Broan-NuTone HRV V180H75RT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 193 cfm net. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 193 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$21.47
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 71% at 83 cfm.
Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 22 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
NovoclimatMeets Novoclimat with the touchscreen control
Paired with the Advanced Touchscreen wall control, this HRV meets Novoclimat requirements, according to the maker. The Novoclimat list of July 13, 2026 accepts it everywhere in Québec, with no degree-day limit, while smaller models in the series, such as the V130H65RT, are listed only below 6,000 degree-days.
200 W200 W maximum, on a standard outlet
Its sheet lists 120 V, 3 A and 200 W maximum, versus 3.6 A and 270 W for the V210 and V230 on the same platform. It plugs into a standard outlet within 6 ft using its 6-ft cord.
71%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. The core transfers heat only.
2505435Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−6 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 199 to 193 cfm. Most spec sheets show only the first number, precisely because it looks better.
22 WMeasured at the airflow it actually runs at
Its 78% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 22 W, or about 193 kWh a year.
10 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection and a condensate drain. It weighs 47 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 199 cfm
- Net airflow at 0.4 in. w.g.
- 193 cfm
- SRE at 0 °C (64 cfm)
- 78%
- SRE at −25 °C (83 cfm)
- 71%
- ASE at 0 °C
- 82%
- Power draw
- 22 W
- Efficacy
- 2.9 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- Washable MERV 8 filter included; optional disposable MERV 13 filter (V243001)
- Dimensions (L × D × H)
- 24.81 × 21 × 21.69 in
- Weight
- 47 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505435
- Warranty — core
- 10 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505435). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 22 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
In the AI Series’ large cabinet, the V180H75RT is the 199 cfm HRV, one step below the V230H75RT. Same format, same 6-in top ports, but it asks less of the electrical side. Its sheet lists 120 V, 3 A and 200 W maximum, versus 3.6 A and 270 W for the 210 and 230 cfm models on the same platform. For the hookup, we plan a standard outlet within reach of its 6-ft cord.
Novoclimat: a condition written on the sheet
The V180H75RT is on the Novoclimat list of July 13, 2026, everywhere in Québec. Its spec sheet does set a condition: it meets the program’s requirements with the Advanced Touchscreen wall control. In a Novoclimat project, the unit and that control therefore go together; one without the other does not match what the sheet says.
Reading its efficiency figures
Its HVI listing gives 78% at 0 °C, measured at 64 cfm. Beware of quick comparisons: the 82% that HVI gives the V150H75NT or the V160H75RS is measured at 36 cfm, an airflow almost half as high. At −25 °C, the NRCan ENERGY STAR list, which includes it, shows 71.2% at 82.8 cfm.
The ERV for this cabinet, and the neighbouring sizes
For an ERV in this same cabinet, we offer the V210E75RT, rated 210 cfm at 0.2 in, with no drain required and a place on the NRCan ENERGY STAR list. The V180E75RT, the 189 cfm ERV on the same platform, is not on the ENERGY STAR list under the Broan brand, and Broan-NuTone no longer presents it in its current lineup. The V180H75RT is on the list and needs a drain. Above it, the V230H75RT goes up to 231 cfm at 0.2 in in the same format; below it, the V160H65RT delivers 159 cfm in a 21 × 16.13 × 21.5 in cabinet.
What we prepare before installation
- Outlet: a standard outlet within 6 ft of the unit.
- Drain: required for this HRV.
- Ducts: 6 in, connected on top, on a 47 lb unit.
- Airflow: set on site, room by room, following CSA F326.
- Filters: a washable MERV 8 is supplied; a disposable MERV 13 filter (V243001) is available as an option.
Specifications
- Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
- ENERGY STAR (Canada): Yes, on the NRCan ENERGY STAR list (checked November 12, 2026)
- Net airflow: 199 cfm at 0.2 in of static pressure; 193 cfm at 0.4 in
- Sensible recovery efficiency: 78% at 64 cfm and 0 °C (HVI); 71.2% at 82.8 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 24.81 × 21 × 21.69 in
- Weight: 47 lb
- Ducts: 6 in diameter
- Connection: top
- Drain: required
- Defrost: recirculation defrost (motorized damper)
- Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V243001)
- HVI certification (Section III): No. 2505435
- Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote on the V180H75RT, reach us at 514 316-2973 or sales@airgreen.ca.