Broan-NuTone ERV V150E75NT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: V150E75NT
129 cfm net64% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 129 cfm net. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
64%
At −25 °CCode: 55% minimum
82%
At 0 °CCertified at 36 cfm
Net airflowThe ducts cost it 9 cfm
0.2 in · test bench138 cfm
0.4 in · with ducts129 cfm

$14.64

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

15W
Running continuously
131kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 64% at 67 cfm.

Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 15 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

6 in6-in ducts advised above 130 cfm

The ports are 5 in, but for this model the maker recommends 6-in ducts whenever the required airflow exceeds 130 cfm, to avoid excessive static pressure. 5-to-6-in transitions fit on the ports.

TandemA single wall opening with the Tandem transition

Compatible with Tandem terminations (VTYIK1 and V14695), which replace the two exterior hoods. The maker allows them up to 160 cfm at 0.4 in w.g. (this model: 129 cfm); a 9.75 in joist opening is needed and some extra static pressure must be expected.

64%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 67 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005444Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−9 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 138 to 129 cfm. Most spec sheets show only the first number, precisely because it looks better.

15 WMeasured at the airflow it actually runs at

Its 82% at 0 °C is certified at 36 cfm, the continuous airflow of a typical home. At that setting it draws 15 W, or about 131 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in ducts, top connection. It weighs 37 lb, and it needs enough clearance to slide the core out once a year.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Top connectionTop ports
37 lbUnit weight
21 × 16.13 × 21.5 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
138 cfm
Net airflow at 0.4 in. w.g.
129 cfm
SRE at 0 °C (36 cfm)
82%
SRE at −25 °C (67 cfm)
64%
ASE at 0 °C
87%
Power draw
15 W
Efficacy
2.4 cfm/W
Type
ERV
Connection
Top ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851)
Dimensions (L × D × H)
21 × 16.13 × 21.5 in
Weight
37 lb
Power supply
120 V
HVI certification (Section III)
2005444
Warranty — core
5 years
Warranty — motors
5 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005444). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 15 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Same top-port cabinet, same 21-in. width, same sensible recovery efficiency of 82% at 36 cfm and 0 °C per HVI: on paper, the V150E75NT looks a lot like the V150H75NT HRV. The difference is inside the unit. The V150E75NT is an ERV, with a membrane core, and it needs no drain. The V150H75NT, on the other hand, must be connected to a drain.

In exchange, the ERV moves a little less air: 138 cfm at 0.2 in. and 129 cfm at 0.4 in., versus 150 and 140 cfm for the HRV. Both are on NRCan’s ENERGY STAR list, which gives 64.0% at 66.5 cfm and −25 °C for the V150E75NT and 63.3% at 63.6 cfm for the V150H75NT.

Duct size is decided up front

The ports are 5 in., but for this model the maker recommends 6-in. ducts whenever the required airflow exceeds 130 cfm, to avoid excessive static pressure. That required airflow is worked out room by room following CSA F326, when the duct layout is drawn. If it is above 130 cfm, 5-to-6-in. transitions go on the ports.

A single wall opening with Tandem

The V150E75NT accepts Tandem terminations (VTYIK1 and V14695), which replace the two exterior hoods with a single wall opening. The maker allows them up to 160 cfm at 0.4 in., and this model delivers 129 at that pressure. You do need 9.75 in. between the joists, though, and some extra static pressure in the system.

NT or NS

Its side-port sibling, the V150E75NS, has the same net airflow and the same efficiency figures. It is lower (19.13 in. versus 21.5 in.) but wider (23.38 in. versus 21 in.). When the ducts come in from above, the V150E75NT is the one we install.

On site

The unit runs on 120 V and weighs 37 lb. Defrost starts at −5 °C, read by a thermistor next to the fresh-air port. It comes with a washable MERV 8 filter, and a disposable MERV 13 filter (V242851) is available as an option. Airflow is then set at commissioning, room by room.

Specifications

  • Type: ERV (energy recovery ventilator) with a membrane core, Broan-NuTone AI Series
  • ENERGY STAR (Canada): Yes (on NRCan’s ENERGY STAR list under the Broan brand, list checked November 12, 2026)
  • Net airflow: 138 cfm at 0.2 in.; 129 cfm at 0.4 in. of static pressure
  • Sensible recovery efficiency: 82% at 36 cfm and 0 °C (HVI, Section III, No. 2005444); 64.0% at 66.5 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
  • Voltage: 120 V, 60 Hz
  • Dimensions (W × D × H): 21 × 16.13 × 21.5 in.
  • Weight: 37 lb
  • Ducts: 5-in. ports (6-in. ducts advised above 130 cfm)
  • Connection: top
  • Drain: not required
  • Defrost: starts at −5 °C (thermistor next to the fresh-air port)
  • Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851)
  • HVI listing (Section III): No. 2005444
  • Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 5 years on the core. Labour and shipping not covered. Residential use; original invoice required.

Sold and installed by AirGreen.

We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote, call us at 514 316-2973 or email us at sales@airgreen.ca.