Broan-NuTone ERV V210E75RS Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: V210E75RS
206 cfm net2,400 to 3,900 sq ft65% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 206 cfm net, enough to ventilate 2,400 to 3,900 sq ft. Choose your home's living area.

It's the right size.

For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 206 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
65%
At −25 °CCode: 54% minimum
81%
At 0 °CCertified at 64 cfm
Net airflowThe ducts cost it 4 cfm
0.2 in · test bench210 cfm
0.4 in · with ducts206 cfm

$27.33

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

28W
Running continuously
245kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 65% at 83 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 28 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

19.5 inSide ports: 19-1/2 in high instead of 21-11/16

The ducts connect on the sides, so this ERV is only 19-1/2 in high, versus 21-11/16 in for the top-port V210E75RT. In exchange it is 27-1/8 in wide. Handy under low joists.

ProtectionAutomatic protection of the core membrane

If auto-balancing reaches no more than 160 cfm, a sign of very high static pressure (over 1.3 in w.g.), the unit cuts 30 cfm to avoid deforming the core membrane. Well-sized ducts avoid this limit.

65%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005446Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−4 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 210 to 206 cfm. Most spec sheets show only the first number, precisely because it looks better.

28 WMeasured at the airflow it actually runs at

Its 81% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 28 W, or about 245 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years. We register the warranty in your name at commissioning.

6 inWhat it needs on site

6 in ducts, side connection. It weighs 47 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005446. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

6 in ductsCollar diameter
Side connectionSide ports
47 lbUnit weight
27.13 × 21 × 19.5 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
210 cfm
Net airflow at 0.4 in. w.g.
206 cfm
SRE at 0 °C (64 cfm)
81%
SRE at −25 °C (83 cfm)
65%
ASE at 0 °C
84%
Power draw
28 W
Efficacy
2.3 cfm/W
Type
ERV
Connection
Side ports
Duct collars
6 in
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter and washable exhaust filter included; optional disposable MERV 13 filter (V24300)
Dimensions (L × D × H)
27.13 × 21 × 19.5 in
Weight
47 lb
Power supply
120 V
HVI certification (Section III)
2005446
Warranty — core
5 years
Warranty — motors
5 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005446). Annual consumption calculated at 28 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Broan V180E75RTSmaller2,100 to 3,400 sq ft182 cfm
Broan-NuTone V210E75RSYou are here2,400 to 3,900 sq ft206 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Broan-NuTone V210E75RS – Energy Star VRE Air Exchanger 210 CFM

At AirGreen, we know that an efficient air exchanger plays a crucial role in home comfort. Good ventilation allows for renewing indoor air, reducing excess humidity, removing odors, improving air quality, and maintaining a healthier environment for the whole family. That’s why we highlight the Broan-NuTone V210E75RS, a Powerful, efficient residential VRE well suited for modern Quebec homes.

With a capacity of 210 CFM at 0.4”, a maximum sensible recovery efficiency of 81%, a certification Energy Star and a side connection, the Broan-NuTone V210E75RS is a reliable ventilation solution for residences that require effective and constant air renewal.

A VRE air exchanger designed for residential comfort

The Broan-NuTone V210E75RS is a type of air exchanger VRE, that is to say a energy recovery ventilator. This type of device allows for extracting stale air from the home while introducing fresh air from outside. The main advantage of a VRE is that it helps recover some of the energy contained in the outgoing air, which helps limit energy losses related to ventilation.

In a well-insulated home, indoor air can quickly become laden with humidity, particles, odors, or contaminants. The V210E75RS helps maintain a more balanced environment by ensuring controlled air exchange. For homeowners located in Montreal, Laval, Longueuil, on the North Shore or the South Shore, this model represents an interesting option to improve indoor comfort throughout the year.

Why choose the Broan-NuTone V210E75RS?

The Broan-NuTone V210E75RS stands out for its combination of power, efficiency, and practical design. It is especially suited for residential projects where indoor air quality is a priority.

Powerful airflow of 210 CFM: with a capacity of 210 CFM at 0.4”, this model offers efficient ventilation for homes that require a higher air exchange rate.

Energy Star Certification: the V210E75RS is certified Energy Star, which confirms that it meets high energy efficiency standards. This is an important advantage for homeowners who want to improve ventilation without neglecting energy consumption.

Maximum sensible recovery efficiency of 81%: this performance allows recovering part of the energy from the expelled air, thus contributing to better overall efficiency of the ventilation system.

