Broan-NuTone HRV V150H75NT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 140 cfm net. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 140 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$17.57
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 63% at 64 cfm.
Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 18 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
6 inMove to 6-in ducts above 130 cfm
This HRV has 5-in ports, but the maker advises 6-in ducts when the required airflow exceeds 130 cfm; 5-to-6-in transitions are then taped onto the ports. This keeps static pressure in check.
HEPAHEPA filtration possible in place of MERV 8
Besides the original washable MERV 8 filter, the sheet lists a disposable MERV 13 filter (V242851) or a HEPA-type media filter (V25000). Either one takes the place of the MERV 8 filter and fits over the core.
63%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 64 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. The core transfers heat only.
2505430Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−10 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 150 to 140 cfm. Most spec sheets show only the first number, precisely because it looks better.
18 WMeasured at the airflow it actually runs at
Its 82% at 0 °C is certified at 36 cfm, the continuous airflow of a typical home. At that setting it draws 18 W, or about 158 kWh a year.
10 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, top connection and a condensate drain. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 150 cfm
- Net airflow at 0.4 in. w.g.
- 140 cfm
- SRE at 0 °C (36 cfm)
- 82%
- SRE at −25 °C (64 cfm)
- 63%
- ASE at 0 °C
- 88%
- Power draw
- 18 W
- Efficacy
- 2.0 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 5 in
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
- Dimensions (L × D × H)
- 21 × 16.13 × 21.5 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505430
- Warranty — core
- 10 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505430). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 18 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
What sets the V150H75NT apart from its AI Series neighbours does not show on the dimension sheet: it is the way it defrosts. This HRV uses exhaust defrost, which the maker also describes as defrost by negative pressure. During the cycle, the supply blower shuts down while the exhaust blower keeps running. The V130H65RT, just below it in the lineup, and the V160H65RT, just above it, use recirculation defrost instead, with a motorized damper.
Otherwise, it is an HRV with 5-in. top ports that delivers 150 cfm at 0.2 in. and 140 cfm at 0.4 in. of static pressure, in a 21 × 16.13 × 21.5 in. cabinet.
Between the V130H65RT and the V160H65RT
In the AI Series, the V150H75NT holds the 150 cfm step. The V130H65RT tops out at 131 cfm at 0.2 in. with the same 5-in. ports, and the V160H65RT goes up to 159 cfm but moves to 6-in. ports. So the V150H75NT keeps 5-in. ports at an airflow where the maker already advises 6-in. ducts, whenever the required airflow exceeds 130 cfm. In that case, 5-to-6-in. transitions are taped onto the ports to keep static pressure in check.
It also has a side-port twin, the V150H75NS, with the same airflow, the same efficiency figures and the same exhaust defrost, but lower (19.13 in. versus 21.5 in.) and wider (23.38 in. versus 21 in.). And the same top-port cabinet comes as an ERV: the V150E75NT delivers 138 cfm at 0.2 in. and needs no drain, whereas the V150H75NT requires one.
Efficiency, figures and sources
Per its HVI listing, the V150H75NT has a sensible recovery efficiency of 82% at 0 °C, measured at 36 cfm. For −25 °C, we go by NRCan’s ENERGY STAR list, where it is listed with 63.3% at 63.6 cfm. On that same list, the V160H80RT reaches 70.0% at 65 cfm. If cold-weather performance weighs heavily in your choice, that is the comparison to make.
What we plan for on site
- Airflow: set on site, room by room, following CSA F326.
- Ducts: 5 in. straight onto the ports, or 6 in. with transitions if the required airflow exceeds 130 cfm.
- Drain: required for this HRV, to be planned near the chosen location.
- Filtration: the washable MERV 8 filter is supplied. For finer filtration, a disposable MERV 13 filter (V242851) or a HEPA-type media filter (V25000) takes its place, over the core.
Specifications
- Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
- ENERGY STAR (Canada): Yes, on NRCan’s ENERGY STAR list (checked November 12, 2026)
- Net airflow: 150 cfm at 0.2 in.; 140 cfm at 0.4 in. of static pressure
- Sensible recovery efficiency: 82% at 36 cfm and 0 °C (HVI); 63.3% at 63.6 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 21 × 16.13 × 21.5 in.
- Weight: 35 lb
- Ducts: 5-in. ports (6-in. ducts advised above 130 cfm)
- Connection: top
- Drain: required
- Defrost: exhaust defrost (the supply blower stops, exhaust continues)
- Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
- HVI certification (Section III): No. 2505430
- Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. To have a V150H75NT installed, call us at 514 316-2973 or email sales@airgreen.ca.