Broan-NuTone ERV V210E75RT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 206 cfm net. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 206 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$27.33
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 67% at 83 cfm.
Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 28 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
24.81 inTop ports and a 24.81 in wide cabinet
All four ducts connect on top and run straight up to the joists. The cabinet is 24.81 in wide, versus 27.13 in for the side-port version (V210E75RS), which helps in a narrow room.
8 in8-in ducts advised above 200 cfm
This ERV reaches 210 cfm. Above 200 cfm with long runs or many elbows, the maker recommends 8-in rather than 6-in ducts, connected with 6-to-8-in transitions, to avoid excessive static pressure.
67%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005445Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−4 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 210 to 206 cfm. Most spec sheets show only the first number, precisely because it looks better.
28 WMeasured at the airflow it actually runs at
Its 81% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 28 W, or about 245 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection. It weighs 47 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 210 cfm
- Net airflow at 0.4 in. w.g.
- 206 cfm
- SRE at 0 °C (64 cfm)
- 81%
- SRE at −25 °C (83 cfm)
- 67%
- ASE at 0 °C
- 84%
- Power draw
- 28 W
- Efficacy
- 2.3 cfm/W
- Type
- ERV
- Connection
- Top ports
- Duct collars
- 6 in
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- Washable MERV 8 filter included; optional disposable MERV 13 filter (V243001)
- Dimensions (L × D × H)
- 24.81 × 21 × 21.69 in
- Weight
- 47 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005445
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005445). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 28 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
With 210 cfm at 0.2 in., and still 206 cfm at 0.4 in., the V210E75RT shares with its side-port version the highest airflow among the ERVs of the Broan-NuTone AI Series. At that level, the duct system becomes the real question. Above 200 cfm, with long runs or many elbows, the manufacturer recommends 8-in. ducts rather than 6-in., connected to the ports with 6-to-8-in. transitions, to avoid excessive static pressure.
Top ports, narrower cabinet
All four ducts connect on top and run straight up to the joists. The cabinet is 24.81 in. wide, versus 27.13 in. for the V210E75RS, its side-port version, which helps in a narrow room. The V210E75RS, for its part, is lower, at 19.5 in. versus 21.69 in. Same airflow, same efficiency figures, same 47 lb weight: the choice comes down to the space available, in width or in height.
Listings, and the neighbouring models
The V210E75RT is on NRCan’s ENERGY STAR list, which gives it a sensible recovery efficiency of 66.9% at 82.6 cfm and −25 °C. It is also on the Novoclimat list of July 13, 2026, everywhere in Québec, with the Advanced Touchscreen wall control, the condition set by its spec sheet. On the HRV side, its counterpart in the same cabinet is the V230H75RT, at 231 cfm at 0.2 in., but it must be connected to a drain; with its membrane core, the V210E75RT does not need one. For a smaller ERV, you move to the small cabinet: the V160E75RT delivers 140 cfm at 0.2 in. in 21 × 16.13 × 21.5 in.
What to plan on site
Airflow is set on site, room by room, following the CSA F326 standard. Duct size, on the other hand, is decided at the planning stage: if the required airflow is above 200 cfm and the runs are long or have many elbows, we move to 8-in. ducts. The unit runs on 120 V, weighs 47 lb and uses recirculation defrost. A washable MERV 8 filter is supplied, and a disposable MERV 13 filter (V243001) is available as an option.
Specifications
- Type: ERV (energy recovery ventilator) with a membrane core, Broan-NuTone AI Series
- ENERGY STAR (Canada): Yes (on NRCan’s ENERGY STAR list under the Broan brand, list checked November 12, 2026)
- Novoclimat: on the Novoclimat list of July 13, 2026, everywhere in Québec, with the Advanced Touchscreen wall control
- Net airflow: 210 cfm at 0.2 in.; 206 cfm at 0.4 in. of static pressure
- Sensible recovery efficiency: 81% at 64 cfm and 0 °C (HVI, Section III, No. 2005445); 66.9% at 82.6 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 24.81 × 21 × 21.69 in.
- Weight: 47 lb
- Ducts: 6 in. (8-in. ducts advised above 200 cfm with long runs or many elbows)
- Connection: top
- Drain: not required
- Defrost: recirculation defrost (motorized damper)
- Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V243001)
- HVI listing (Section III): No. 2005445
- Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 5 years on the core. Labour and shipping not covered. Residential use; original invoice required.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote, call us at 514 316-2973 or email us at sales@airgreen.ca.