No stored potable water
Potable water runs through copper coils and is heated on demand: the 50 gal tank holds boiler water, not the water you drink.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Potable water runs through copper coils and is heated on demand: the 50 gal tank holds boiler water, not the water you drink.
The copper coils provide 32.7 sq ft of exchange surface for a maximum domestic hot water flow of 15 gpm, per Thermo 2000.
The 32.7 sq ft coil (the '5') raises maximum flow to 15 gpm, versus 9 gpm for the same-size 50-3.
Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.
It travels upright. Measure the ceiling at the spot and the narrowest door on the way.
Unit: 60.69 in tall (1542 mm), 22 in across (559 mm), about 230 lb shipping weight. The clearances the manufacturer requires are checked on site.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, coordination of the work.
HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 2,154 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
Some homes are short not so much on volume as on flow. Two bathrooms used at the same time, a multi-jet shower, a tub filling while the washing machine runs: it is instantaneous flow that makes the difference. The Thermo 2000 TurboMax 50-5 indirect water heater pairs a 50 US gallon tank with a 32.7 sq. ft. copper coil system and a maximum domestic hot water flow of 15 gpm. It is fed by an electric boiler. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
The TurboMax 50-5 keeps the footprint of a 50 US gallon tank, at 60 3/4 in high and 22 in in diameter, but it houses an exchange surface of 32.7 sq. ft. Thermo 2000 describes this high-exchange-capacity copper coil system as a way to heat water instantly: domestic water is heated as it passes through the exchanger. The larger the surface, the more heat the exchanger can transfer at once, provided the boiler supplies it.
The maximum domestic hot water flow shows how much hot water can leave the tank at a given moment. With 15 gpm, the TurboMax 50-5 is designed to supply several fixtures at the same time, which makes it a good candidate for a home with several bathrooms or a multi-jet shower. Thermo 2000 specifies that these values must be reduced for high-temperature and continuous-flow applications; we take this into account when sizing the piping and setting the thermostatic mixing valve.
This model suits a large home heated by an electric boiler, where several people get ready at the same time in the morning. It also suits small businesses heated the same way: a hair salon rinsing continuously, a physiotherapy clinic with a few showers, a yoga studio. In these cases, it is not the reserve that is lacking, but the ability to deliver a lot of hot water at the same time.
For a home where hot water is mostly used one appliance at a time, a smaller exchanger is generally enough. We compare the options with you based on your real habits.
The published exchange capacities, up to 645,000 BTU/h (189 kW) for water at 110 °F, describe what the exchanger can transfer at most. A residential electric boiler supplies much less, and it is the boiler that sets the real continuous output. In a home, the TurboMax 50-5 exchanger therefore rarely works at full capacity; its advantage shows mainly in its 15 gpm maximum flow. In a business equipped with a larger electric boiler, the exchanger can make more of it. In both cases, we check the electrical service and the available capacity before proposing a configuration.
Potable water connects in 1 1/2 in male sweat and the boiler in 1 1/4 in NPT male. The tank weighs 230 lb empty and, once filled, must sit on a solid, level floor, near a drain. Its 22 in diameter lets it take its place beside the boiler in most mechanical rooms. The tank drain valve, supplied as standard, simplifies maintenance. The control is connected to the boiler with hot water priority.
One visit per year keeps the system reliable: a test of the relief valve, a check of the circulator and the control, an inspection of the fittings and a partial draining through the tank drain valve when the water carries sediment. In a business where hot water is used all day, we schedule this visit outside opening hours, so service to your customers is never interrupted.
Thermo 2000 offers a 15-year residential warranty, a 10-year commercial warranty and a 2-year warranty on mechanical components. The warranty that applies to your installation is confirmed in writing with the quote.
AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. Our work includes:
We serve homes and businesses in Montreal, Laval, Longueuil, Outremont, Mount Royal, Boucherville, Blainville, L’Assomption and across the South Shore and the North Shore. Free on-site estimate, written quote and financing available.