Broan-NuTone HRV V130H80RT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: V130H80RT
119 cfm net71% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 10 years
01 · Your home

Is it the right size for your home?

It delivers 119 cfm net. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 119 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
71%
At −25 °CCode: 55% minimum
82%
At 0 °CCertified at 36 cfm
Net airflowThe ducts cost it 12 cfm
0.2 in · test bench131 cfm
0.4 in · with ducts119 cfm

$15.62

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

16W
Running continuously
140kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 71% at 65 cfm.

Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 16 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

2.2 cfm/WFan efficacy of 2.2 cfm/W at 36 cfm

Per HVI, at the 36 cfm and 0 °C test point the unit draws 16 W, a fan efficacy of 2.2 cfm per watt; it is also on NRCan's ENERGY STAR list.

+9 ptsMore efficient than the V130H65RT at equal airflow

Same airflow range as the V130H65RT (35 to 131 cfm at 0.2 in), but per the spec sheets its sensible recovery efficiency reaches 77% versus 68% at 64 cfm and 0 °C; at −25 °C, NRCan's ENERGY STAR list gives 71.3% (65 cfm) versus 64.3% (64.4 cfm).

71%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 65 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. The core transfers heat only.

2505428Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−12 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 131 to 119 cfm. Most spec sheets show only the first number, precisely because it looks better.

16 WMeasured at the airflow it actually runs at

Its 82% at 0 °C is certified at 36 cfm, the continuous airflow of a typical home. At that setting it draws 16 W, or about 140 kWh a year.

10 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in ducts, top connection and a condensate drain. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
35 lbUnit weight
21 × 16.13 × 21.5 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
131 cfm
Net airflow at 0.4 in. w.g.
119 cfm
SRE at 0 °C (36 cfm)
82%
SRE at −25 °C (65 cfm)
71%
ASE at 0 °C
87%
Power draw
16 W
Efficacy
2.2 cfm/W
Type
HRV
Connection
Top ports
Duct collars
5 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
Dimensions (L × D × H)
21 × 16.13 × 21.5 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2505428
Warranty — core
10 years
Warranty — motors
5 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505428). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 16 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Broan-NuTone V130H80RT: the V130H65RT’s airflow, nine points more efficiency

On paper, the V130H80RT and the V130H65RT look a lot alike: same 21 × 16.13 × 21.5 in. cabinet, same airflow range of 35 to 131 cfm at 0.2 in., same 5 in. ducts connected on top. The difference is the core. According to both units’ spec sheets, at 64 cfm and 0 °C, the V130H80RT’s sensible recovery efficiency reaches 77%, versus 68% for the V130H65RT. The gap holds in deep cold: NRCan’s ENERGY STAR list gives it 71.3% at 65 cfm and −25 °C, versus 64.3% at 64.4 cfm for the V130H65RT.

What those points change in winter

An HRV transfers heat from the outgoing stale air to the incoming fresh air. The higher its recovery efficiency, the more tempered the fresh air is when it is cold outside. At low airflow, the V130H80RT reaches 82% at 36 cfm and 0 °C according to its HVI file (Section III, No. 2505428). At that same test point, HVI records 16 W, a fan efficacy of 2.2 cfm per watt at 36 cfm. It is on NRCan’s ENERGY STAR list.

Novoclimat everywhere in Quebec

The V130H80RT is on the Novoclimat list of July 13, 2026, everywhere in Quebec, and its spec sheet states the condition: it meets Novoclimat requirements with the Advanced Touchscreen wall control. The V130H65RT, for its part, is listed only for areas below 6,000 degree-days. For a Novoclimat project in an area at 6,000 degree-days or more, the V130H80RT is therefore the one to pick of the two.

More airflow in the same cabinet?

If you need more air than 131 cfm, the V150H75NT goes up to 150 cfm at 0.2 in. and 140 cfm at 0.4 in., in the same cabinet; its ports are 5 in., but above 130 cfm the maker advises 6 in. ducts. But at −25 °C, NRCan’s ENERGY STAR list gives it 63.3% at 63.6 cfm, below the V130H80RT’s 71.3% at 65 cfm, it uses exhaust defrost rather than recirculation, and it is not on the Novoclimat list under the Broan brand. In the other direction, the V110H65RT tops out at 112 cfm at 0.2 in.

What to plan on site

At commissioning, we adjust the airflow for each room following the CSA F326 standard. Its net airflow is 131 cfm at 0.2 in. and 119 cfm at 0.4 in. of static pressure. It connects on top with 5 in. ducts, requires a drain nearby, runs on 120 V and defrosts by recirculation, using a motorized damper. It ships with a washable MERV 8 filter; a disposable MERV 13 filter (V242851) or a HEPA-type media filter (V25000) is available as an option.

Specifications

  • Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
  • ENERGY STAR (Canada): Yes, on NRCan’s ENERGY STAR list
  • Novoclimat: on the July 13, 2026 list, everywhere in Quebec, with the Advanced Touchscreen wall control (spec sheet condition)
  • Net airflow: 131 cfm at 0.2 in.; 119 cfm at 0.4 in.
  • Sensible recovery efficiency: 77% at 64 cfm and 0 °C (spec sheet); 82% at 36 cfm and 0 °C (HVI); 71.3% at 65 cfm and −25 °C (NRCan ENERGY STAR list, Nov. 12, 2026)
  • Fan efficacy: 2.2 cfm/W at 36 cfm (HVI)
  • Voltage: 120 V, 60 Hz
  • Dimensions (W × D × H): 21 × 16.13 × 21.5 in.
  • Weight: 35 lb
  • Ducts: 5 in. diameter
  • Connection: top ports
  • Drain: required
  • Defrost: recirculation (motorized damper)
  • Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
  • HVI listing (Section III): No. 2505428
  • Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.

Sold and installed by AirGreen.

We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. Reach us at 514 316-2973 or sales@airgreen.ca.