YORK YC3 LX Central Air Conditioner | 5 Tons - 60000 BTU - R454B

In stock

The 5-ton York YC3 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.

Model numberYC360E2S11

5 tons60,000 BTU/h nominal size
77 dBAsound power
R-454BCooling only208/230 V · single phase50 A max. breaker
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberYC360E2S11
ManufacturerYork
SeriesYC3 LX
Size5 tons (60,000 BTU/h)
RefrigerantR-454B
Minimum circuit ampacity30.9 A

A 5-ton York, when the house truly calls for it

At 60,000 BTU/h, the YC360E2S11 is the 5-ton size of the York YC3 (LX) series, the largest of the 7 sizes we offer in this series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.

The YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.

The right size for your home

It is kept for houses where 4 tons is no longer enough, for example a large multi-storey house with a lot of glazing or a major extension. At this size, the ducts, the furnace and the electrical panel all have to keep up; we check each of them during the estimate.

Technical data worth knowing

For efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 77 dBA. Electrical: 208/230 V single-phase circuit, 30.9 A minimum ampacity, 50 A maximum time-delay fuse or breaker.

The unit ships with a factory charge of 3.62 lb (1.64 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1/4 in at the base and 36 1/4 in high, with an operating weight of 230 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).

R-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.

Note: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.

To compare, still at 5 tons: York YC4 LX, York YC6 LX, York YCE LX.

What our installation includes

Our technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.

  1. Free visit: we measure and check the panel and the ducts;
  2. Written quote, with the planned indoor section and electrical circuit;
  3. Installing the condensing unit on a level base, and the indoor section;
  4. Connecting the piping with a 7/8 in vapor valve, evacuation and charge adjusted to the actual length;
  5. Electrical hookup, full test run and a walk-through of how it works.

The manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Let's talk about your home

Send us a free estimate request for the YC360E2S11: we validate the size on site and give you a written price, installation included. Financing is available.

01 · What it is for

The outdoor half of a 5-ton central air system

The YC360E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.

  • Very large houses cooled through a single duct system
  • Replacing a central air conditioner of the same size
  • Multi-storey houses with a large-capacity electric furnace
  • Outdoor unit installed away from the house
R-454B refrigerantThe new-generation refrigerant required for new air conditioners, with a lower global warming potential than R-410A.
30.9 A circuitPublished minimum circuit ampacity, with a 50 A maximum time-delay fuse or breaker.
Up to 80 ft of pipingMaximum equivalent length allowed by the manufacturer, so the unit can go where it bothers least.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
SeriesYC3 (LX)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
CompressorScroll, single stage
Sound power77 dBA
Power supply208/230 V, single phase, 60 Hz (187 to 252 V operating)
Minimum circuit ampacity30.9 A
Max. time-delay fuse or breaker50 A
Compressor (RLA / LRA)23.7 A / 157.0 A
Fan motor (FLA)1.30 A
Liquid valve3/8 in
Vapor valve7/8 in
Rated vapor line1 1/8 in
Factory charge3.62 lb (1.64 kg) of R-454B for 15 ft of piping
Piping lengthUp to 80 ft (24.4 m) equivalent
Low-ambient cooling55°F (12.8°C) without accessories; down to 20°F (-7°C) with the approved low-ambient kits
Dimensions (W x D x H)38 x 34 1/4 x 36 1/4 in
Operating weight230 lb (104.3 kg)
CabinetG90-equivalent steel, powder-coat paint rated for at least 500 h of salt spray (ASTM B117); top discharge
Model numberYC360E2S11
03 · Before installing

What to know before installing

  • Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
  • The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
  • 208/230 V single-phase, 60 Hz circuit: 30.9 A minimum ampacity, 50 A maximum time-delay fuse or breaker.
  • Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
  • R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
04 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
YORK
See all
05 · Questions

Frequently asked questions

Does my house really need 5 tons?

That is the first thing we check. An oversized unit cools quickly but dehumidifies poorly. We assess insulation, windows and ductwork during the free estimate, then recommend the YC3 size that fits.

Does this air conditioner heat the house?

No. The YC360E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.

What indoor equipment does it work with?

A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 30.9 A minimum ampacity and a 50 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.

What warranty does the manufacturer offer?

According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.