YORK YC6 LX Central Air Conditioner | 5 Tons - 60000 BTU - R454B
The 5-ton York YC6 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.
Model numberYC660E2S11
514 316-2973 · sales@airgreen.ca
Quick facts
A 5-ton York, when the house truly calls for it
The YC660E2S11 is the 5-ton (60,000 BTU/h) condensing unit of the York YC6 (LX) series, the largest of the 5 sizes we offer in this series. It runs on R-454B, with a two-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.
The YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.
Who it is for
It is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. Before talking about 5 tons, we check that it is the right choice: in some very large homes, two smaller systems, one per floor, give better comfort.
The numbers for this size
For efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 75 dBA. Electrical: 208/230 V single-phase circuit, 31.6 A minimum ampacity, 50 A maximum time-delay fuse or breaker.
The unit ships with a factory charge of 5.5 lb (2.49 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1/4 in at the base and 42 3/4 in high, with an operating weight of 255 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).
R-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.
It cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.
Same size, other series: York YC4 LX, York YC3 LX, York YC2D LX.
What our installation includes
A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.
- Free on-site estimate and size validation;
- Written quote that specifies the matched indoor section and the electrical circuit;
- Setting the outdoor unit on a stable base and installing the indoor section;
- Refrigerant piping with a 7/8 in vapor valve, evacuation and charge adjustment;
- Electrical connection, commissioning and airflow check at the grilles.
We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
The next step
Send us a free estimate request for the YC660E2S11: we validate the size on site and give you a written price, installation included. Financing is available.
The outdoor half of a 5-ton central air system
The YC660E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.
- Very large houses cooled through a single duct system
- Replacing a central air conditioner of the same size
- Multi-storey houses with a large-capacity electric furnace
- Outdoor unit installed away from the house
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
- The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
- 208/230 V single-phase, 60 Hz circuit: 31.6 A minimum ampacity, 50 A maximum time-delay fuse or breaker.
- Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
- R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
Explore the range
Central air conditionersSee allSame brand
YORKSee all
Frequently asked questions
Does my house really need 5 tons?
That is the first thing we check. An oversized unit cools quickly but dehumidifies poorly. We assess insulation, windows and ductwork during the free estimate, then recommend the YC6 size that fits.
Does this air conditioner heat the house?
No. The YC660E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.
What indoor equipment does it work with?
A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 31.6 A minimum ampacity and a 50 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.
What warranty does the manufacturer offer?
According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.
A 5-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.