THERMO 2000 TURBOMAX120-9A 125 Indirect Water Heater (120 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TURBOMAX120-9A 125
454 L120 US gal of storage
3,929 Lof hot water in the first hour
15 yrstank warranty
Talk to an expert · 514 316-2973
15-year tank warranty, 2-year parts2 in male copper sweat connections
01 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 3,929 L

An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

02 · Why this model

What sets the Thermo 2000 TurboMax 120-9A-125 apart

Instant

No stored potable water

Potable water runs through copper coils and is heated on demand: the 120 gal tank holds boiler water, not the water you drink.

58.9 sq ft

Heat-transfer area

The copper coils provide 58.9 sq ft of exchange surface for a maximum domestic hot water flow of 27 gpm, per Thermo 2000.

125 psi

ASME version

This 120-9A is built to ASME Section VIII Div. 1, rated 125 psi maximum (tank and exchanger), weighing 450 lb.

15 yrs

Residential warranty

Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.

03 · How it works

The boiler heats the water without ever touching it

Boilerheat sourceboiler waterHeat exchangertwo separate circuitsHot waterto the houseCold waterfrom the mains
  1. When the tank calls for heat, its control starts the boiler loop.
  2. Boiler water and drinking water flow in two separate circuits: heat passes through the exchanger wall.
  3. No electric element: all the heat comes from the boiler that already heats the house.
04 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 77.44 in tall (1967 mm), 28 in across (711 mm), about 450 lb shipping weight. The clearances the manufacturer requires are checked on site.

05 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

06 · Installation

What the spot needs, and who does what

A boilerIts ratings are published with a 820,000 BTU/h boiler. The heating contractor checks yours.
Boiler loopCirculator or zone valve, with the tank control wired to the boiler.
2 in male copper sweat waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

07 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. With the boilerThe heating contractor checks the loop, circulator and tank control during the boiler service.
08 · Spec sheet

Every figure, with its source

Capacity and performance
Model
TURBOMAX120-9A 125
Capacity
120 US gal · 454 L
First-hour rating
1038 US gal · 3,929 L
Continuous draw
990 US gal/h · 3,747 L/h
Reference boiler
820,000 BTU/h
Recovery
990 US gal/h · 3747 L/h
Dimensions and connections
Height
77.44 in · 1,967 mm
Diameter
28 in · 711 mm
Shipping weight (approx.)
450 lb · 204 kg
Water connections
2 in male copper sweat (potable water) ; 2 in NPT male (boiler)
Heat exchanger
Copper coils carrying potable water, immersed in boiler water (instantaneous)
Build and warranty
Drain valve
Brass
Limited warranty, tank
15 years
Limited warranty, parts
2 years

Manufacturer data. Detailed sources at the bottom of the page.

09 · Same family

The size below and above

10 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Do I need a boiler?

Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 120 gallons enough for?

It delivers 3,929 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).

11 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Thermo 2000 TurboMax flyer EN · www.thermo2000.com
  2. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  3. Thermo 2000 TurboMax Use & Care manual · www.thermo2000.com
  4. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  5. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  6. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  7. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  8. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  9. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A 120 US gallon indirect water heater with 2 1/2 in connections for commercial kitchens, laundries and hotels

In a restaurant kitchen, a commercial laundry or a hotel, hot water is used in large volumes and at high flow. When the building is heated by an electric boiler, the Thermo 2000 TurboMax 120-9A 125 indirect water heater can handle production: a 120 US gallon tank, a 58.9 sq. ft. copper coil system, a maximum domestic hot water flow of 27 gpm and 2 1/2 in male sweat potable water connections. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

2 1/2 in connections for high flows

The diameter of the potable water connections is the first visible difference of this model. At 2 1/2 in, the tank connects to a large-diameter commercial distribution, without a reduction at the outlet, which limits pressure losses when several appliances draw hot water at the same time. The boiler connection is 2 in NPT male. According to Thermo 2000, the high-exchange-capacity copper coil system heats water instantly, as it passes through the exchanger.

