THERMO 2000 TURBOMAX80-5A Indirect Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TURBOMAX80-5A
303 L80 US gal of storage
2,199 Lof hot water in the first hour
15 yrstank warranty
Talk to an expert · 514 316-2973
15-year tank warranty, 2-year parts2 in male copper sweat connections
01 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 2,199 L

An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

02 · Why this model

What sets the Thermo 2000 TurboMax 80-5A-150 apart

Instant

No stored potable water

Potable water runs through copper coils and is heated on demand: the 80 gal tank holds boiler water, not the water you drink.

32.7 sq ft

Heat-transfer area

The copper coils provide 32.7 sq ft of exchange surface for a maximum domestic hot water flow of 15 gpm, per Thermo 2000.

ASME

'A' version

Per Thermo 2000's spec sheet, 'A' models (80A and 120A) meet ASME Section VIII Div. 1, with a 50 psi relief valve.

2 in

Potable connection

The 80-5A has a 2 in potable water connection versus 1-1/2 in on the 80-5, with identical performance.

15 yrs

Residential warranty

Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.

03 · How it works

The boiler heats the water without ever touching it

Boilerheat sourceboiler waterHeat exchangertwo separate circuitsHot waterto the houseCold waterfrom the mains
  1. When the tank calls for heat, its control starts the boiler loop.
  2. Boiler water and drinking water flow in two separate circuits: heat passes through the exchanger wall.
  3. No electric element: all the heat comes from the boiler that already heats the house.
04 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 75.38 in tall (1915 mm), 24 in across (610 mm), about 317 lb shipping weight. The clearances the manufacturer requires are checked on site.

05 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

06 · Installation

What the spot needs, and who does what

A boilerIts ratings are published with a 455,000 BTU/h boiler. The heating contractor checks yours.
Boiler loopCirculator or zone valve, with the tank control wired to the boiler.
2 in male copper sweat waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

07 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. With the boilerThe heating contractor checks the loop, circulator and tank control during the boiler service.
08 · Spec sheet

Every figure, with its source

Capacity and performance
Model
TURBOMAX80-5A
Capacity
80 US gal · 303 L
First-hour rating
581 US gal · 2,199 L
Continuous draw
549 US gal/h · 2,078 L/h
Reference boiler
455,000 BTU/h
Recovery
549 US gal/h · 2078 L/h
Dimensions and connections
Height
75.38 in · 1,915 mm
Diameter
24 in · 610 mm
Shipping weight (approx.)
317 lb · 144 kg
Water connections
2 in male copper sweat (potable water) ; 1 1/2 in NPT male (boiler)
Heat exchanger
Copper coils carrying potable water, immersed in boiler water (instantaneous)
Build and warranty
Drain valve
Brass
Limited warranty, tank
15 years
Limited warranty, parts
2 years

Manufacturer data. Detailed sources at the bottom of the page.

09 · Same family

The size below and above

80 US gal75.38 in tallYou are here
120 US gal77.44 in tallSee the larger one
10 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Do I need a boiler?

Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 80 gallons enough for?

It delivers 2,199 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).

11 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Thermo 2000 TurboMax flyer EN · www.thermo2000.com
  2. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  3. Thermo 2000 TurboMax Use & Care manual · www.thermo2000.com
  4. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  5. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  6. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  7. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  8. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  9. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

An 80 US gallon indirect water heater with 2 in potable water connections for small businesses and new construction

In a café, a daycare, a clinic or a small new building heated by an electric boiler, hot water must circulate through a longer and busier network than in a home. The Thermo 2000 TurboMax 80-5A indirect water heater combines an 80 US gallon tank, a 32.7 sq. ft. copper coil system and 2 in male sweat potable water connections, suited to larger-diameter distribution. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

What 2 in connections change

The diameter of the potable water connections determines that of the piping leaving the tank. With 2 in connections, the TurboMax 80-5A connects directly to a commercial distribution of good diameter, without a reduction at the outlet. In a building where several sinks, a dishwasher and hand basins are supplied at the same time, properly sized piping limits pressure losses and temperature swings at the tap. The model’s maximum domestic hot water flow is 15 gpm; we design the network around that value and the fixtures to be served.

