YORK YC3 LX Central Air Conditioner | 2 Tons - 24000 BTU - R454B

In stock

The 2-ton York YC3 condensing unit: the outdoor half of an R-454B central air conditioner, matched with a coil or a fan coil.

Model numberYC324E2S11

2 tons24,000 BTU/h nominal size
74 dBAsound power
R-454BCooling only208/230 V · single phase20 A max. breaker
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberYC324E2S11
ManufacturerYork
SeriesYC3 LX
Size2 tons (24,000 BTU/h)
RefrigerantR-454B
Minimum circuit ampacity12.7 A

A small York size to add central air without overloading the panel

At 24,000 BTU/h, the YC324E2S11 is the 2-ton size of the York YC3 (LX) series, between the 1.5-ton and 2.5-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage rotary compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.

The YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.

The right size for your home

This size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 20 A maximum breaker is enough, which often avoids major panel work.

The numbers for this size

For efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 74 dBA. Electrical: 208/230 V single-phase circuit, 12.7 A minimum ampacity, 20 A maximum time-delay fuse or breaker.

The unit ships with a factory charge of 2.75 lb (1.25 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 33 1/4 in high, with an operating weight of 135 lb, 15 lb more than the 1.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).

Running on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.

This condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.

To compare, still at 2 tons: York YC6 LX, York YC4 LX, York YC2E LX.

How the installation goes

A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.

  1. Free visit: we measure and check the panel and the ducts;
  2. Written quote, with the planned indoor section and electrical circuit;
  3. Installing the condensing unit on a level base, and the indoor section;
  4. Connecting the piping with a 3/4 in vapor valve, evacuation and charge adjusted to the actual length;
  5. Electrical hookup, full test run and a walk-through of how it works.

The manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.

Let's talk about your home

Torn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. Financing is available.

01 · What it is for

The outdoor half of a 2-ton central air system

The YC324E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.

  • Adding central air to a house heated by an electric furnace
  • Modest bungalows, townhouses and condos that already have ductwork
  • Replacing a condensing unit of the same size on existing ductwork
  • Electrical panels with little room left for a new circuit
R-454B refrigerantThe new-generation refrigerant required for new air conditioners, with a lower global warming potential than R-410A.
12.7 A circuitPublished minimum circuit ampacity, with a 20 A maximum time-delay fuse or breaker.
Up to 80 ft of pipingMaximum equivalent length allowed by the manufacturer, so the unit can go where it bothers least.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
SeriesYC3 (LX)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
CompressorRotary, single stage
Sound power74 dBA
Power supply208/230 V, single phase, 60 Hz (187 to 252 V operating)
Minimum circuit ampacity12.7 A
Max. time-delay fuse or breaker20 A
Compressor (RLA / LRA)9.6 A / 53.0 A
Fan motor (FLA)0.70 A
Liquid valve3/8 in
Vapor valve3/4 in
Factory charge2.75 lb (1.25 kg) of R-454B for 15 ft of piping
Piping lengthUp to 80 ft (24.4 m) equivalent
Low-ambient cooling55°F (12.8°C) without accessories; down to 20°F (-7°C) with the approved low-ambient kits
Dimensions (W x D x H)24 x 24 x 33 1/4 in
Operating weight135 lb (61.2 kg)
CabinetG90-equivalent steel, powder-coat paint rated for at least 500 h of salt spray (ASTM B117); top discharge
Model numberYC324E2S11
03 · Before installing

What to know before installing

  • Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
  • The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
  • 208/230 V single-phase, 60 Hz circuit: 12.7 A minimum ampacity, 20 A maximum time-delay fuse or breaker.
  • Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
  • R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
04 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
YORK
See all
05 · Questions

Frequently asked questions

Is this size enough for my house?

For a modest bungalow, a townhouse or a condo, it often is. We confirm it during the free estimate by assessing insulation, windows and ductwork.

Does this air conditioner heat the house?

No. The YC324E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.

What indoor equipment does it work with?

A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 12.7 A minimum ampacity and a 20 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.

What warranty does the manufacturer offer?

According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.