Manufacturer’s data

  • Capacity: 120 US gallons
  • Heat exchanger: copper coils, exchange surface of 58.9 sq. ft.
  • At 110 °F: maximum exchange capacity of 1,165,000 BTU/h (341 kW); 2,122 US GPH first hour; 2,002 US GPH continuous
  • At 140 °F: maximum exchange capacity of 820,000 BTU/h (240 kW); 1,038 US GPH first hour; 990 US GPH continuous
  • At 160 °F: maximum exchange capacity of 545,000 BTU/h (160 kW); 569 US GPH first hour; 549 US GPH continuous
  • Conditions: domestic cold water at 40 °F, boiler water at 180 °F
  • Maximum domestic hot water flow: 27 gpm
  • Maximum pressure: 125 psi
  • Connections: potable water 2 1/2 in male sweat; boiler 2 in NPT male
  • Dimensions: height 76 3/4 in, diameter 28 in
  • Weight: 450 lb

Hotels, laundries and kitchens: three peak profiles

A hotel has a very sharp peak in the morning, when guests shower before checking out, then another in the evening. A commercial laundry fills several washers at once, several times an hour. A restaurant kitchen draws hot water almost continuously during service, for the pot sink and cleaning. These three profiles have one thing in common: high flow over an extended period. That is where the 27 gpm maximum flow and the 2 1/2 in connections make sense. Thermo 2000 specifies that the values must be reduced for high-temperature and continuous-flow applications, which is precisely the case for a laundry or a kitchen; we take this into account in the sizing.

A 125 psi maximum pressure to respect

The maximum pressure of this model is 125 psi. In a commercial building, supply pressure can be high, especially when a booster pump feeds the upper floors. We measure the pressure at the water entrance and install a pressure-reducing valve upstream of the tank when needed. The relief valve is chosen according to this maximum pressure, and an expansion tank absorbs the expansion of the heated water. If the measured pressure does not allow this limit to be respected reliably, we tell you before ordering and review the configuration with you.

The electric boiler sets the real output

The published exchange capacities, up to 1,165,000 BTU/h (341 kW) for water at 110 °F, describe what the exchanger can transfer at most. With an electric boiler, the real continuous output depends on the capacity that the building’s electrical service can devote to hot water. Commercial uses often require hotter water: at 140 °F, the table shows 1,038 US GPH in the first hour and 990 US GPH continuous; at 160 °F, 569 US GPH and 549 US GPH, always at full exchange capacity. We establish with you the available capacity and the expected output before any order.

Installation in the mechanical room

The TurboMax 120-9A 125 weighs 450 lb empty and is 76 3/4 in high and 28 in in diameter. We plan the delivery route, free height, floor capacity and proximity to a drain. A thermostatic mixing valve at the outlet delivers the right temperature to hand basins and showers, while appliances that require hotter water are supplied accordingly. The tank drain valve, supplied as standard, is used during yearly maintenance scheduled outside opening hours.

Manufacturer’s warranty

Thermo 2000 offers a 10-year commercial warranty, a 15-year residential warranty and a 2-year warranty on mechanical components. The category applicable to your establishment is confirmed in writing with the quote.

Installation of the Thermo 2000 TurboMax 120-9A 125 by AirGreen

AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this commercial indirect water heater, our service includes:

  • analysis of consumption peaks, supply pressure and the electric boiler’s capacity;
  • assessment of the mechanical room, floor, drain and delivery route;
  • removal of the old equipment;
  • connecting the potable water in 2 1/2 in, with pressure-reducing valve, thermostatic mixing valve and isolation valves;
  • connecting to the boiler in 2 in, with circulator, check valve and air vents;
  • the relief valve, its discharge pipe and the expansion tank;
  • wiring the controls, commissioning and a yearly maintenance plan.

We work with restaurant owners, hoteliers and property managers in Montreal, Laval, Longueuil, Old Montreal, Dorval, Brossard, Saint-Hyacinthe, Blainville and across the South Shore and the North Shore. The on-site estimate is free, the quote is written and financing is available.

Request your free quote for the Thermo 2000 TurboMax 120-9A 125. Describe your establishment, your appliances and your boiler: we will propose a clear configuration suited to your peaks.