Broan-NuTone HRV V160H65RT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: V160H65RT
150 cfm net65% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 10 years
01 · Your home

Is it the right size for your home?

It delivers 150 cfm net. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 150 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
65%
At −25 °CCode: 55% minimum
68%
At 0 °CCertified at 64 cfm
Net airflowThe ducts cost it 9 cfm
0.2 in · test bench159 cfm
0.4 in · with ducts150 cfm

$25.38

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

26W
Running continuously
228kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 65% at 69 cfm.

Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 26 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

AUTOAUTO mode driven by outdoor temperature

Like the whole AI Series, when wired to a dry contact or a thermostat's ventilation output, the unit can follow an automatic schedule: MIN speed from 10 to 25 °C, 40 min/h from −7 to 10 °C, 20 min/h from −25 to −7 °C and 10 min/h below −25 °C.

8 in8 in clearance in front of the door for service

The sheet calls for 8 in of free space in front of the door for maintenance. The unit hangs from the joists on chains or mounts on a wall with 2 or 4 brackets, all supplied, and must be level within 0.25 in.

65%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 69 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. The core transfers heat only.

2505440Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−9 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 159 to 150 cfm. Most spec sheets show only the first number, precisely because it looks better.

26 WMeasured at the airflow it actually runs at

Its 68% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 26 W, or about 228 kWh a year.

10 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

6 inWhat it needs on site

6 in ducts, top connection and a condensate drain. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
35 lbUnit weight
21 × 16.13 × 21.5 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
159 cfm
Net airflow at 0.4 in. w.g.
150 cfm
SRE at 0 °C (64 cfm)
68%
SRE at −25 °C (69 cfm)
65%
ASE at 0 °C
72%
Power draw
26 W
Efficacy
2.5 cfm/W
Type
HRV
Connection
Top ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
Dimensions (L × D × H)
21 × 16.13 × 21.5 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2505440
Warranty — core
10 years
Warranty — motors
5 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505440). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 26 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Broan-NuTone V160H65RT: 159 cfm and 6 in. ducts in the compact cabinet

The V160H65RT uses the same compact 21 × 16.13 × 21.5 in. cabinet as the V110H65RT and V130H65RT, but it changes two things. Its net airflow rises to 159 cfm at 0.2 in. and 150 cfm at 0.4 in., and it connects with 6 in. ducts instead of 5 in. On heat recovery, it stays at the same level as those two models: according to HVI (Section III, No. 2505440), 68% at 64 cfm and 0 °C.

In deep cold, and on the lists

At −25 °C, NRCan’s ENERGY STAR list (Nov. 12, 2026) gives the V160H65RT 64.6% at 69.1 cfm, and the unit is on that list. It is also on the Novoclimat list of July 13, 2026, only for areas below 6,000 degree-days; according to its spec sheet, it meets Novoclimat requirements with the Advanced Touchscreen wall control.

AUTO mode, like the whole AI Series

Like the other units in the AI Series, it can run in AUTO mode. Wired to a dry contact or a thermostat’s ventilation output, it then follows a schedule based on outdoor temperature: MIN speed from 10 to 25 °C, 40 min/h from −7 to 10 °C, 20 min/h from −25 to −7 °C and 10 min/h below −25 °C.

Its neighbours in the series

The V160H80RT keeps the same airflow and the same cabinet but recovers more heat: according to their spec sheets, 77% versus 68% at 64 cfm and 0 °C; on NRCan’s ENERGY STAR list, 70.0% at 65 cfm and −25 °C, versus 64.6% at 69.1 cfm. It is also on the Novoclimat list everywhere in Quebec, again with the Advanced Touchscreen wall control. The V160E75RT, the ERV version, also transfers moisture and needs no drain, but its net airflow stops at 140 cfm at 0.2 in. (133 cfm at 0.4 in.). Beyond 159 cfm, the series moves to the large cabinet: the V180H75RT goes up to 199 cfm at 0.2 in., in 24.81 × 21 × 21.69 in. and 47 lb.

Installation in detail

The sheet calls for 8 in. of clearance in front of the door for maintenance, and we take that into account as soon as we pick the location. The unit hangs from the joists on chains or mounts on a wall with 2 or 4 brackets, all supplied, and must be level within 0.25 in. The 6 in. ducts connect on top, a drain is required, power is 120 V and defrost works by recirculation with a motorized damper. Each airflow is set on site, room by room, following the CSA F326 standard. The washable MERV 8 filter is supplied; a disposable MERV 13 filter (V242851) or a HEPA-type media filter (V25000) is available as an option.

Specifications

  • Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
  • ENERGY STAR (Canada): Yes, on NRCan’s ENERGY STAR list
  • Novoclimat: on the July 13, 2026 list, only for areas below 6,000 degree-days, with the Advanced Touchscreen wall control (spec sheet condition)
  • Net airflow: 159 cfm at 0.2 in.; 150 cfm at 0.4 in.
  • Sensible recovery efficiency: 68% at 64 cfm and 0 °C (HVI); 64.6% at 69.1 cfm and −25 °C (NRCan ENERGY STAR list, Nov. 12, 2026)
  • Voltage: 120 V, 60 Hz
  • Dimensions (W × D × H): 21 × 16.13 × 21.5 in.
  • Weight: 35 lb
  • Ducts: 6 in. diameter
  • Connection: top ports
  • Drain: required
  • Defrost: recirculation (motorized damper)
  • Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
  • HVI listing (Section III): No. 2505440
  • Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.

Sold and installed by AirGreen.

We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. To talk it over, call us at 514 316-2973 or write to sales@airgreen.ca.