YORK YC6 LX Central Air Conditioner | 4 Tons - 48000 BTU - R454B
The 4-ton York YC6 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.
Model numberYC648E2S11
514 316-2973 · sales@airgreen.ca
Quick facts
A 4-ton York for a large house on a single duct system
At 48,000 BTU/h, the YC648E2S11 is the 4-ton size of the York YC6 (LX) series, between the 3-ton and 5-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a two-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.
The YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.
Which homes does it suit?
This size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.
Technical data worth knowing
For efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 74 dBA. It needs a 208/230 V single-phase circuit with a 27.3 A minimum circuit ampacity and a 45 A maximum time-delay fuse or breaker.
The unit ships with a factory charge of 4.69 lb (2.13 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1/4 in at the base and 39 1/2 in high, with an operating weight of 250 lb, 15 lb more than the 3-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).
Running on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.
This condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.
To compare, still at 4 tons: York YC4 LX, York YC3 LX, York YXT Affinity.
Installation by AirGreen
AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.
- Free on-site estimate and size validation;
- Written quote that specifies the matched indoor section and the electrical circuit;
- Setting the outdoor unit on a stable base and installing the indoor section;
- Refrigerant piping with a 7/8 in vapor valve, evacuation and charge adjustment;
- Electrical connection, commissioning and airflow check at the grilles.
We install throughout Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.
The next step
Ask for a free estimate: we confirm whether 4 tons is the right size, check the panel and the ducts, then give you a written quote. Financing is available.
The outdoor half of a 4-ton central air system
The YC648E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.
- Large multi-storey houses cooled through a single duct system
- Open-plan and heavily glazed houses
- Replacing a central air conditioner of the same size
- Large-capacity electric furnace or fan coil
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
- The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
- 208/230 V single-phase, 60 Hz circuit: 27.3 A minimum ampacity, 45 A maximum time-delay fuse or breaker.
- Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
- R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
Explore the range
Central air conditionersSee allSame brand
YORKSee all
Frequently asked questions
Are my ducts big enough for 4 tons?
We always check this at this size. Undersized ducts make the air noisy at the grilles and reduce performance; we assess them during the free estimate.
Does this air conditioner heat the house?
No. The YC648E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.
What indoor equipment does it work with?
A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 27.3 A minimum ampacity and a 45 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.
What warranty does the manufacturer offer?
According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.
A 4-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.