YORK YC6 LX Central Air Conditioner | 2 Tons - 24000 BTU - R454B
The 2-ton York YC6 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.
Model numberYC624E2S11
514 316-2973 · sales@airgreen.ca
Quick facts
The 2-ton YC6: cooling a small home that already has ductwork
The YC624E2S11 is the 2-ton (24,000 BTU/h) condensing unit of the York YC6 (LX) series, between the 1.5-ton and 3-ton sizes of the same series. It runs on R-454B, with a two-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.
The YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.
Who it is for
It is the typical size for a condo or a townhouse where the electrical panel is already well filled and outdoor space is tight. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 20 A maximum breaker is enough, which often avoids major panel work.
Technical data worth knowing
For efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. Electrical: 208/230 V single-phase circuit, 13.7 A minimum ampacity, 20 A maximum time-delay fuse or breaker.
The unit ships with a factory charge of 3 lb (1.36 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1/4 x 29 1/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).
R-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.
Note: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.
Other York series offered at 2 tons: York YC4 LX, York YC3 LX, York YXT Affinity.
Installation by AirGreen
Our technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.
- Free on-site estimate and size validation;
- Written quote that specifies the matched indoor section and the electrical circuit;
- Setting the outdoor unit on a stable base and installing the indoor section;
- Refrigerant piping with a 3/4 in vapor valve, evacuation and charge adjustment;
- Electrical connection, commissioning and airflow check at the grilles.
We install throughout Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.
Get a quote
Torn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. Financing is available.
The outdoor half of a 2-ton central air system
The YC624E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.
- Adding central air to a house heated by an electric furnace
- Modest bungalows, townhouses and condos that already have ductwork
- Replacing a condensing unit of the same size on existing ductwork
- Electrical panels with little room left for a new circuit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
- The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
- 208/230 V single-phase, 60 Hz circuit: 13.7 A minimum ampacity, 20 A maximum time-delay fuse or breaker.
- Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
- R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
Explore the range
Central air conditionersSee allSame brand
YORKSee all
Frequently asked questions
Is this size enough for my house?
For a modest bungalow, a townhouse or a condo, it often is. We confirm it during the free estimate by assessing insulation, windows and ductwork.
Does this air conditioner heat the house?
No. The YC624E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.
What indoor equipment does it work with?
A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 13.7 A minimum ampacity and a 20 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.
What warranty does the manufacturer offer?
According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.
A 2-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.