THERMO 2000 TURBOMAX80-5 Indirect Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TURBOMAX80-5
303 L80 US gal of storage
2,199 Lof hot water in the first hour
15 yrstank warranty
Talk to an expert · 514 316-2973
15-year tank warranty, 2-year parts1 1/2 in male copper sweat connections
01 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 2,199 L

An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

02 · Why this model

What sets the Thermo 2000 TurboMax 80-5 apart

Instant

No stored potable water

Potable water runs through copper coils and is heated on demand: the 80 gal tank holds boiler water, not the water you drink.

32.7 sq ft

Heat-transfer area

The copper coils provide 32.7 sq ft of exchange surface for a maximum domestic hot water flow of 15 gpm, per Thermo 2000.

80 gal

Energy reserve

Its 80 gal of boiler water yields 581 gal first hour at 140 °F at full exchange capacity.

15 yrs

Residential warranty

Thermo 2000 covers the tank and copper coils for 15 years in residential use (10 years commercial) and mechanical parts for 2 years.

03 · How it works

The boiler heats the water without ever touching it

Boilerheat sourceboiler waterHeat exchangertwo separate circuitsHot waterto the houseCold waterfrom the mains
  1. When the tank calls for heat, its control starts the boiler loop.
  2. Boiler water and drinking water flow in two separate circuits: heat passes through the exchanger wall.
  3. No electric element: all the heat comes from the boiler that already heats the house.
04 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 75.38 in tall (1915 mm), 24 in across (610 mm), about 308 lb shipping weight. The clearances the manufacturer requires are checked on site.

05 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

06 · Installation

What the spot needs, and who does what

A boilerIts ratings are published with a 455,000 BTU/h boiler. The heating contractor checks yours.
Boiler loopCirculator or zone valve, with the tank control wired to the boiler.
1 1/2 in male copper sweat waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

07 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. With the boilerThe heating contractor checks the loop, circulator and tank control during the boiler service.
08 · Spec sheet

Every figure, with its source

Capacity and performance
Model
TURBOMAX80-5
Capacity
80 US gal · 303 L
First-hour rating
581 US gal · 2,199 L
Continuous draw
549 US gal/h · 2,078 L/h
Reference boiler
455,000 BTU/h
Recovery
549 US gal/h · 2078 L/h
Dimensions and connections
Height
75.38 in · 1,915 mm
Diameter
24 in · 610 mm
Shipping weight (approx.)
308 lb · 140 kg
Water connections
1 1/2 in male copper sweat (potable water) ; 1 1/2 in NPT male (boiler)
Heat exchanger
Copper coils carrying potable water, immersed in boiler water (instantaneous)
Build and warranty
Drain valve
Brass
Limited warranty, tank
15 years
Limited warranty, parts
2 years

Manufacturer data. Detailed sources at the bottom of the page.

09 · Same family

The size below and above

10 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Do I need a boiler?

Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 80 gallons enough for?

It delivers 2,199 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).

11 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Thermo 2000 TurboMax flyer EN · www.thermo2000.com
  2. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  3. Thermo 2000 TurboMax Use & Care manual · www.thermo2000.com
  4. Thermo 2000 TurboMax Specifications · www.thermo2000.com
  5. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  6. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  7. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  8. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  9. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

An 80 US gallon indirect water heater for plexes and large homes heated by an electric boiler

In a duplex, a triplex or a large home heated by an electric boiler, hot water is shared between several households or several floors, and the peaks overlap. The Thermo 2000 TurboMax 80-5 indirect water heater answers this situation with an 80 US gallon tank, a 32.7 sq. ft. copper coil system and a maximum domestic hot water flow of 15 gpm. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

When the reserve matters more than the capacity

An electric boiler is sized to heat the building, and its capacity is limited by the electrical service. That is why tank volume matters so much in a plex: it stores energy during off-peak hours and releases it when everyone opens the tap. The manufacturer’s table shows this clearly. For water at 110 °F, first-hour output reaches 1,189 US GPH, versus 1,109 US GPH continuous; the gap comes from the energy already stored in the tank. With a modest boiler, this reserve becomes the first line of defence against a lukewarm shower.