Side connection: the connection side facilitates integration in various installation configurations, especially in mechanical rooms, basements, or spaces where ducts need to be positioned more compactly.

Recirculation defrost cycle: the defrost system by recirculation is an important asset for Quebec’s climate. It helps the device maintain stable operation during cold periods.

Practical format: with dimensions of 27.13 × 21.00 × 19.50 inThe V210E75RS offers high capacity while maintaining a well-designed format for residential installation.

A solution adapted to Quebec’s climate

In Quebec, an air exchanger must be able to operate under very variable conditions. Cold winters, humid periods, hot summers, and increasingly airtight homes make mechanical ventilation essential.

The Broan-NuTone V210E75RS It meets these needs well thanks to its efficiency, high airflow, and recirculation defrost cycle. It allows for renewing indoor air without simply expelling the energy already used to heat or cool the house.

For a home equipped with a heating system, a central heat pump, a wall system, or a duct network, a well-chosen ERV can contribute to a better overall balance of indoor comfort.

Technical specifications of the Broan-NuTone V210E75RS

Here are the main technical details to remember for this model:

Model: Broan-NuTone V210E75RS
Type of air exchanger: ERV
Energy Star Certification: Yes
Voltage: 115 V
Airflow: 210 PCM / CFM at 0.4”
Maximum sensible recovery efficiency: 81%
Connection: Side
Defrost cycle: Recirculation
Dimensions: 27.13 × 21.00 × 19.50 in
Manufacturer's warranty: 5-1-0

These features make it a robust and efficient model for residential installations that require effective ventilation, especially in homes where indoor air quality is a priority.

Better air quality every day

A good air exchanger helps reduce several common discomforts in homes: excessive humidity, window condensation, persistent odors, stagnant air, and a heavy air feeling. The Broan-NuTone V210E75RS helps to continuously or controllably renew the air, depending on the system configuration and the residence's needs.

In modern homes, insulation and airtightness are often very effective. However, this also means that indoor air circulates less naturally. A system like the V210E75RS allows fresh air to be brought in without unnecessarily compromising thermal comfort.

Professional installation by AirGreen

Choosing a good air exchanger is important, but its installation is just as crucial. A high-performance device can lose much of its efficiency if it is poorly installed, unbalanced, or improperly connected. At AirGreen, we place great importance on the quality of the installation, duct configuration, and system integration within the home's overall HVAC network.

Our teams operate in Montreal, Laval, Longueuil, on the South Shore and the North Shore to provide neat installations tailored to the real needs of customers. Every home is different, which is why we take the time to assess the available space, the type of connection, the required airflow, and technical constraints before recommending a solution.

An ideal device for well-insulated homes

The Broan-NuTone V210E75RS is particularly interesting for homes with high airtightness. In this type of dwelling, outdoor air enters less naturally, which can improve energy efficiency but also create a greater need for mechanical ventilation.

Thanks to its capacity of 210 CFM, this model can meet higher ventilation needs. It helps maintain better air circulation while contributing to the overall comfort of the home.

Maintenance and durability

Like any air exchanger, the Broan-NuTone V210E75RS must be regularly maintained to preserve its performance. Proper maintenance helps extend the device's lifespan, maintain good airflow, and ensure better indoor air quality.

It is recommended to check and clean filters, inspect air vents, ensure ducts are not blocked, and have the system checked by a professional if needed. At AirGreen, we can also support our clients with the maintenance and optimization of their ventilation system.

Why trust AirGreen?

AirGreen specializes in heating, air conditioning, heat pumps, ventilation, and HVAC solutions in Greater Montreal. Our approach is based on honest advice, professional installation, and close attention to technical details.

We are not just looking to install a device. We want to offer a solution adapted to the home, the occupants' lifestyle, and Quebec's climatic conditions. With the Broan-NuTone V210E75RS, we provide a high-performance ventilation solution for owners who want to improve their indoor comfort and air quality.

Conclusion

The Broan-NuTone V210E75RS is an excellent choice for residences that require a powerful, efficient, and reliable air exchanger. Thanks to its flow rate of 210 CFM, its maximum sensible recovery efficiency of 81%, its certification Energy Star, its side connection and its defrost cycle by recirculation, it meets the needs of Quebec homes very well.

For owners of Montreal, Laval, Longueuil, the North Shore, and the South Shore, this model represents a serious solution to improve ventilation, reduce stagnant air, and promote a healthier indoor environment.

At AirGreen, we are ready to assist you in choosing, installing, and maintaining your air exchanger to ensure optimal performance year after year.