Échangeur d'Air Broan ERV BLP130E80NS-PC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord
Is it the right size for your home?
It delivers 121 cfm net, enough to ventilate 1,400 to 2,300 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 121 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$26.35
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 49 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 27 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
5 in130 version: 5 in ports and 121 cfm at 0.4 in
The BLP130E80NS-PC has 5 in ports instead of the 4 in ports of the BLP120E units, and delivers 121 net cfm at 0.4 in versus 112 cfm. Like the BLP120E80NS-PC, it plugs in with a 6-ft cord.
DampersMagnetic backdraft dampers included
Magnetic backdraft dampers are supplied for the fresh-air and exhaust streams, while they are sold separately (VBACKDRAFT4) for the BLP120E units. A fresh-air damper is required when the ducts connect to a central forced-air system.
60%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 49 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005428Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.
−8 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 129 to 121 cfm. Most spec sheets show only the first number, precisely because it looks better.
27 WMeasured at the airflow it actually runs at
Its 80% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 27 W, or about 237 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years. We register the warranty in your name at commissioning.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat: $500 to install or replace an HRV or ERV
First condition met: HVI Section III certified, No. 2005428. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 129 cfm
- Net airflow at 0.4 in. w.g.
- 121 cfm
- SRE at 0 °C (49 cfm)
- 80%
- SRE at −25 °C (49 cfm)
- 60%
- ASE at 0 °C
- 83%
- Power draw
- 27 W
- Efficacy
- 1.8 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- Washable filters included; optional 1-in disposable MERV 13 fresh-air filter (V27000)
- Dimensions (L × D × H)
- 28.13 × 18.63 × 9.88 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005428
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005428). Annual consumption calculated at 27 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
La version 130 de l'EDGE : bouches de 5 po et volets inclus
Le Broan EDGE BLP130E80NS-PC partage le boîtier des BLP120E, mais deux choses changent. Ses bouches passent à 5 po, et il livre 121 pcm nets à 0,4 po au lieu de 112 pcm. Ses volets anti-retour magnétiques sont aussi fournis dans la boîte. Ce ventilateur récupérateur d'énergie (VRE) se branche avec un cordon de 6 pi.
Il s'adresse aux maisons dont le calcul de ventilation dépasse un peu ce que la version 120 fournit, et aux installations raccordées à une fournaise, où les volets sont exigés.
Ce qui le distingue
Des bouches de 5 po et plus de débit
Avec des bouches de 5 po, le BLP130E80NS-PC livre un débit net de 121 pcm à 0,4 po et de 129 pcm à 0,2 po. La plage annoncée commence à 30 pcm. Si vos conduits existants sont de 4 po, il faut en tenir compte : les raccords et les hottes doivent correspondre au diamètre de l'appareil.
Des volets anti-retour magnétiques fournis
Des volets anti-retour magnétiques sont inclus pour l'air frais et pour l'air vicié; ils sont vendus séparément (VBACKDRAFT4) pour les BLP120E. Ils empêchent l'air extérieur d'entrer quand l'appareil est à l'arrêt. Un volet sur l'air frais est requis si les conduits sont raccordés à un système central à air pulsé : avec ce modèle, il est déjà dans la boîte.
Efficacité, consommation et contrôle
HVI mesure une efficacité de récupération sensible de 80 % à 0 °C et de 60 % à −25 °C, au même débit d'essai de 49 pcm. C'est au-dessus du seuil de 54 % de la section 9.32 du Code de construction du Québec pour le Grand Montréal. Le noyau à contre-courant en polymère transfère aussi l'humidité et se lave.
L'appareil tire 27 W au débit d'essai, soit 1,8 pcm/W. En marche continue, cela correspond à environ 237 kWh par année, ou autour de 26 $.
Comme les autres EDGE, il utilise deux moteurs ECM à aimants permanents et la technologie VIRTUO, qui fait 120 lectures par minute pour garder le débit demandé et l'équilibre entre les deux flux. L'écran ACL règle le débit par pas de 1 pcm et affiche les watts en temps réel. Le même sélecteur intégré permet d'inverser la configuration des circulations d'air pour un plan en miroir.
Le dégivrage s'active de lui-même quand le noyau commence à geler, et aucun drain de condensat n'est requis. L'appareil est conforme aux exigences pour climat froid selon la fiche de Broan.
Installation
- Raccordement : latéral, bouches de 5 po; pose verticale possible.
- Drain : aucun.
- Dimensions : 28,13 × 18,63 × 9,88 po.
- Poids : 34 lb.
- Fixation : 4 supports inclus pour le mur, le sol, le dessous d'un plafond ou l'espace entre des poutrelles.
- Alimentation : cordon de 6 pi, prise de 120 V.
Si l'appareil est raccordé à un système à air pulsé, le guide demande, là où la température extérieure de calcul descend sous −20 °C, de synchroniser le VRE avec le fonctionnement du système central. Nous vérifions ce point pour chaque adresse.
Entretien
Les filtres lavables inclus se nettoient aux 3 mois, par des portes d'accès intégrées. Un filtre MERV 13 jetable de 1 po (V27000) peut être ajouté sur l'air frais. L'afficheur de défauts signale les filtres à nettoyer et les débits trop faibles.
Terminaisons extérieures
Broan indique que le BLP130E80NS-PC est compatible avec les terminaisons Tandem (VTYIK1 et V14695), qui regroupent l'entrée et la sortie d'air dans un seul passage de mur. Les conduits doivent alors être choisis pour correspondre au raccord de 5 po de ces terminaisons.
Garantie
Broan indique 5 ans sur le noyau et 5 ans sur les pièces.
Rénoclimat
Le BLP130E80NS-PC peut être admissible à l'aide Rénoclimat de 500 $ si l'appareil est homologué à la section III du répertoire HVI (c'est le cas du BLP130E80NS-PC, numéro HVI 2005428) et si la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux.
Installation par AirGreen dans le Grand Montréal
Le choix entre la version 120 et la version 130 se fait sur les chiffres. Nous calculons le besoin de chaque pièce selon la norme CSA F326, nous regardons le diamètre des conduits et la présence d'une fournaise, puis nous recommandons l'un ou l'autre. Après la pose, le débit calculé est programmé à l'écran et vérifié à l'alimentation comme à l'extraction.
Nous desservons Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud.
Pour une soumission gratuite, composez le 514 316-2973 ou écrivez à sales@airgreen.ca.