Broan-NuTone HRV V230H75RS Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 225 cfm net. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 225 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$24.40
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 71% at 80 cfm.
Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 25 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
19.5 inSide-port version, 19.5 in high
This 231 cfm HRV has its four 6-in ports on the sides: it is only 19.5 in high, versus 21.69 in for the V230H75RT, but 27.13 in wide. Useful under a low ceiling.
40 °CCooling fan for the electronics
Like every 210 and 230 cfm model in the AI Series, this HRV has a fan in the electrical box that can start if the ambient air exceeds 40 °C. The maker asks for 3 in of clearance on that side for cooling and servicing.
71%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 80 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. The core transfers heat only.
2505437Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−6 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 231 to 225 cfm. Most spec sheets show only the first number, precisely because it looks better.
25 WMeasured at the airflow it actually runs at
Its 78% at 0 °C is certified at 66 cfm, the continuous airflow of a typical home. At that setting it draws 25 W, or about 219 kWh a year.
10 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, side connection and a condensate drain. It weighs 47 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 231 cfm
- Net airflow at 0.4 in. w.g.
- 225 cfm
- SRE at 0 °C (66 cfm)
- 78%
- SRE at −25 °C (80 cfm)
- 71%
- ASE at 0 °C
- 82%
- Power draw
- 25 W
- Efficacy
- 2.6 cfm/W
- Type
- HRV
- Connection
- Side ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- Washable MERV 8 filter included; optional disposable MERV 13 filter (V243001)
- Dimensions (L × D × H)
- 27.13 × 21 × 19.5 in
- Weight
- 47 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505437
- Warranty — core
- 10 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505437). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 25 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The V230H75RS puts the highest airflow in the AI Series, 231 cfm at 0.2 in, into the side-port version of the large cabinet. Its four 6-in ports exit on the sides, so it is only 19.5 in high, instead of 21.69 in for the V230H75RT. In exchange, it takes more room in width, at 27.13 in versus 24.81 in for the top-port version.
Efficiency and listings
At 0 °C, its HVI listing shows 78% at 66 cfm, while at −25 °C, the NRCan ENERGY STAR list, which includes it, gives 71.4% at 80.3 cfm. These are exactly the values listed for the V230H75RT: moving to side ports changes nothing in those figures. It is also on the Novoclimat list of July 13, 2026, everywhere in Québec, with the Advanced Touchscreen wall control, the condition stated on its spec sheet.
HRV or ERV, and the smaller side-port model
This low, wide cabinet also comes as an ERV with the V210E75RS, rated 210 cfm at 0.2 in with no drain required, whereas the V230H75RS, as an HRV, needs one. For a more modest maximum airflow, still with side ports, the V160H75RS delivers 159 cfm at 0.2 in in a 23.38 × 16.13 × 19.13 in cabinet.
To plan on site
- Footprint: 27.13 in wide by 19.5 in high, plus room for the ducts coming in on the sides.
- Clearance: as on the other 210 and 230 cfm models, a fan in the electrical box can start if the ambient air exceeds 40 °C; the maker asks for 3 in of free space on that side.
- Drain: required.
- Airflow: set on site, room by room, following CSA F326.
- Filters: washable MERV 8 included; disposable MERV 13 (V243001) optional.
Specifications
- Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
- ENERGY STAR (Canada): Yes, on the NRCan ENERGY STAR list (checked November 12, 2026)
- Net airflow: 231 cfm at 0.2 in of static pressure; 225 cfm at 0.4 in
- Sensible recovery efficiency: 78% at 66 cfm and 0 °C (HVI); 71.4% at 80.3 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 27.13 × 21 × 19.5 in
- Weight: 47 lb
- Ducts: 6 in diameter
- Connection: side
- Drain: required
- Defrost: recirculation defrost (motorized damper)
- Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V243001)
- HVI certification (Section III): No. 2505437
- Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a V230H75RS, call us at 514 316-2973 or write to sales@airgreen.ca, with a plan or photos of the space if you have them.