Broan-NuTone ERV V150E75NS Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 129 cfm net. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$14.64
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 64% at 67 cfm.
Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 15 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
19.13 inSide ports: only 19.13 in high
Its 5-in ports are on the sides, so the unit is just 19.13 in high, versus 21.5 in for the top-port V150E75NT. Ducts come in from the side, an advantage under low joists.
MembraneMembrane core: vacuum-only maintenance
The polypropylene core with its polymer membrane is not washable. At maintenance it is dusted with a vacuum and a soft brush, following the guide; the maker says never to soak it in water.
64%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 67 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005443Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−9 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 138 to 129 cfm. Most spec sheets show only the first number, precisely because it looks better.
15 WMeasured at the airflow it actually runs at
Its 82% at 0 °C is certified at 36 cfm, the continuous airflow of a typical home. At that setting it draws 15 W, or about 131 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 37 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 138 cfm
- Net airflow at 0.4 in. w.g.
- 129 cfm
- SRE at 0 °C (36 cfm)
- 82%
- SRE at −25 °C (67 cfm)
- 64%
- ASE at 0 °C
- 87%
- Power draw
- 15 W
- Efficacy
- 2.4 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851)
- Dimensions (L × D × H)
- 23.38 × 16.13 × 19.13 in
- Weight
- 37 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005443
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005443). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 15 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The V150E75NS is the low version of the 138 cfm ERV in the AI Series. Its 5-in. ports exit on the sides, which brings the unit down to 19.13 in. high, versus 21.5 in. for the top-port V150E75NT. The ducts come in from the side instead of dropping down onto the unit, an advantage under low joists. And since it is an ERV, there is no drain to connect.
The trade-off is in the width: 23.38 in. instead of 21 in., for the same 16.13 in. depth.
Same figures as the V150E75NT
Apart from the port layout and the shape of the cabinet, the two siblings are equal: 138 cfm at 0.2 in. and 129 cfm at 0.4 in., a sensible recovery efficiency of 82% at 36 cfm and 0 °C per HVI, then 64.0% at 66.5 cfm and −25 °C per NRCan’s ENERGY STAR list, where both models are listed. Same weight too, 37 lb.
A membrane core, cleaned dry
The V150E75NS has a polypropylene core with a polymer membrane, and that changes the maintenance. This core is not washable. At maintenance, it is dusted with a vacuum and a soft brush, following the maker’s guide, which says never to soak it in water. That care is no small detail, since the parts warranty assumes a maintained core.
ERV or HRV in the same format
The same low cabinet comes as an HRV: the V150H75NS delivers 150 cfm at 0.2 in., but it requires a drain. The V150E75NS, with its membrane core, does without one.
What to plan for
- Measurements: the clear height and the available width, since the unit is 19.13 in. high and 23.38 in. wide.
- Airflow: set at installation, room by room, following CSA F326.
- Power: 120 V.
- Filters: a washable MERV 8 is supplied; a disposable MERV 13 (V242851) is available as an option.
Specifications
- Type: ERV (energy recovery ventilator) with a membrane core, Broan-NuTone AI Series
- ENERGY STAR (Canada): Yes (on NRCan’s ENERGY STAR list under the Broan brand, list checked November 12, 2026)
- Net airflow: 138 cfm at 0.2 in.; 129 cfm at 0.4 in. of static pressure
- Sensible recovery efficiency: 82% at 36 cfm and 0 °C (HVI, Section III, No. 2005443); 64.0% at 66.5 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 23.38 × 16.13 × 19.13 in.
- Weight: 37 lb
- Ducts: 5 in.
- Connection: side (ports on the sides)
- Drain: not required
- Defrost: starts at −5 °C (thermistor next to the fresh-air port)
- Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851)
- HVI listing (Section III): No. 2005443
- Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 5 years on the core. Labour and shipping not covered. Residential use; original invoice required.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote, call us at 514 316-2973 or email us at sales@airgreen.ca.