THERMO 2000 TURBOMAX30-3 Indirect Water Heater (30 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TURBOMAX30-3
114 L30 US gal of storage
1,279 Lof hot water in the first hour
15 yrstank warranty
Talk to an expert · 514 316-2973
15-year tank warranty, 2-year parts1 1/4 in male copper sweat connections
01 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 1,279 L

An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

02 · Why this model

What sets the Thermo 2000 TurboMax 30-3 apart

Instant

No stored potable water

Potable water runs through copper coils and is heated on demand: the 30 gal tank holds boiler water, not the water you drink.

19.6 sq ft

Heat-transfer area

The copper coils provide 19.6 sq ft of exchange surface for a maximum domestic hot water flow of 9 gpm, per Thermo 2000.

18 in

Compact diameter

At 18 in wide and 170 lb, it is the narrowest TurboMax, suited to a mechanical closet.

15 yrs

Residential warranty

Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.

03 · How it works

The boiler heats the water without ever touching it

Boilerheat sourceboiler waterHeat exchangertwo separate circuitsHot waterto the houseCold waterfrom the mains
  1. When the tank calls for heat, its control starts the boiler loop.
  2. Boiler water and drinking water flow in two separate circuits: heat passes through the exchanger wall.
  3. No electric element: all the heat comes from the boiler that already heats the house.
04 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 59.69 in tall (1516 mm), 18 in across (457 mm), about 170 lb shipping weight. The clearances the manufacturer requires are checked on site.

05 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

06 · Installation

What the spot needs, and who does what

A boilerIts ratings are published with a 270,000 BTU/h boiler. The heating contractor checks yours.
Boiler loopCirculator or zone valve, with the tank control wired to the boiler.
1 1/4 in male copper sweat waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

07 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. With the boilerThe heating contractor checks the loop, circulator and tank control during the boiler service.
08 · Spec sheet

Every figure, with its source

Capacity and performance
Model
TURBOMAX30-3
Capacity
30 US gal · 114 L
First-hour rating
338 US gal · 1,279 L
Continuous draw
326 US gal/h · 1,234 L/h
Reference boiler
270,000 BTU/h
Recovery
326 US gal/h · 1234 L/h
Dimensions and connections
Height
59.69 in · 1,516 mm
Diameter
18 in · 457 mm
Shipping weight (approx.)
170 lb · 77 kg
Water connections
1 1/4 in male copper sweat (potable water) ; 1 1/4 in NPT male (boiler)
Heat exchanger
Copper coils carrying potable water, immersed in boiler water (instantaneous)
Build and warranty
Drain valve
Brass
Limited warranty, tank
15 years
Limited warranty, parts
2 years

Manufacturer data. Detailed sources at the bottom of the page.

09 · Same family

The size below and above

30 US gal59.69 in tallYou are here
50 US gal60.69 in tallSee the larger one
10 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Do I need a boiler?

Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 30 gallons enough for?

It delivers 1,279 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).

11 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Thermo 2000 TurboMax flyer EN · www.thermo2000.com
  2. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  3. Thermo 2000 TurboMax Use & Care manual · www.thermo2000.com
  4. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  5. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  6. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  7. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  8. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  9. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A compact 30 US gallon indirect water heater for small homes and condos heated by an electric boiler

In a condo, a bungalow or a townhouse heated by an electric boiler and radiant floors, the mechanical space often comes down to a closet. The Thermo 2000 TurboMax 30-3 indirect water heater was designed for this kind of place: a 30 US gallon tank only 18 in in diameter, with a high-exchange-capacity copper coil system that heats domestic water instantly, according to the manufacturer. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

This model lets the electric boiler that already heats the home take over hot water production, and frees the space taken by a separate electric water heater.

A format designed for small spaces

At 59 3/4 in high, 18 in in diameter and 170 lb, the TurboMax 30-3 fits where a wider tank will not: a service closet, a corner of the laundry room, a condo’s mechanical room. It is installed beside the boiler, which keeps the piping short and simple. We still check the clearances needed for the fittings, the relief valve and the drain valve, as well as access to a drain or a drain pan.

