BRADFORD WHITE SS-120-L Indirect Water Heater (111 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: SS-120-L
420 L111 US gal of storage
1,548 Lof hot water in the first hour
Lifetimetank warranty
Talk to an expert · 514 316-2973
Lifetime tank warranty, 6-year parts1 in NPT connections
01 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 1,548 L

An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

02 · Why this model

What sets the Bradford White SS-120-L apart

444

Stainless steel

Tank and coil are 444 ferritic stainless steel (chromium-molybdenum-titanium), with no glass lining to protect.

1 in

Larger connections

The only model in the series with 1 in NPT potable connections and a 30-1/4 in diameter; minimum boiler flow is only 9 gpm.

409 gal

AHRI first hour

Certified 409 gal first-hour and 319 gal/h continuous at 135 °F, with a boiler of at least 199,000 BTU/h at 180 °F.

Lifetime

Residential warranty

Bradford White gives a limited lifetime warranty on the tank and heat exchanger in residential use, and 6 years on parts (5 yrs / 1 yr commercial).

03 · How it works

The boiler heats the water without ever touching it

Boilerheat sourceboiler waterHeat exchangertwo separate circuitsHot waterto the houseCold waterfrom the mains
  1. When the tank calls for heat, its control starts the boiler loop.
  2. Boiler water and drinking water flow in two separate circuits: heat passes through the exchanger wall.
  3. No electric element: all the heat comes from the boiler that already heats the house.
04 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 63.38 in tall (1610 mm), 30.25 in across (768 mm), about 217 lb shipping weight. The clearances the manufacturer requires are checked on site.

05 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

06 · Installation

What the spot needs, and who does what

A boilerIts ratings are published with a 199,000 BTU/h boiler. The heating contractor checks yours.
Boiler loopCirculator or zone valve, with the tank control wired to the boiler.
1 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

07 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. With the boilerThe heating contractor checks the loop, circulator and tank control during the boiler service.
08 · Spec sheet

Every figure, with its source

Capacity and performance
Model
SS-120-L
Capacity
111 US gal · 420 L
First-hour rating
409 US gal · 1,548 L
Continuous draw
319 US gal/h · 1,207 L/h
Reference boiler
199,000 BTU/h
Recovery
319 US gal/h · 1207 L/h
Dimensions and connections
Height
63.38 in · 1,610 mm
Diameter
30.25 in · 768 mm
Shipping weight (approx.)
217 lb · 98 kg
Water connections
1 in NPT (potable water) ; 1 in NPT female (coil, supply and return)
Heat exchanger
Single-wall stainless steel coil heat exchanger
Build and warranty
Inner lining
Stainless steel 444
Limited warranty, tank
Lifetime
Limited warranty, parts
6 years

Manufacturer data. Detailed sources at the bottom of the page.

09 · Same family

The size below and above

73 US gal65.63 in tallSee the smaller one
111 US gal63.38 in tallYou are here
10 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Do I need a boiler?

Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 111 gallons enough for?

It delivers 1,548 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).

11 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White PowerStor Series SS spec sheet C556 CANADA · docs.bradfordwhite.com
  2. Bradford White For The Pro - PowerStor SS Indirect product page · forthepro.bradfordwhite.com
  3. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  4. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  5. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  6. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  7. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A large stainless steel indirect reserve for electrically heated buildings and businesses

When several apartments, a daycare, a hair salon or a locker room with showers depend on the same hot water source, a residential tank is no longer enough. The Bradford White SS-120-L indirect water heater stores 111 US gallons (92 imperial gallons, 420 L) of potable water, heated by a stainless steel coil connected to an electric boiler. It is the largest tank in the SS series that we offer, and the only one in the series with 1 in. potable water connections. AirGreen installs it in buildings in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

Which buildings this tank is designed for

The SS-120-L is aimed first at small multi-unit buildings whose central heating runs on an electric boiler, at businesses that use a lot of hot water in a short time, and at very large homes. In a converted plex where each apartment had its own tank, a central indirect tank can also simplify maintenance, provided the boiler and the distribution allow it. Every case calls for an analysis: number of plumbing fixtures, simultaneous use, peak hours and boiler capacity. We do this calculation before proposing the model.