Manufacturer’s data

  • Capacity: 80 US gallons
  • Heat exchanger: high-exchange-capacity copper coils, surface of 32.7 sq. ft.
  • Domestic hot water at 110 °F: maximum exchange capacity of 645,000 BTU/h (189 kW); 1,189 US GPH first hour; 1,109 US GPH continuous
  • Domestic hot water at 140 °F: maximum exchange capacity of 455,000 BTU/h (133 kW); 581 US GPH first hour; 549 US GPH continuous
  • Domestic hot water at 160 °F: maximum exchange capacity of 300,000 BTU/h (88 kW); 316 US GPH first hour; 302 US GPH continuous
  • Conditions: domestic cold water at 40 °F, boiler water at 180 °F
  • Maximum domestic hot water flow: 15 gpm
  • Maximum pressure: 150 psi
  • Connections: potable water 1 1/2 in male sweat; boiler 1 1/2 in NPT male
  • Dimensions: height 74 3/4 in, diameter 24 in
  • Weight: 308 lb

Plexes and multigenerational homes

In a duplex or triplex whose electric boiler serves all the units, a single indirect tank can replace several electric water heaters spread across the basements. The owner then has only one hot water unit to maintain, and the freed space can be used for something else. In a multigenerational home, the principle is the same: one tank, one heat source, and a reserve large enough that the two households do not have to organize themselves around hot water. We check with you the requirements that apply to distribution between units before proposing this configuration.

Reading the maximum exchange capacity

The first-hour and continuous output values assume that the boiler supplies the exchanger’s maximum exchange capacity: 645,000 BTU/h (189 kW) for water at 110 °F. A plex electric boiler generally supplies much less. With it, the TurboMax 80-5 works the same way, but continuous output follows the boiler’s real capacity. Thermo 2000 also specifies that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the output you can expect with your boiler, not the best line of the table.

A tank 74 3/4 in tall

The TurboMax 80-5 is 74 3/4 in high and 24 in in diameter. In plex basements, where the height under the beams is often limited by piping and ducts, this measurement must be checked before ordering, adding the space needed for the top fittings. The tank weighs 308 lb empty: we plan the route down the stairs and a solid, level floor near a drain.

Connections and distribution

Potable water and the boiler both connect in 1 1/2 in, male sweat on the potable water side and NPT male on the boiler side. When hot water must travel several floors, we add a recirculation loop when needed so it reaches distant taps quickly, and a thermostatic mixing valve to deliver a safe temperature. The control is connected to the electric boiler with hot water priority. The tank drain valve, supplied as standard, is used for yearly maintenance.

Choosing the production temperature

The temperature at which water is produced changes the quantity available. At 140 °F, the TurboMax 80-5 gives 581 US GPH in the first hour and 549 US GPH continuous; at 160 °F, 316 US GPH and 302 US GPH. In a plex, we choose the production temperature according to real uses, knowing that every increase reduces hourly output, then the thermostatic mixing valve ensures a safe temperature before the water reaches the units. This setting is discussed with you according to the occupants’ ages and the length of the piping.

Manufacturer’s warranty

Thermo 2000 offers a 15-year residential warranty, a 10-year commercial warranty and a 2-year warranty on mechanical components. The category applicable to your building is confirmed in writing with the quote.

Installation of the Thermo 2000 TurboMax 80-5 by AirGreen

AirGreen is a family business established in Montreal, active in heating, ventilation and air conditioning for more than fifteen years and holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our work includes:

  • analysis of each unit’s needs and of the electric boiler’s capacity;
  • check of the free height, the delivery route and the floor;
  • removal of the old electric water heaters;
  • connecting the potable water in 1 1/2 in, with thermostatic mixing valve and, if needed, a recirculation loop;
  • connecting to the boiler in 1 1/2 in, with circulator, check valve and air vent;
  • the relief valve, its discharge pipe and the expansion tank;
  • wiring the control, commissioning and a maintenance plan.

We serve Montreal, Laval, Longueuil, Rosemont, Villeray, Saint-Hubert, Lachine, Sainte-Rose and the entire South Shore and North Shore. The on-site estimate is free, the quote is written and financing is available.

Request your free quote for the Thermo 2000 TurboMax 80-5. Tell us how many units share the boiler and send a photo of its rating plate: we will propose a clear configuration.