BRADFORD WHITE CEHD80 45 to 54 kW Commercial Electric Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: CEHD80 (45-54 kW)
303 L80 US gal of storage
45–54 kWof power, your choice
61.25 intall
Talk to an expert · 514 316-2973
1 1/2 in NPT connections
01 · Why this model

What sets the Bradford White CEHD80 45 to 54 kW apart

223 GPH

Recovery at 54 kW

Bradford White sheet C1401 lists 223 US gallons per hour at a 100 °F rise at 54 kW.

9 elements

Power range

The 9-element version can be set anywhere in the 45 to 54 kW range only, on the same tank.

335 lb

Shipping weight

The standard model ships at about 335 lb (378 lb with ASME construction).

3 in

Foam insulation

3 in (76 mm) of non-CFC foam covers the tank sides and top, and the tank has two anode rods.

02 · How it works

Cold water at the bottom, hot water on top

Cold watergoes down the dip tubeHot waterdrawn from the topUpper elementand its thermostatLower elementand its thermostatCold waterarrives at the bottom
  1. Cold water arrives at the bottom of the tank. Hot water, being lighter, stays on top, where it is drawn.
  2. The elements, each controlled by its thermostat, bring the water back to the set temperature.
  3. Foam insulation limits the heat lost while the water waits.
03 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 61.25 in tall (1556 mm), 26 in across (660 mm), about 335 lb shipping weight. The clearances the manufacturer requires are checked on site.

04 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

05 · Installation

What the spot needs, and who does what

Electrical circuit45 to 54 kW depending on the configuration ordered, three-phase.
1 1/2 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up.

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

06 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
07 · Spec sheet

Every figure, with its source

Capacity and performance
Model
CEHD80 (45-54 kW)
Capacity
80 US gal · 303 L
Recovery
223 US gal/h · 844 L/h
Electrical
Power
45 to 54 kW
Element type
Screw-in low watt density Incoloy
Dimensions and connections
Height
61.25 in · 1,556 mm
Diameter
26 in · 660 mm
Shipping weight (approx.)
335 lb · 152 kg
Water connections
1 1/2 in NPT
Build and warranty
Inner lining
Vitraglas with Microban
Drain valve
Brass

Manufacturer data. Detailed sources at the bottom of the page.

08 · Same family

The size below and above

09 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Who does the installation?

AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).

10 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White Canada ElectriFLEX HD spec sheet C1401-H-0823 CANADA · cdn.shopify.com
  2. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  3. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  4. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  5. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

Hot showers for one team, then the next: 80 US gallons and nine elements for locker rooms

In an arena, a sports centre or a swim club, hot water demand arrives all at once. A game ends, twenty players hit the showers at the same time, and the next team is already waiting its turn. The Bradford White CEHD80 commercial electric water heater, in its nine-element version offered at 45 kW or 54 kW, is built for these successive waves. Its 80 US gallon tank (67 imperial gallons, 303 L) absorbs the first rush, and its installed power brings it back to temperature before the next. AirGreen installs it in sports facilities and institutional buildings in Montreal, Laval, Longueuil, the South Shore and the North Shore.

This model is of interest to managers of municipal or private sports centres, schools with locker rooms, high-traffic gyms and training studios, as well as camps and outdoor centres that host groups.

The locker-room peak, a particular challenge

Most buildings use their hot water in a spread-out way. A locker room uses it in very short, very intense blocks. During those few minutes, the reserve drops quickly; between two blocks, the unit has only a short interval to recover. That interval decides whether the second team gets hot water or lukewarm water.

A large tank with little power often fails that test: it handles the first group well, then runs out of breath. The nine-element CEHD80 answers this scenario by combining a comfortable reserve with high installed power. We always validate that choice against your real schedule: number of locker rooms, frequency of games and classes, shower head flow.

