Uniform Energy Factor
Bradford White's Canadian spec sheet lists a UEF of 3.64 for the RE2H65T10, based on the AHRI directory.
Pick your household. The math follows your hot water use, at the current Hydro-Québec rate.
per year in heat pump mode, for 186 L of hot water a day
How we calculate. Mains water at 7 °C heated to 60 °C (Québec.ca), 75 L per person per day (Natural Resources Canada) or 186 L for the average Québec household. This model: energy ÷ UEF of 3.64. Standard tank: the same energy plus 59 W of standby loss (Bradford White RE250S6). Price: 11.142 ¢/kWh, Rate D second tier in force since April 1, 2026, before tax. UEF is a lab rating: in a cold basement in winter the elements do more of the work, and part of the heat comes from the house heating. Indicative estimate.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Bradford White's Canadian spec sheet lists a UEF of 3.64 for the RE2H65T10, based on the AHRI directory.
The manufacturer lists a first-hour rating of 79 US gallons (299 L).
The heat pump runs in ambient air from 2 to 49 °C (35 to 120 °F); outside that range the unit switches to electric mode.
The installation manual requires a room of at least 700 cu ft (19.8 m³), otherwise louvers or a ducting kit are needed.
At 3.64, the 65-gallon model has the highest UEF of the three RE2H units (3.44 for the 50, 3.59 for the 80).
It travels upright. Measure the ceiling at the spot and the narrowest door on the way.
Unit: 63.75 in tall (1619 mm), 25 in across (635 mm), about 236 lb shipping weight. The clearances the manufacturer requires are checked on site.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up and mode setting.
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes, as long as the room air stays between 2.0 and 49.0 °C. In a heated basement, part of the heat it captures comes from the house heating. Outside its range, it switches to the electric elements.
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 299 L of hot water in the first hour. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
In many Greater Montreal homes, hot water still comes from a conventional electric tank that heats water with resistance elements alone. The Bradford White RE2H65T10-1NCTT heat pump water heater keeps the familiar shape of an upright tank, but hands most of the work to an integrated heat pump mounted on top of the unit. It holds 65 US gallons (54 imperial gallons, 246 L) and is aimed at homeowners who want to replace an ageing electric tank with a far more efficient unit without changing any of their habits. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
This size suits a single-family house where, for example, a family of three or four lives, with a main bathroom and a powder room. Its reserve gives the heat pump time to work between the morning and evening peaks, and that is exactly what allows a unit of this type to run on its compressor most of the time rather than on its elements.
A heat pump water heater applies the principle of an ordinary heat pump to the tank. A fan moves room air across an evaporator, where the refrigerant picks up the heat contained in that air. The compressor then concentrates this heat and transfers it to the water in the tank. The air leaving the unit is therefore cooler and drier than when it went in. Because a good share of the energy comes from the surrounding air rather than from the meter, the unit delivers more heat to the water than it consumes in electricity.
Two backup electric elements, screw-in type, complete the heat pump. They take over when demand exceeds what the compressor can supply, or when you select a mode that calls on them. The factory wiring is interlocked: the two elements never heat at the same time (non-simultaneous, single-phase operation).
The following values come from Bradford White's technical documentation for this model.
The control panel offers five operating modes. Heat pump mode uses the compressor only: it is the most frugal setting, well suited when demand is steady. Standard hybrid mode gives priority to the heat pump and calls on the elements only when needed; it is also the mode in which Bradford White establishes its recovery data. Hybrid plus mode relies more on the elements to rebuild the reserve faster, for example when the house has guests for a few days. Electric mode runs on the elements only, which serves as a backup solution. Finally, vacation mode reduces the unit's activity during an extended absence.
Because it draws its heat from the air, this unit needs enough air volume around it. In Quebec, the basement, the mechanical room or a large laundry room are the most common locations. The manufacturer's location requirements, namely the room volume, the clearances around the unit and the drainage of condensate water, are checked during our visit, before the project is confirmed. At 63 3/4 in. tall and 236 lb, the path down the stairs and the space under the joists are also part of the assessment.
The air discharged by the unit is cooler and drier. In summer, it cools and dries the basement, an effect many homeowners in the region appreciate. In winter, if the room is heated, part of the captured heat comes from the home's heating system. We take this into account in our recommendations rather than relying on the published energy factor alone.
A heat pump heats water more slowly than an electric element: with the compressor alone, recovery is 6 US gallons per hour. That is why tank size matters more than with a conventional water heater. The 65 US gallon reserve of this model covers a typical day for a mid-sized family, after which the heat pump quietly rebuilds it during off-peak hours. If several showers follow one another without a break, or if the house has a large soaker tub, we also compare it with the larger-capacity version of the same line before making a recommendation.
The tank is protected by Bradford White's Vitraglas with Microban lining and by a protective anode rod, which wears over time in place of the steel. The 3/4 in. NPT water connections receive dielectric fittings at the factory, which limits corrosion between dissimilar metals. The low-restriction brass drain valve makes maintenance flushing easier, and the backup elements can be replaced without touching the tank since they are screw-in.
According to the manufacturer's documentation, the model is ENERGY STAR certified, UL listed, C.E.C. listed and meets NAECA requirements.
The unit is factory-wired for a 240 V/208 V single-phase supply, with interlocked elements. At 240 V, each backup element is 4,000 W. The existing tank circuit can often be reused, but we always check it: the breaker and conductor sizes are confirmed during the assessment, based on the unit's nameplate and the Code. Electrical connections are made under our RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work.
This model carries the "10" suffix: Bradford White covers it with a 10-year limited warranty on the tank and 10 years on parts. The full warranty terms are provided with your quote.
AirGreen is a family-owned heating and cooling company established in Montreal and active for more than fifteen years. Every project begins with a free on-site estimate, followed by a written quote. For this heat pump water heater, our work includes:
A heat pump water heater needs little maintenance, but a few steps matter. The air intake and the evaporator must stay clear and clean so the heat pump gets enough air. A partial flush through the brass drain valve removes sediment, and periodic inspection of the anode protects the tank. We recommend one maintenance visit per year, especially in areas where the water is harder.
We install this model in Montreal, Laval and Longueuil, as well as in Brossard, Boucherville, Saint-Lambert, Terrebonne, Blainville and throughout the South Shore and the North Shore. Payments can be spread out through our financing program, presented with the quote.
Request your free estimate for the Bradford White RE2H65T10-1NCTT. Send us a few photos of your current tank and its location: we will schedule the visit and give you a clear written quote.