equipment before delivery. Once filled, the tank requires a floor able to carry a significant load, a floor drain for the relief valve and flushing, and clearance in front of the elements.

Protection and durability

The inside of the tank is lined with Vitraglas with Microban, an antimicrobial technology. The factory-installed true dielectric fittings limit corrosion at the joint with the piping, and the vandal-resistant brass drain valve stands up to handling in a utility room used by staff. The six Incoloy-sheathed elements are screw-in and are replaced individually.

Maintenance that does not disturb guests

We recommend a maintenance visit once a year, scheduled during a quieter period: flushing through the low-restriction valve, checking the elements and their connections, and testing the relief valve. When the installation includes two tanks, maintenance is done one after the other, without cutting hot water to the rooms.

Standards and items confirmed at ordering

According to Bradford White’s documentation, the CEHD design is UL certified for field conversion, ASME construction is available and NSF kits are offered, which is useful if the establishment runs a kitchen. The full model number, which specifies the power, voltage, phase and ASME option, is set with you and confirmed at ordering. The manufacturer’s warranty terms that apply to the selected unit are stated in the written quote.

Installation of the Bradford White CEHD120 (24 to 36 kW) by AirGreen

AirGreen is a family business established in Montreal, active for more than fifteen years in heating, ventilation and air conditioning and holder of RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). In a lodging establishment, we organize the work to keep the impact on your guests to a minimum. Our work includes:

  • a free on-site assessment of demand, the mechanical room, access routes and the electrical service;
  • a recommendation on power, electrical configuration and, where needed, a two-tank installation, confirmed in a written quote;
  • draining and removing the old tank, then disposing of it;
  • connecting the cold and hot water in 1 1/2 in., the relief valve and its discharge;
  • the electrical connections, made under our RBQ licence;
  • commissioning, temperature setting and a check of each element;
  • a maintenance schedule suited to your busy periods.

Service area

We work in Montreal, from Old Montreal to Plateau-Mont-Royal, in Laval, Longueuil, Brossard, Boucherville, Saint-Sauveur and throughout the South Shore and the North Shore.

Request your free on-site estimate for the Bradford White CEHD120, 24 to 36 kW. You will receive a detailed written quote, and financing options are available for your establishment.