BRADFORD WHITE RE2H65T10-1NCTT Heat Pump Water Heater (65 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: RE2H65T10-1NCTT
246 L65 US gal of storage
299 Lof hot water in the first hour
3.64UEF: 3.64 times more hot water than electricity
Talk to an expert · 514 316-2973
10-year tank warranty, 10-year parts3/4 in NPT connections240 V
01 · Running cost

What it will cost you each year

Pick your household. The math follows your hot water use, at the current Hydro-Québec rate.

$128

per year in heat pump mode, for 186 L of hot water a day

Standard 47 gal electric tank$524
This model, heat pump mode$128

What stays in your pocket over 10 years

Standard tankThis modelGap

The mode changes the bill

How we calculate. Mains water at 7 °C heated to 60 °C (Québec.ca), 75 L per person per day (Natural Resources Canada) or 186 L for the average Québec household. This model: energy ÷ UEF of 3.64. Standard tank: the same energy plus 59 W of standby loss (Bradford White RE250S6). Price: 11.142 ¢/kWh, Rate D second tier in force since April 1, 2026, before tax. UEF is a lab rating: in a cold basement in winter the elements do more of the work, and part of the heat comes from the house heating. Indicative estimate.

02 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 299 L

Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

03 · Why this model

What sets the Bradford White AeroTherm RE2H65T10 apart

3.64

Uniform Energy Factor

Bradford White's Canadian spec sheet lists a UEF of 3.64 for the RE2H65T10, based on the AHRI directory.

79 gal

First-hour rating

The manufacturer lists a first-hour rating of 79 US gallons (299 L).

2–49 °C

Ambient air range

The heat pump runs in ambient air from 2 to 49 °C (35 to 120 °F); outside that range the unit switches to electric mode.

700 cu ft

Minimum room volume

The installation manual requires a room of at least 700 cu ft (19.8 m³), otherwise louvers or a ducting kit are needed.

3.64

Best UEF in the series

At 3.64, the 65-gallon model has the highest UEF of the three RE2H units (3.44 for the 50, 3.59 for the 80).

04 · How it works

The same cycle as a wall heat pump, applied to water

1. Room airfan3. Exhaust aircooler, drierHot watertop outletCold waterenters lowcompressor2. Condensergives off heatbackup element
  1. The fan moves room air over the evaporator, where the refrigerant picks up its heat.
  2. The compressor concentrates that heat and gives it to the water in the tank.
  3. When demand climbs or the room leaves the 2.0 to 49.0 °C range, the electric element takes over.
05 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 63.75 in tall (1619 mm), 25 in across (635 mm), about 236 lb shipping weight. The clearances the manufacturer requires are checked on site.

06 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

07 · Installation

What the spot needs, and who does what

240 V circuit4,000 W elements. A dedicated circuit, sized by our electrician.
3/4 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
Condensate drainThe heat pump makes water: you need a floor drain or a pump nearby.
Air around itIt draws its heat from the room air: the volume and clearances the manufacturer requires are checked at the visit.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up and mode setting.

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

08 · Maintenance

A few habits that make it last

  1. Start-up dayMode choice and temperature, with you.
  2. At all timesKeep the air inlet and outlet clear and clean the air filter as the manual says.
  3. Every yearPartial drain to flush sediment, and a test of the relief valve.
  4. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
09 · Spec sheet

Every figure, with its source

Capacity and performance
Model
RE2H65T10-1NCTT
Capacity
65 US gal · 246 L
First-hour rating
79 US gal · 299 L
Uniform energy factor (UEF)
3.64
Recovery
6 US gal/h · 23 L/h
Heat pump air range
2.0 – 49.0 °C
Electrical
Supply
240 V, single phase
Element
4,000 W × 2
Element type
Screw-in
Dimensions and connections
Height
63.75 in · 1,619 mm
Diameter
25 in · 635 mm
Shipping weight (approx.)
236 lb · 107 kg
Water connections
3/4 in NPT
Build and warranty
Inner lining
Vitraglas with Microban
Drain valve
Brass
Limited warranty, tank
10 years
Limited warranty, parts
10 years

Manufacturer data. Detailed sources at the bottom of the page.

10 · Same family

The size below and above

11 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Does it work in a basement in winter?

Yes, as long as the room air stays between 2.0 and 49.0 °C. In a heated basement, part of the heat it captures comes from the house heating. Outside its range, it switches to the electric elements.

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 65 gallons enough for?

It delivers 299 L of hot water in the first hour. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).

12 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White AeroTherm Hybrid Electric HPWH spec sheet C1902-0725 CANADA · docs.bradfordwhite.com
  2. BPA HPWH Qualified Products List v80 · www.bpa.gov
  3. Hydro-Québec, rate grid, Rate D in force April 1, 2026 (7.065 ¢ and 11.142 ¢/kWh).
  4. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  5. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  6. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  7. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  8. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A 65 US gallon heat pump water heater that draws its heat from basement air

In many Greater Montreal homes, hot water still comes from a conventional electric tank that heats water with resistance elements alone. The Bradford White RE2H65T10-1NCTT heat pump water heater keeps the familiar shape of an upright tank, but hands most of the work to an integrated heat pump mounted on top of the unit. It holds 65 US gallons (54 imperial gallons, 246 L) and is aimed at homeowners who want to replace an ageing electric tank with a far more efficient unit without changing any of their habits. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

This size suits a single-family house where, for example, a family of three or four lives, with a main bathroom and a powder room. Its reserve gives the heat pump time to work between the morning and evening peaks, and that is exactly what allows a unit of this type to run on its compressor most of the time rather than on its elements.

