BRADFORD WHITE RE2H80T10-1NCTT Heat Pump Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: RE2H80T10-1NCTT
303 L80 US gal of storage
333 Lof hot water in the first hour
3.59UEF: 3.59 times more hot water than electricity
Talk to an expert · 514 316-2973
10-year tank warranty, 10-year parts3/4 in NPT connections240 V
01 · Running cost

What it will cost you each year

Pick your household. The math follows your hot water use, at the current Hydro-Québec rate.

$130

per year in heat pump mode, for 186 L of hot water a day

Standard 47 gal electric tank$524
This model, heat pump mode$130

What stays in your pocket over 10 years

Standard tankThis modelGap

The mode changes the bill

How we calculate. Mains water at 7 °C heated to 60 °C (Québec.ca), 75 L per person per day (Natural Resources Canada) or 186 L for the average Québec household. This model: energy ÷ UEF of 3.59. Standard tank: the same energy plus 59 W of standby loss (Bradford White RE250S6). Price: 11.142 ¢/kWh, Rate D second tier in force since April 1, 2026, before tax. UEF is a lab rating: in a cold basement in winter the elements do more of the work, and part of the heat comes from the house heating. Indicative estimate.

02 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 333 L

Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

03 · Why this model

What sets the Bradford White AeroTherm RE2H80T10 apart

3.59

Uniform Energy Factor

Bradford White's Canadian spec sheet lists a UEF of 3.59 for the RE2H80T10, based on the AHRI directory.

88 gal

First-hour rating

The manufacturer lists a first-hour rating of 88 US gallons (333 L).

2–49 °C

Ambient air range

The heat pump runs in ambient air from 2 to 49 °C (35 to 120 °F); outside that range the unit switches to electric mode.

700 cu ft

Minimum room volume

The installation manual requires a room of at least 700 cu ft (19.8 m³), otherwise louvers or a ducting kit are needed.

88 gal

Highest output in the series

With an 88-US-gallon first-hour rating, it is the highest-output RE2H model.

04 · How it works

The same cycle as a wall heat pump, applied to water

1. Room airfan3. Exhaust aircooler, drierHot watertop outletCold waterenters lowcompressor2. Condensergives off heatbackup element
  1. The fan moves room air over the evaporator, where the refrigerant picks up its heat.
  2. The compressor concentrates that heat and gives it to the water in the tank.
  3. When demand climbs or the room leaves the 2.0 to 49.0 °C range, the electric element takes over.
05 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 70.81 in tall (1799 mm), 25 in across (635 mm), about 259 lb shipping weight. The clearances the manufacturer requires are checked on site.

06 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

07 · Installation

What the spot needs, and who does what

240 V circuit4,000 W elements. A dedicated circuit, sized by our electrician.
3/4 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
Condensate drainThe heat pump makes water: you need a floor drain or a pump nearby.
Air around itIt draws its heat from the room air: the volume and clearances the manufacturer requires are checked at the visit.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up and mode setting.

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

08 · Maintenance

A few habits that make it last

  1. Start-up dayMode choice and temperature, with you.
  2. At all timesKeep the air inlet and outlet clear and clean the air filter as the manual says.
  3. Every yearPartial drain to flush sediment, and a test of the relief valve.
  4. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
09 · Spec sheet

Every figure, with its source

Capacity and performance
Model
RE2H80T10-1NCTT
Capacity
80 US gal · 303 L
First-hour rating
88 US gal · 333 L
Uniform energy factor (UEF)
3.59
Recovery
6 US gal/h · 23 L/h
Heat pump air range
2.0 – 49.0 °C
Electrical
Supply
240 V, single phase
Element
4,000 W × 2
Element type
Screw-in
Dimensions and connections
Height
70.81 in · 1,799 mm
Diameter
25 in · 635 mm
Shipping weight (approx.)
259 lb · 117 kg
Water connections
3/4 in NPT
Build and warranty
Inner lining
Vitraglas with Microban
Drain valve
Brass
Limited warranty, tank
10 years
Limited warranty, parts
10 years

Manufacturer data. Detailed sources at the bottom of the page.

10 · Same family

The size below and above

65 US gal63.75 in tallSee the smaller one
80 US gal70.81 in tallYou are here
11 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Does it work in a basement in winter?

Yes, as long as the room air stays between 2.0 and 49.0 °C. In a heated basement, part of the heat it captures comes from the house heating. Outside its range, it switches to the electric elements.

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 80 gallons enough for?

It delivers 333 L of hot water in the first hour. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).

12 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White AeroTherm Hybrid Electric HPWH spec sheet C1902-0725 CANADA · docs.bradfordwhite.com
  2. BPA HPWH Qualified Products List v80 · www.bpa.gov
  3. Hydro-Québec, rate grid, Rate D in force April 1, 2026 (7.065 ¢ and 11.142 ¢/kWh).
  4. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  5. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  6. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  7. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  8. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A large hot water reserve for very busy homes, heated mostly by a heat pump

Two full bathrooms, teenagers showering one after another, a large bath in the evening and loads of laundry almost every day: in this kind of home, an ordinary electric tank quickly runs out of reserve. The Bradford White RE2H80T10-1NCTT heat pump water heater meets that reality with a tank of 80 US gallons (67 imperial gallons, 303 L) and an integrated heat pump that produces most of the heat from the room air. It is the largest size in the Bradford White heat pump line that we offer, and AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

It suits a tank replacement in a large family home as well as new construction or a major renovation, where a mechanical room suited to a unit of this size can be planned from the start.