Manufacturer data for the nine-element CEHD80

  • Capacity: 80 US gallons (67 imperial gallons, 303 L).
  • Elements: nine standard screw-in elements, Incoloy-sheathed, low watt density.
  • Power ratings offered: 45 kW or 54 kW; nine-element models "can be converted from 45 kW to 54 kW ONLY".
  • Available voltages: 208 V, 240 V, 277 V, 380 V, 415 V, 480 V and 600 V, units shipped as standard three-phase.
  • Water connections: 1 1/2 in. (38 mm) NPT, factory-installed true dielectric fittings.
  • Tank: Vitraglas lining with Microban.
  • Drain valve: brass, low restriction, vandal-resistant design.
  • Dimensions: 61 1/4 in. (1,556 mm) high, 26 in. (660 mm) in diameter.
  • Weight: 335 lb (152 kg), standard model.

Nine elements: 45 kW or 54 kW

The nine-element version comes in only two power ratings, and the manufacturer allows the unit to be converted from one to the other. That flexibility is useful in a sports centre whose traffic changes: a unit installed at 45 kW can move to 54 kW if a new league or a new schedule raises demand, provided the electrical service allows it.

The initial choice rests on peak demand and the building’s capacity. We calculate the need from your schedule, then check what the panel can accept. The selected power is written into the quote and confirmed at ordering, along with the voltage and phase.

What this power means for the building

A 45 kW or 54 kW water heater is a significant load, comparable to several large appliances combined. It requires an electrical service able to supply it, a breaker and conductors of the right size, and a wiring route to the mechanical room. The manufacturer ships every unit in the standard three-phase configuration, and the voltage, chosen among the values offered from 208 V to 600 V, must be specified when ordering. On 600 V models, only conversion of the kW rating is permitted.

Depending on the building’s electricity rate, power demand can also affect the bill. That is one more reason to size the unit precisely rather than reaching for the maximum by reflex.

Where to install it in a sports complex

The ideal spot is a mechanical room close to the locker rooms, to limit piping length and the wait for hot water at the showers. The CEHD80 measures 26 in. in diameter and 61 1/4 in. in height and weighs 335 lb empty: it needs a solid floor, access through a wide enough door and a floor drain for the relief valve and flushing. Nine elements also call for enough clearance in front of the access panels, which we reserve from the planning stage.

Sturdy enough for a public building

In a building open to the public, equipment has to stand up to handling. The low-restriction brass drain valve has a vandal-resistant design, and the factory-installed true dielectric fittings protect the joint between the tank and the piping. The inside of the tank is lined with Vitraglas with Microban, an antimicrobial technology. According to Bradford White’s documentation, the design is UL certified for field conversion, ASME construction is available and NSF kits are offered.

Maintenance in season and off season

Many sports facilities live by the seasons. We recommend using a quiet period for the annual maintenance: flushing through the brass valve, which clears sediment well, checking the nine elements and their connections, and testing the relief valve. The screw-in elements are replaced one at a time, which avoids shutting the locker rooms during the season.

Model number and warranty

The full model number of a CEHD specifies the power, voltage, phase and ASME option; it is therefore set with you and confirmed at ordering. The manufacturer’s warranty terms that apply to the selected unit are stated in the written quote, along with the documentation to hand to the building manager.

Installation of the Bradford White CEHD80 (45 to 54 kW) by AirGreen

AirGreen is a family business established in Montreal, active for more than fifteen years in heating, ventilation and air conditioning and holder of RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). In a sports centre, we schedule the replacement around the activity calendar to avoid closing the locker rooms mid-season. Our work includes:

  • a free on-site assessment of peak demand, the mechanical room and the electrical service;
  • a recommendation on power, voltage and phase, confirmed in a written quote;
  • draining and removing the old unit, then disposing of it;
  • connecting the cold and hot water in 1 1/2 in., the relief valve and its discharge;
  • the electrical connections, made under our RBQ licence;
  • commissioning, temperature setting and a check of all nine elements;
  • a maintenance plan aligned with your calendar.

Service area

We work in Montreal, Laval, Longueuil, Brossard, Terrebonne, Repentigny, Vaudreuil-Dorion and throughout the South Shore and the North Shore.

Request your free on-site estimate for the Bradford White CEHD80, 45 to 54 kW. You will receive a detailed written quote, and financing options are available for your project.