How the heat pump heats the water

A heat pump water heater applies the principle of an ordinary heat pump to the tank. A fan moves room air across an evaporator, where the refrigerant picks up the heat contained in that air. The compressor then concentrates this heat and transfers it to the water in the tank. The air leaving the unit is therefore cooler and drier than when it went in. Because a good share of the energy comes from the surrounding air rather than from the meter, the unit delivers more heat to the water than it consumes in electricity.

Two backup electric elements, screw-in type, complete the heat pump. They take over when demand exceeds what the compressor can supply, or when you select a mode that calls on them. The factory wiring is interlocked: the two elements never heat at the same time (non-simultaneous, single-phase operation).

Manufacturer data for the RE2H65T10-1NCTT

The following values come from Bradford White's technical documentation for this model.

  • Capacity: 65 US gallons, or 54 imperial gallons or 246 L.
  • Uniform Energy Factor (UEF): 3.64, based on the AHRI directory.
  • Recovery, compressor only: 6 US gal/h (5 imperial gal/h) at a 90 °F rise, or 23 L/h at a 50 °C rise.
  • Recovery, compressor and element: 24 US gal/h (20 imperial gal/h), or 91 L/h.
  • Test conditions for these figures: standard hybrid mode, ambient air at 19.7 °C (67.5 °F) and 50% relative humidity.
  • Backup elements: 4,000 W at 240 V; at 208 V, the upper element is 3,000 W.
  • Water connections: 3/4 in. (19 mm) NPT, dielectric fittings installed at the factory.
  • Dimensions: height of 63 3/4 in. (1,619 mm), diameter of 25 in. (635 mm).
  • Weight: 236 lb (107 kg).

Five modes to follow the season and the demand

The control panel offers five operating modes. Heat pump mode uses the compressor only: it is the most frugal setting, well suited when demand is steady. Standard hybrid mode gives priority to the heat pump and calls on the elements only when needed; it is also the mode in which Bradford White establishes its recovery data. Hybrid plus mode relies more on the elements to rebuild the reserve faster, for example when the house has guests for a few days. Electric mode runs on the elements only, which serves as a backup solution. Finally, vacation mode reduces the unit's activity during an extended absence.

Where to put a heat pump water heater in a Quebec home

Because it draws its heat from the air, this unit needs enough air volume around it. In Quebec, the basement, the mechanical room or a large laundry room are the most common locations. The manufacturer's location requirements, namely the room volume, the clearances around the unit and the drainage of condensate water, are checked during our visit, before the project is confirmed. At 63 3/4 in. tall and 236 lb, the path down the stairs and the space under the joists are also part of the assessment.

The air discharged by the unit is cooler and drier. In summer, it cools and dries the basement, an effect many homeowners in the region appreciate. In winter, if the room is heated, part of the captured heat comes from the home's heating system. We take this into account in our recommendations rather than relying on the published energy factor alone.

Choosing the right capacity

A heat pump heats water more slowly than an electric element: with the compressor alone, recovery is 6 US gallons per hour. That is why tank size matters more than with a conventional water heater. The 65 US gallon reserve of this model covers a typical day for a mid-sized family, after which the heat pump quietly rebuilds it during off-peak hours. If several showers follow one another without a break, or if the house has a large soaker tub, we also compare it with the larger-capacity version of the same line before making a recommendation.

Construction and durability

The tank is protected by Bradford White's Vitraglas with Microban lining and by a protective anode rod, which wears over time in place of the steel. The 3/4 in. NPT water connections receive dielectric fittings at the factory, which limits corrosion between dissimilar metals. The low-restriction brass drain valve makes maintenance flushing easier, and the backup elements can be replaced without touching the tank since they are screw-in.

According to the manufacturer's documentation, the model is ENERGY STAR certified, UL listed, C.E.C. listed and meets NAECA requirements.

Electrical requirements

The unit is factory-wired for a 240 V/208 V single-phase supply, with interlocked elements. At 240 V, each backup element is 4,000 W. The existing tank circuit can often be reused, but we always check it: the breaker and conductor sizes are confirmed during the assessment, based on the unit's nameplate and the Code. Electrical connections are made under our RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work.

Manufacturer's warranty

This model carries the "10" suffix: Bradford White covers it with a 10-year limited warranty on the tank and 10 years on parts. The full warranty terms are provided with your quote.

Installation of the Bradford White RE2H65T10-1NCTT by AirGreen in Greater Montreal

AirGreen is a family-owned heating and cooling company established in Montreal and active for more than fifteen years. Every project begins with a free on-site estimate, followed by a written quote. For this heat pump water heater, our work includes:

  • assessing the location: air volume, clearances, headroom, access and a drain for condensate;
  • checking the electrical circuit and upgrading it if needed;
  • draining, disconnecting and removing the old tank;
  • connecting the cold and hot water lines in 3/4 in., with the relief valve and its discharge line;
  • the electrical connection and the condensate drain line;
  • commissioning, selecting the mode and setting the temperature;
  • maintenance advice tailored to how you use hot water.

Maintenance that keeps the heat pump efficient

A heat pump water heater needs little maintenance, but a few steps matter. The air intake and the evaporator must stay clear and clean so the heat pump gets enough air. A partial flush through the brass drain valve removes sediment, and periodic inspection of the anode protects the tank. We recommend one maintenance visit per year, especially in areas where the water is harder.

Service area

We install this model in Montreal, Laval and Longueuil, as well as in Brossard, Boucherville, Saint-Lambert, Terrebonne, Blainville and throughout the South Shore and the North Shore. Payments can be spread out through our financing program, presented with the quote.

Request your free estimate for the Bradford White RE2H65T10-1NCTT. Send us a few photos of your current tank and its location: we will schedule the visit and give you a clear written quote.