YORK YC6 LX Central Air Conditioner | 1.5 Tons - 18000 BTU - R454B

In stock

The 1.5-ton York YC6 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.

Model numberYC618E2S11

1.5 tons18,000 BTU/h nominal size
71 dBAsound power
R-454BCooling only208/230 V · single phase15 A max. breaker
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberYC618E2S11
ManufacturerYork
SeriesYC6 LX
Size1.5 tons (18,000 BTU/h)
RefrigerantR-454B
Minimum circuit ampacity9.3 A

1.5 tons of central air for a condo, a townhouse or a small bungalow

At 18,000 BTU/h, the YC618E2S11 is the 1.5-ton size of the York YC6 (LX) series, the smallest of the 5 sizes we offer in this series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage rotary compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.

The YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.

Which homes does it suit?

It is the typical size for a condo or a townhouse where the electrical panel is already well filled and outdoor space is tight. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 15 A maximum breaker is enough, which often avoids major panel work.

What the manufacturer's spec sheet says

For efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. At 71 dBA of sound power, it is the quietest size in the series. It needs a 208/230 V single-phase circuit with a 9.3 A minimum circuit ampacity and a 15 A maximum time-delay fuse or breaker.

The unit ships with a factory charge of 3.62 lb (1.64 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1/4 x 29 1/4 in at the base and 36 1/4 in high, with an operating weight of 165 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).

R-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.

Note: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.

Same size, other series: York YC3 LX, York YC2E LX, York YC2D LX.

Installation by AirGreen

A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.

  1. Free visit: we measure and check the panel and the ducts;
  2. Written quote, with the planned indoor section and electrical circuit;
  3. Installing the condensing unit on a level base, and the indoor section;
  4. Connecting the piping with a 3/4 in vapor valve, evacuation and charge adjusted to the actual length;
  5. Electrical hookup, full test run and a walk-through of how it works.

We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Get a quote

Torn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. Financing is available.

01 · What it is for

The outdoor half of a 1.5-ton central air system

The YC618E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.

  • Adding central air to a house heated by an electric furnace
  • Modest bungalows, townhouses and condos that already have ductwork
  • Replacing a condensing unit of the same size on existing ductwork
  • Electrical panels with little room left for a new circuit
R-454B refrigerantThe new-generation refrigerant required for new air conditioners, with a lower global warming potential than R-410A.
9.3 A circuitPublished minimum circuit ampacity, with a 15 A maximum time-delay fuse or breaker.
Up to 75 ft of pipingMaximum equivalent length allowed by the manufacturer, so the unit can go where it bothers least.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
SeriesYC6 (LX)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size1.5 tons (18,000 BTU/h)
RefrigerantR-454B
CompressorRotary, single stage
Sound power71 dBA
Power supply208/230 V, single phase, 60 Hz (187 to 252 V operating)
Minimum circuit ampacity9.3 A
Max. time-delay fuse or breaker15 A
Compressor (RLA / LRA)6.7 A / 33 A
Fan motor (FLA)2.0 A
Liquid valve3/8 in
Vapor valve3/4 in
Factory charge3.62 lb (1.64 kg) of R-454B for 15 ft of piping
Piping lengthUp to 75 ft (22.9 m) equivalent
Low-ambient cooling55°F (12.8°C) without accessories; down to 20°F (-7°C) with the approved low-ambient kits
Dimensions (W x D x H)29 1/4 x 29 1/4 x 36 1/4 in
Operating weight165 lb (74.8 kg)
CabinetG90-equivalent steel, powder-coat paint rated for at least 500 h of salt spray (ASTM B117); top discharge
Model numberYC618E2S11
03 · Before installing

What to know before installing

  • Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
  • The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
  • 208/230 V single-phase, 60 Hz circuit: 9.3 A minimum ampacity, 15 A maximum time-delay fuse or breaker.
  • Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
  • R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
04 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
YORK
See all
05 · Questions

Frequently asked questions

Is this size enough for my house?

For a modest bungalow, a townhouse or a condo, it often is. We confirm it during the free estimate by assessing insulation, windows and ductwork.

Does this air conditioner heat the house?

No. The YC618E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.

What indoor equipment does it work with?

A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 9.3 A minimum ampacity and a 15 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.

What warranty does the manufacturer offer?

According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.