No stored potable water
Potable water runs through copper coils and is heated on demand: the 50 gal tank holds boiler water, not the water you drink.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Potable water runs through copper coils and is heated on demand: the 50 gal tank holds boiler water, not the water you drink.
The copper coils provide 19.6 sq ft of exchange surface for a maximum domestic hot water flow of 9 gpm, per Thermo 2000.
It uses the 30-3's 19.6 sq ft coil in a 50 gal tank, adding stored energy for the first hour (346 gal at 140 °F vs 338).
Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.
It travels upright. Measure the ceiling at the spot and the narrowest door on the way.
Unit: 60.69 in tall (1542 mm), 22 in across (559 mm), about 212 lb shipping weight. The clearances the manufacturer requires are checked on site.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, coordination of the work.
HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 1,310 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
If your home is heated by an electric boiler, the unit that already produces hot water for the floors or radiators can also heat the water for the showers. The Thermo 2000 TurboMax 50-3 indirect water heater makes that link: a 50 US gallon tank fitted with a high-exchange-capacity copper coil system that, according to the manufacturer, heats water instantly. AirGreen installs it in homes in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
It is a family format: enough reserve for the morning and evening peaks, a reasonable footprint in the basement and an installation that ties into the existing boiler.
A home heated by an electric boiler often also has a separate electric water heater, with its own circuit and its own elements to replace one day. The TurboMax 50-3 groups both functions around a single heating unit. The boiler, already sized for the house, supplies the energy; the indirect tank turns it into domestic hot water, without the heating water and the potable water ever mixing. The day the old water heater reaches the end of its life is often the best time to make this change.
In the manufacturer’s table, first-hour output exceeds continuous output: 703 US GPH versus 653 US GPH for water at 110 °F. This gap comes from the energy already stored in the tank when the demand begins. In practice, this reserve covers the start of the peak: the first morning shower, the children’s bath, a laundry load started at the same time. After that, output depends on what the boiler supplies continuously.
Thermo 2000 gives its values for three domestic hot water temperatures. The 110 °F column corresponds to the mixed water of a shower. The 140 °F column corresponds to hotter produced water, brought back to a safe temperature with a thermostatic mixing valve. The 160 °F column concerns particular uses. The hotter the water required, the lower the hourly output: at 140 °F, the TurboMax 50-3 delivers 346 US GPH in the first hour, and 190 US GPH at 160 °F. We set the temperature according to your use, keeping comfort and safety in mind.
The published flows assume that the boiler supplies the exchanger’s maximum exchange capacity, that is 380,000 BTU/h (111 kW) at 110 °F. A residential electric boiler supplies much less. The tank then works the same way, but continuous output follows the boiler’s capacity. The manufacturer adds that these values must be reduced for high-temperature and continuous-flow applications. We therefore do the calculation from your boiler, and we usually program hot water priority so that the boiler devotes itself to the tank for a few minutes before returning to heating.
At 60 3/4 in high and 22 in in diameter, the TurboMax 50-3 is installed beside the boiler in most basements. It weighs 212 lb empty; once filled, it must sit on a solid, level floor, near a drain. Potable water connects in 1 1/2 in male sweat and the boiler in 1 1/4 in NPT male. The tank drain valve, supplied as standard, is used during periodic maintenance. The 9 gpm maximum domestic hot water flow guides the choice of distribution piping.
Thermo 2000 provides a 15-year residential warranty, a 10-year commercial warranty and a 2-year warranty on mechanical components. The terms applicable to your home are confirmed in writing with the quote.
AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our service includes:
We serve Montreal, Laval, Longueuil, Ahuntsic, Pierrefonds, Greenfield Park, Saint-Constant, Lorraine and the entire South Shore and North Shore. The on-site estimate is free, the quote is written and financing is available.
Request your free quote for the Thermo 2000 TurboMax 50-3. Send us your boiler’s rating plate and a photo of your current water heater: we will explain what the TurboMax will deliver in your home.