No stored potable water
Potable water runs through copper coils and is heated on demand: the 120 gal tank holds boiler water, not the water you drink.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Potable water runs through copper coils and is heated on demand: the 120 gal tank holds boiler water, not the water you drink.
The copper coils provide 58.9 sq ft of exchange surface for a maximum domestic hot water flow of 27 gpm, per Thermo 2000.
This 120-9A is built to ASME Section VIII Div. 1, rated 200 psi maximum (tank and exchanger), weighing 540 lb.
Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.
It travels upright. Measure the ceiling at the spot and the narrowest door on the way.
Unit: 77.44 in tall (1967 mm), 28 in across (711 mm), about 540 lb shipping weight. The clearances the manufacturer requires are checked on site.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, coordination of the work.
HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 3,929 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
In a residential tower, an institutional building or an industrial site, water often circulates at a higher pressure than in a house, pushed by a booster pump to reach the upper floors or supply demanding equipment. The Thermo 2000 TurboMax 120-9A 200 indirect water heater is made for these networks: its maximum pressure reaches 200 psi. It combines a 120 US gallon tank, a 58.9 sq. ft. copper coil system and 2 1/2 in potable water connections, with an electric boiler as the heat source. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
Every unit connected to a building’s water network must withstand the pressure in it, including during peaks and water hammer. In a tall building, pressure is higher on the lower floors, where the mechanical room is usually located. A tank with a 200 psi maximum pressure offers a comfortable margin under these conditions. It also allows hot water production to be installed on the high-pressure side of the network when the design requires it, rather than multiplying pressure-reducing valves.
This model is aimed at buildings where both pressure and demand are high. A residential tower whose mechanical room is in the basement, a healthcare or education facility whose network is kept under pressure by a booster pump, an industrial building where hot water supplies washing stations. In each of these cases, the 120 US gallon reserve absorbs the peaks and the exchanger keeps production going as long as the electric boiler supplies the necessary heat. The 27 gpm maximum flow and the 2 1/2 in connections suit large-diameter distribution.
A high maximum pressure does not remove the need for safety devices. The relief valve is chosen according to the tank’s maximum pressure and capacity, an expansion tank absorbs the expansion of the heated water, and a pressure-reducing valve remains useful when supply pressure exceeds what the other components of the installation accept. We measure the real pressure, including while the booster pump is running, before finalizing the design.
According to Thermo 2000, the high-exchange-capacity copper coil system heats water instantly. Its exchanger can transfer up to 1,165,000 BTU/h (341 kW) for water at 110 °F, which gives 2,122 US GPH in the first hour and 2,002 US GPH continuous at full capacity. These values assume the boiler supplies that output, which is not the case for every electric boiler; the real continuous output follows the boiler’s capacity and therefore the building’s electrical service. The manufacturer adds that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the expected output with your boiler.
The TurboMax 120-9A 200 weighs 540 lb empty and is 76 3/4 in high and 28 in in diameter. In a tower, delivery sometimes goes through a freight elevator or a service entrance; in an industrial building, through a garage door. We plan the route, the handling equipment, the floor capacity once the tank is filled, access to a drain and the service space around the fittings and drain valve.
Thermo 2000 offers a 10-year commercial warranty, a 15-year residential warranty and a 2-year warranty on mechanical components. The category applicable to your building is confirmed in writing with the quote.
AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For this high-pressure indirect water heater, our work includes:
We work with property managers, institutions and companies in Montreal, Laval, Longueuil, downtown, Nuns’ Island, Saint-Laurent, Boucherville, Terrebonne and across the South Shore and the North Shore. The on-site estimate is free, the quote is written and financing is available.
Request your free quote for the Thermo 2000 TurboMax 120-9A 200. Send us your network pressure and your boiler’s specifications: we will propose a safe, complete configuration.