No stored potable water
Potable water runs through copper coils and is heated on demand: the 80 gal tank holds boiler water, not the water you drink.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Potable water runs through copper coils and is heated on demand: the 80 gal tank holds boiler water, not the water you drink.
The copper coils provide 32.7 sq ft of exchange surface for a maximum domestic hot water flow of 15 gpm, per Thermo 2000.
Its 80 gal of boiler water yields 581 gal first hour at 140 °F at full exchange capacity.
Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.
It travels upright. Measure the ceiling at the spot and the narrowest door on the way.
Unit: 75.38 in tall (1915 mm), 24 in across (610 mm), about 308 lb shipping weight. The clearances the manufacturer requires are checked on site.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, coordination of the work.
HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 2,199 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
In a duplex, a triplex or a large home heated by an electric boiler, hot water is shared between several households or several floors, and the peaks overlap. The Thermo 2000 TurboMax 80-5 indirect water heater answers this situation with an 80 US gallon tank, a 32.7 sq. ft. copper coil system and a maximum domestic hot water flow of 15 gpm. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
An electric boiler is sized to heat the building, and its capacity is limited by the electrical service. That is why tank volume matters so much in a plex: it stores energy during off-peak hours and releases it when everyone opens the tap. The manufacturer’s table shows this clearly. For water at 110 °F, first-hour output reaches 1,189 US GPH, versus 1,109 US GPH continuous; the gap comes from the energy already stored in the tank. With a modest boiler, this reserve becomes the first line of defence against a lukewarm shower.
In a duplex or triplex whose electric boiler serves all the units, a single indirect tank can replace several electric water heaters spread across the basements. The owner then has only one hot water unit to maintain, and the freed space can be used for something else. In a multigenerational home, the principle is the same: one tank, one heat source, and a reserve large enough that the two households do not have to organize themselves around hot water. We check with you the requirements that apply to distribution between units before proposing this configuration.
The first-hour and continuous output values assume that the boiler supplies the exchanger’s maximum exchange capacity: 645,000 BTU/h (189 kW) for water at 110 °F. A plex electric boiler generally supplies much less. With it, the TurboMax 80-5 works the same way, but continuous output follows the boiler’s real capacity. Thermo 2000 also specifies that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the output you can expect with your boiler, not the best line of the table.
The TurboMax 80-5 is 74 3/4 in high and 24 in in diameter. In plex basements, where the height under the beams is often limited by piping and ducts, this measurement must be checked before ordering, adding the space needed for the top fittings. The tank weighs 308 lb empty: we plan the route down the stairs and a solid, level floor near a drain.
Potable water and the boiler both connect in 1 1/2 in, male sweat on the potable water side and NPT male on the boiler side. When hot water must travel several floors, we add a recirculation loop when needed so it reaches distant taps quickly, and a thermostatic mixing valve to deliver a safe temperature. The control is connected to the electric boiler with hot water priority. The tank drain valve, supplied as standard, is used for yearly maintenance.
The temperature at which water is produced changes the quantity available. At 140 °F, the TurboMax 80-5 gives 581 US GPH in the first hour and 549 US GPH continuous; at 160 °F, 316 US GPH and 302 US GPH. In a plex, we choose the production temperature according to real uses, knowing that every increase reduces hourly output, then the thermostatic mixing valve ensures a safe temperature before the water reaches the units. This setting is discussed with you according to the occupants’ ages and the length of the piping.
Thermo 2000 offers a 15-year residential warranty, a 10-year commercial warranty and a 2-year warranty on mechanical components. The category applicable to your building is confirmed in writing with the quote.
AirGreen is a family business established in Montreal, active in heating, ventilation and air conditioning for more than fifteen years and holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our work includes:
We serve Montreal, Laval, Longueuil, Rosemont, Villeray, Saint-Hubert, Lachine, Sainte-Rose and the entire South Shore and North Shore. The on-site estimate is free, the quote is written and financing is available.
Request your free quote for the Thermo 2000 TurboMax 80-5. Tell us how many units share the boiler and send a photo of its rating plate: we will propose a clear configuration.