YORK YC3 LX Central Air Conditioner | 3 Tons - 36000 BTU - R454B
The 3-ton York YC3 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.
Model numberYC336E2S11
514 316-2973 · sales@airgreen.ca
Quick facts
3 tons, the size that suits many Greater Montreal homes
The YC336E2S11 is the 3-ton (36,000 BTU/h) condensing unit of the York YC3 (LX) series, between the 2.5-ton and 3.5-ton sizes of the same series. It runs on R-454B, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.
The YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.
Which homes does it suit?
This size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.
The numbers for this size
For efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 74 dBA. It needs a 208/230 V single-phase circuit with a 18.2 A minimum circuit ampacity and a 30 A maximum time-delay fuse or breaker.
The unit ships with a factory charge of 2.88 lb (1.30 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 36 1/4 in high, with an operating weight of 140 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).
Running on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.
It cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.
To compare, still at 3 tons: York YC4 LX, York YC6 LX, York YC2E LX.
Installation by AirGreen
A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.
- Free on-site estimate and size validation;
- Written quote that specifies the matched indoor section and the electrical circuit;
- Setting the outdoor unit on a stable base and installing the indoor section;
- Refrigerant piping with a 3/4 in vapor valve, evacuation and charge adjustment;
- Electrical connection, commissioning and airflow check at the grilles.
The manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.
Get a quote
Ask for a free estimate: we confirm whether 3 tons is the right size, check the panel and the ducts, then give you a written quote. Financing is available.
The outdoor half of a 3-ton central air system
The YC336E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.
- Typical Greater Montreal bungalows and cottages with ductwork
- Adding air conditioning to an existing electric furnace
- Replacing a worn-out central air conditioner of the same size
- Outdoor unit placed away from a deck or a bedroom
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
- The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
- 208/230 V single-phase, 60 Hz circuit: 18.2 A minimum ampacity, 30 A maximum time-delay fuse or breaker.
- Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
- R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
Explore the range
Central air conditionersSee allSame brand
YORKSee all
Frequently asked questions
How do I know 3 tons is the right size?
We assess insulation, windows and duct capacity during the free estimate, then recommend the YC3 size that fits.
Does this air conditioner heat the house?
No. The YC336E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.
What indoor equipment does it work with?
A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 18.2 A minimum ampacity and a 30 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.
What warranty does the manufacturer offer?
According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.
A 3-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.