Manufacturer’s data

  • Capacity: 80 US gallons
  • Heat exchanger: high-exchange-capacity copper coils, surface of 32.7 sq. ft.
  • At 110 °F: maximum exchange capacity of 645,000 BTU/h (189 kW); 1,189 US GPH first hour; 1,109 US GPH continuous
  • At 140 °F: maximum exchange capacity of 455,000 BTU/h (133 kW); 581 US GPH first hour; 549 US GPH continuous
  • At 160 °F: maximum exchange capacity of 300,000 BTU/h (88 kW); 316 US GPH first hour; 302 US GPH continuous
  • Conditions: domestic cold water at 40 °F, boiler water at 180 °F
  • Maximum domestic hot water flow: 15 gpm
  • Maximum pressure: 150 psi
  • Connections: potable water 2 in male sweat; boiler 1 1/2 in NPT male
  • Dimensions: height 74 3/4 in, diameter 24 in
  • Weight: 317 lb

Restaurants, cafés and daycares

The consumption profile of a small business has nothing in common with that of a home. In a café, the pot sink and dishwasher run continuously at busy times. In a daycare, handwashing, dishes and cleaning are spread over the whole day, with peaks at lunch. In a clinic, the hand basins run from morning to night. The TurboMax 80-5A meets these profiles with an 80 US gallon reserve that absorbs the peaks and an exchanger that keeps production going as long as the electric boiler supplies the necessary heat.

Higher temperatures and user safety

Several commercial uses require hotter water than a shower. Thermo 2000’s table shows, for water at 140 °F, 581 US GPH in the first hour and 549 US GPH continuous; at 160 °F, 316 US GPH and 302 US GPH. The manufacturer specifies that these values must be reduced for high-temperature and continuous-flow applications. When water is produced at a high temperature, a thermostatic mixing valve brings the water delivered to hand basins and washrooms back to a safe temperature, which matters especially in a daycare.

Real output with an electric boiler

The published flows assume that the boiler supplies the exchanger’s maximum exchange capacity, up to 645,000 BTU/h (189 kW) for water at 110 °F. With an electric boiler, the available capacity depends on the building’s electrical service, and it is that capacity that sets the real continuous output. We establish this capacity from the start, then tell you the expected output. If a gap remains with your needs, we discuss it before ordering rather than after commissioning.

New construction: planning the mechanical room

In a new project, the best time to plan hot water is at the drawing stage. The TurboMax 80-5A is 74 3/4 in high and 24 in in diameter and weighs 317 lb empty. You need enough free height, taking the top fittings into account, a floor able to carry the filled tank, a nearby drain and clear access for service. The boiler connection is 1 1/2 in NPT male. The tank drain valve, supplied as standard, makes yearly maintenance easier.

Planned maintenance in a commercial setting

In a business, a hot water outage is costly: a kitchen cannot open, a daycare has to make other arrangements. We recommend a yearly visit scheduled outside opening hours. It includes a test of the relief valve, a check of the circulator, the control and the mixing valve, an inspection of the fittings and a partial draining through the tank drain valve when the water carries sediment.

Manufacturer’s warranty

Thermo 2000 provides a 10-year commercial warranty, a 15-year residential warranty and a 2-year warranty on mechanical components. The warranty applicable to your building is confirmed in writing with the quote.

Installation of the Thermo 2000 TurboMax 80-5A by AirGreen

AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our service includes:

  • analysis of the consumption profile and of the electric boiler’s capacity;
  • coordination with the project drawings or assessment of the existing mechanical room;
  • removal of old units, where applicable;
  • connecting the potable water in 2 in, with thermostatic mixing valve and isolation valves;
  • connecting to the boiler in 1 1/2 in, with circulator, check valve and air vent;
  • the relief valve, its discharge pipe and the expansion tank;
  • wiring the control, commissioning and a yearly maintenance plan.

We work with business owners, developers and property managers in Montreal, Laval, Longueuil, Brossard, Boucherville, Saint-Bruno, Mirabel, Terrebonne and the entire South Shore and North Shore. Free on-site estimate, written quote and financing available.

Request your free quote for the Thermo 2000 TurboMax 80-5A. Send us your drawings or a few photos of your mechanical room: we will propose a clear, compliant installation.