Manufacturer specifications

  • Capacity: 111 US gallons, 92 imperial gallons, 420 L.
  • First-hour rating (AHRI): 409 gal/h (1,548 L/h), with boiler water at 180 °F (82 °C).
  • Continuous draw: 319 gal/h at 135 °F (1,208 L/h at 57 °C).
  • Standby heat loss: 0.3 °F/h (0.16 °C/h).
  • Minimum heat source input: 199,000 BTU/h.
  • Minimum heat source flow: 9.0 gal/min (34.0 L/min).
  • Maximum boiler supply temperature: 240 °F (116 °C).
  • Heat exchanger: single-wall stainless steel coil, 1 in. (25 mm) outside diameter.
  • Connections: potable water in 1 in. NPT; boiler in 1 in. (25 mm) female NPT at the front, supply and return.
  • Dimensions: height of 63 3/8 in. (1,610 mm), diameter of 30 1/4 in. (768 mm).
  • Weight: 217 lb (98 kg) empty.

The indirect principle applied to a large volume

The tank has no heating element. Boiler water flows through the coil, gives up its heat to the potable water and returns to the boiler, without ever coming into contact with the domestic water. On a 420 L volume, this heating method has a clear advantage: the boiler recharges the reserve while the water is being used, which gives a first-hour rating of 409 gal/h and a continuous draw of 319 gal/h at 135 °F. For a building where morning showers are concentrated in a short period, this recharging capacity matters as much as the stored volume.

Pairing the SS-120-L with a high-output electric boiler

Bradford White states that these ratings are obtained with a heat source of at least 199,000 BTU/h, a flow of at least 9.0 gal/min and boiler water at 180 °F (82 °C). The manufacturer also specifies that different conditions give different results. A smaller electric boiler will heat the reserve properly, but more slowly; in a building, this can mean less hot water at the end of the peak. We therefore size the whole system: boiler output, the share reserved for heating in extreme cold, circulator flow and priority control. If the existing boiler cannot keep up, we present the options before starting the work.

1 in. potable water connections

Unlike the smaller models in the series, which use 3/4 in. connections, the SS-120-L takes in cold water and delivers hot water through 1 in. NPT fittings. This larger diameter limits pressure loss when several apartments or several fixtures draw at the same time. The boiler connections, also 1 in. NPT, are at the front of the tank to make piping easier in a mechanical room.

444 stainless steel and low standby loss

The tank and heat exchanger are made of 444 ferritic stainless steel, a chromium, molybdenum and titanium alloy. There is no internal lining to monitor. With a standby loss of 0.3 °F/h, the lowest of the SS tanks we offer, the large reserve holds its temperature well overnight and during quiet hours. The model's ratings are AHRI certified.

Handling and location

With a diameter of 30 1/4 in. and an empty weight of 217 lb, the SS-120-L requires preparation. We measure the doors, hallways and stairs leading to the mechanical room, and we check that the slab or floor can support the tank once filled with 420 L of water. Service space around the front connections and the relief valve is planned from the first visit.

Residential or commercial warranty

Bradford White applies different warranty terms depending on the use, residential or commercial. For a tank of this size, the category depends on your building: we state it clearly in the written quote.

Installation of the SS-120-L by AirGreen in Greater Montreal buildings

AirGreen is a family-owned heating and cooling company established in Montreal and active for more than fifteen years. We hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Every project starts with a free on-site estimate and continues with a written quote. Installation includes:

  • analysing the building's hot water demand and the output of the electric boiler;
  • assessing the location, access and floor capacity;
  • draining and removing the old tanks, where applicable;
  • connecting the coil to the boiler in 1 in. NPT, with a circulator and priority control;
  • connecting the cold and hot water in 1 in. NPT, with a thermostatic mixing valve if the use calls for it;
  • installing the relief valve and its discharge line;
  • commissioning, purging air from the loop and setting the temperatures;
  • a maintenance plan suited to heavy use.

Maintaining a heavily used tank

In a building or a business, the tank works harder than in a house. We recommend at least one visit per year: a partial flush to remove sediment, a test of the relief valve, and a check of the fittings, the circulator and the boiler control. For building owners, this regular follow-up avoids learning about a breakdown from a tenant's call.

Service area

We work in Montreal, Laval, Longueuil, Brossard, Saint-Laurent, Anjou, LaSalle, Terrebonne and everywhere on the South Shore and the North Shore. Owners can spread out the investment through our financing.

Request your free estimate for the Bradford White SS-120-L. Send us the number of apartments or fixtures, and a photo of the boiler and its nameplate: we will prepare a visit and a written quote.