Which homes this size is designed for

The RE2H80T10-1NCTT targets households whose hot water use is high and concentrated in time: a family of five, for example, or an intergenerational home where two kitchens and several bathrooms draw on the same tank. It also appeals to homeowners who have installed a large tub or a multi-jet shower and run short of hot water in the evening. For a couple or a small family, a more compact size will often make more sense; we will tell you so frankly during the assessment.

Why tank size matters with a heat pump

The compressor of a heat pump water heater heats water slowly, but with very little electricity. According to Bradford White, this model recovers 6 US gallons per hour with the compressor alone, and 24 US gallons per hour when the compressor and an element work together. In practical terms, the larger the reserve, the less the unit needs its elements during peaks. With 80 US gallons of hot water in reserve, morning showers draw on water that is already hot, and the heat pump rebuilds the reserve during the day and overnight. This is what lets a large family enjoy a heat pump water heater without spending its time in electric mode.

Manufacturer specifications

  • Capacity: 80 US gallons, 67 imperial gallons, 303 L.
  • Uniform Energy Factor (UEF): 3.59, based on the AHRI directory.
  • Recovery, compressor only: 6 US gal/h or 5 imperial gal/h at a 90 °F rise; 23 L/h at a 50 °C rise.
  • Recovery, compressor and element: 24 US gal/h or 20 imperial gal/h; 91 L/h.
  • Data measured in standard hybrid mode, at 19.7 °C (67.5 °F) ambient and 50% relative humidity.
  • Power supply: single-phase 240 V/208 V, interlocked (non-simultaneous) elements.
  • Screw-in backup elements: 4,000 W at 240 V; upper element of 3,000 W at 208 V.
  • Water connections: 3/4 in. (19 mm) NPT with factory-installed dielectric fittings.
  • Height: 70 13/16 in. (1,799 mm); diameter: 25 in. (635 mm).
  • Weight: 259 lb (117 kg).

The principle in a few lines

On top of the tank, a fan draws in room air and passes it over an evaporator. The refrigerant picks up the heat from the air, the compressor raises its temperature and a condenser transfers it to the water. A large part of the energy thus comes from the room air rather than from the power grid. The discharged air is cooler and drier, and two electric elements take over when demand requires it.

Five modes at the pace of a large family

Heat pump mode, which uses only the compressor, works very well with a tank this size when the household routine is steady. Standard hybrid mode remains the most versatile choice: the heat pump does most of the work and an element steps in as needed. During busier weeks, such as the holidays or a visit from relatives, hybrid plus mode relies more on the elements to keep the reserve full. Electric mode serves as a backup, and vacation mode slows the unit down while you are away. At commissioning, we set the mode according to your family's actual schedule.

Planning the location of a tall, heavy unit

At 70 13/16 in. tall and 259 lb, this water heater needs a little more planning than a standard replacement. We measure the headroom under the joists, the width of the stairs and doorways, and the strength of the floor at the intended spot. The manufacturer's location requirements, whether the room's air volume, the clearances or the drainage of condensate water, are confirmed on site. In new construction, it is simple to reserve the space and the drain at the planning stage; in an existing house, an unfinished basement or the mechanical room is usually the best choice.

Because the discharged air is cooler and drier, the unit cools and dries the room in summer. In winter, in a heated room, part of the captured heat comes from the home's heating system, a point we take into account in our advice.

Materials and compliance

The tank receives Bradford White's Vitraglas with Microban lining and a protective anode rod. The low-restriction brass drain valve allows quick flushing, and the factory-installed dielectric fittings on the 3/4 in. connections limit galvanic corrosion. The manufacturer states that the model is ENERGY STAR certified, UL listed, C.E.C. listed and meets NAECA requirements.

Power supply

The RE2H80T10-1NCTT runs on a 240 V/208 V single-phase supply, with factory wiring that keeps the two elements from heating at the same time. In a large, well-equipped home, the electrical panel must keep the necessary capacity; we check the existing circuit and the panel load, then confirm the breaker size according to the nameplate. Electrical work is done under our RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).

Manufacturer's warranty

Bradford White covers this "10" suffix model with a 10-year limited warranty on the tank and 10 years on parts. The detailed terms come with your quote.

AirGreen installs your 80 US gallon heat pump water heater from start to finish

A family-owned heating and cooling company established in Montreal, AirGreen has been active for more than fifteen years. After a free in-home estimate, you receive a written quote that sets out every step. Installation of the RE2H80T10-1NCTT includes:

  • checking the location, access, headroom and the drain for condensate water;
  • draining and removing the old tank, or preparing the space in new construction;
  • connecting the cold and hot water lines in 3/4 in. NPT;
  • installing the relief valve and its discharge line;
  • the electrical connection and a check of the panel;
  • commissioning, and setting the temperature and mode to your family's schedule;
  • maintenance advice: clear air intake, partial flushing, anode inspection.

Everywhere in Greater Montreal

We serve Montreal, Laval, Longueuil, Saint-Bruno, Varennes, Mirabel, Repentigny, Mascouche and the whole South Shore and North Shore. If you wish to spread out the investment, our financing option is presented with the quote.

Book your free estimate for the Bradford White RE2H80T10-1NCTT. A few photos of your current tank, the stairs and the intended location help us prepare an efficient visit.