How the TurboMax produces hot water

The TurboMax is an indirect water heater: it is connected to the electric boiler, whose heating water supplies its energy. According to Thermo 2000, its high-exchange-capacity copper coil system heats water instantly: domestic water is heated as it passes through the exchanger. The difference between first-hour output and continuous output, in the table below, corresponds to the energy already stored in the tank at the start of use.

Manufacturer’s data

  • Capacity: 30 US gallons
  • Heat exchanger: copper coils, exchange surface of 19.6 sq. ft.
  • Domestic hot water at 110 °F: maximum exchange capacity of 380,000 BTU/h (111 kW); 683 US GPH first hour; 653 US GPH continuous
  • Domestic hot water at 140 °F: maximum exchange capacity of 270,000 BTU/h (79 kW); 338 US GPH first hour; 326 US GPH continuous
  • Domestic hot water at 160 °F: maximum exchange capacity of 180,000 BTU/h (53 kW); 186 US GPH first hour; 181 US GPH continuous
  • Conditions: domestic cold water at 40 °F and boiler water at 180 °F
  • Maximum domestic hot water flow: 9 gpm
  • Maximum pressure: 150 psi
  • Connections: potable water 1 1/4 in male sweat; boiler 1 1/4 in NPT male
  • Dimensions: height 59 3/4 in, diameter 18 in
  • Weight: 170 lb

Maximum exchange capacity and your boiler’s real output

The manufacturer’s figures are impressive for a 30 US gallon tank, and they need to be read correctly. They show what the exchanger can transfer at most, when the boiler supplies it with up to 380,000 BTU/h (111 kW) for water at 110 °F. A residential electric boiler supplies much less. With it, the TurboMax 30-3 heats water the same way, but its continuous output is limited by the boiler’s capacity, not by the exchanger.

Thermo 2000 also specifies that these values must be reduced for high-temperature and continuous-flow applications. During the assessment, we start from your boiler’s capacity and your habits to tell you what you will really get at the tap, rather than quoting the best line of the table.

Who the TurboMax 30-3 is for

This model suits a couple or a small family in a condo or a compact home heated by an electric boiler. It is also relevant in a renovation project where baseboards are replaced by radiant floors and where heating and hot water are to be grouped in a single room. For a home with several bathrooms or a large tub, a larger TurboMax is more appropriate; we compare the options with you.

Flow, temperature and comfort

The maximum domestic hot water flow of the TurboMax 30-3 is 9 gpm. It is the value that guides the piping diameter and the number of fixtures that can be supplied at the same time; we take it into account in the design. We generally recommend adding a thermostatic mixing valve at the outlet, especially if water is produced at 140 °F or more: it delivers a safe, steady temperature at the taps. The control is connected to the electric boiler with hot water priority, so the boiler devotes a few minutes to it before returning to heating.

Manufacturer’s warranty

Thermo 2000 offers a 15-year residential warranty and a 10-year commercial warranty, as well as a 2-year warranty on mechanical components. The terms that apply to your installation are confirmed in writing with the quote.

Installation of the Thermo 2000 TurboMax 30-3 by AirGreen

AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work, which allows us to handle the piping as well as the electrical controls. Our work includes:

  • assessment of the electric boiler, its capacity and the available space;
  • removal and disposal of the old water heater;
  • connecting the potable water in 1 1/4 in, with thermostatic mixing valve and shut-off valves;
  • connecting to the boiler in 1 1/4 in, with circulator or zone valve, check valve and air vent;
  • the relief valve and its discharge pipe to a drain;
  • wiring the control and setting hot water priority;
  • commissioning and maintenance advice, including periodic draining through the tank drain valve.

We serve Montreal, Laval, Longueuil, Verdun, Saint-Lambert, Brossard, Boisbriand, Mascouche and the entire South Shore and North Shore. Free on-site estimate, written quote and financing available.

Request your free quote for the Thermo 2000 TurboMax 30-3. A photo of your boiler, its rating plate and the planned closet is all we need to confirm feasibility.