YORK YC6 LX Central Air Conditioner | 1.5 Tons - 18000 BTU - R454B
The 1.5-ton York YC6 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.
Model numberYC618E2S11
514 316-2973 · sales@airgreen.ca
Quick facts
1.5 tons of central air for a condo, a townhouse or a small bungalow
At 18,000 BTU/h, the YC618E2S11 is the 1.5-ton size of the York YC6 (LX) series, the smallest of the 5 sizes we offer in this series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage rotary compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.
The YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.
Which homes does it suit?
It is the typical size for a condo or a townhouse where the electrical panel is already well filled and outdoor space is tight. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 15 A maximum breaker is enough, which often avoids major panel work.
What the manufacturer's spec sheet says
For efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. At 71 dBA of sound power, it is the quietest size in the series. It needs a 208/230 V single-phase circuit with a 9.3 A minimum circuit ampacity and a 15 A maximum time-delay fuse or breaker.
The unit ships with a factory charge of 3.62 lb (1.64 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1/4 x 29 1/4 in at the base and 36 1/4 in high, with an operating weight of 165 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).
R-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.
Note: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.
Same size, other series: York YC3 LX, York YC2E LX, York YC2D LX.
Installation by AirGreen
A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.
- Free visit: we measure and check the panel and the ducts;
- Written quote, with the planned indoor section and electrical circuit;
- Installing the condensing unit on a level base, and the indoor section;
- Connecting the piping with a 3/4 in vapor valve, evacuation and charge adjusted to the actual length;
- Electrical hookup, full test run and a walk-through of how it works.
We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Get a quote
Torn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. Financing is available.
The outdoor half of a 1.5-ton central air system
The YC618E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.
- Adding central air to a house heated by an electric furnace
- Modest bungalows, townhouses and condos that already have ductwork
- Replacing a condensing unit of the same size on existing ductwork
- Electrical panels with little room left for a new circuit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
- The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
- 208/230 V single-phase, 60 Hz circuit: 9.3 A minimum ampacity, 15 A maximum time-delay fuse or breaker.
- Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
- R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
Explore the range
Central air conditionersSee allSame brand
YORKSee all
Frequently asked questions
Is this size enough for my house?
For a modest bungalow, a townhouse or a condo, it often is. We confirm it during the free estimate by assessing insulation, windows and ductwork.
Does this air conditioner heat the house?
No. The YC618E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.
What indoor equipment does it work with?
A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 9.3 A minimum ampacity and a 15 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.
What warranty does the manufacturer offer?
According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.
A 1.5-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.