Fantech ERV ATMO 300E-EC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: ATMO 300E-EC
301 cfm net3,600 to 5,700 sq ft63% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 301 cfm net, enough to ventilate 3,600 to 5,700 sq ft. Choose your home's living area.

It's the right size.

For a 3,200 to 5,000 sq ft home, about 215 cfm of air needs to be renewed continuously. This unit delivers 301 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
63%
At −25 °CCode: 54% minimum
77%
At 0 °CCertified at 64 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench320 cfm
0.4 in · with ducts301 cfm

$30.26

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

31W
Running continuously
272kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 63% at 64 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 31 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

300 cfmOnly ATMO with EC motors: up to 300 cfm

The ATMO 300E-EC is the only ATMO model with electronically commutated motors. In the ATMO 200 cabinet, it covers 80 to 300 cfm at 0.4 in, versus 60 to 200 cfm for the ATMO 200E, and Fantech's guide gives it 2.0 cfm/W, the highest in the series.

22 inCore removal: 22 in in front of the door

The ATMO 300E-EC's core comes out through the front door, held by two latches under the unit. Fantech calls for 22 in (559 mm) free in front of the unit to pull it out, and 2 3/8 in above the electrical box for wiring.

63%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 64 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005194Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 320 to 301 cfm.

31 WMeasured at the airflow it actually runs at

Its 77% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 31 W, or about 272 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

6 inWhat it needs on site

6 in ducts, side connection. It weighs 60 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005194) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Side connectionSide ports
60 lbUnit weight
23.88 × 16.94 × 21.44 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
320 cfm
Net airflow at 0.4 in. w.g.
301 cfm
SRE at 0 °C (64 cfm)
77%
SRE at −25 °C (64 cfm)
63%
ASE at 0 °C
80%
Power draw
31 W
Efficacy
2.1 cfm/W
Type
ERV
Connection
Side ports
Duct collars
6 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters; optional MERV 8 (463945) and MERV 13 (463946)
Dimensions (L × D × H)
23.88 × 16.94 × 21.44 in
Weight
60 lb
Power supply
120 V
HVI certification (Section III)
2005194
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005194). Annual consumption calculated at 31 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Fantech ATMO 200ESmaller2,400 to 3,800 sq ft201 cfm
Fantech ATMO 300E-ECYou are here3,600 to 5,700 sq ft301 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The only ATMO with EC motors, up to 301 cfm

For a large home that needs an energy recovery ventilator (ERV), the Fantech ATMO 300E-EC offers the highest airflow in the ATMO and HERO series: 301 cfm net at 0.4 in., and 320 cfm at 0.2 in.

It is also the only ATMO model with electronically commutated motors. It fits in the same cabinet as the ATMO 200 units, with side connections and a height of 21.44 in.

From 80 to 300 cfm in the ATMO 200 cabinet

Fantech's selection guide gives the ATMO 300E-EC a range of 80 to 300 cfm at 0.4 in., versus 60 to 200 cfm for the ATMO 200E. Its fan efficiency there is 2.0 cfm/W, the highest in the ATMO series.

In HVI testing, it draws 31 W at 64 cfm, or 2.1 cfm/W at that point. Running continuously, that comes to about 272 kWh per year, roughly $30 at Hydro-Québec Rate D (11.142¢/kWh). The ATMO 200E, with conventional motors, is estimated at about $51 per year for a lower maximum airflow.

For a large home, this often avoids installing two air exchangers, and a single unit with EC motors costs less to run.

Recovery efficiency

According to HVI, sensible recovery efficiency is 77% at 64 cfm and 0 °C, and adjusted sensible efficiency is 80%. At −25 °C, it remains at 63% at the same airflow of 64 cfm, above the 54% threshold of section 9.32 of the Québec Construction Code for Greater Montreal. In cooling mode, Fantech's guide gives a total efficiency of 68%, the highest of the ATMO units.

An ERV core also transfers part of the moisture: the air in a large home stays less dry in winter. Defrost works by stopping the supply fan, while the exhaust fan switches to high speed.

Core removal: 22 in. in front of the door

The core comes out through the front door, which is held by two latches at the bottom of the unit. Fantech calls for 22 in. of clear space in front of the unit to remove it, and 2 3/8 in. above the electrical box for wiring.

Installation

  • Dimensions: 23.88 × 16.94 × 21.44 in. (L × D × H)
  • Weight: 60 lb
  • Connections: 6 in., round, side, with sliding ISF collars
  • Power supply: 120 V
  • Drain: optional, depending on the climate

The drain is required only where it is usually below −25 °C outside and where indoor humidity exceeds 40% for 24 to 96 hours; otherwise, the supplied plug closes the fitting. The unit hangs with chains or mounts on the wall. With the collars, it is 29 1/2 in. wide overall.

At this airflow, the duct system matters as much as the unit: short ducts, 45° elbows and Y fittings rather than T fittings, as the manual recommends.

Fantech recommends a fully dedicated installation, with its own ducts, to limit electricity consumption. With EC motors, that is the approach we prefer. The ISF collars come off by sliding them toward the door, which makes it possible to fasten each duct before putting the collar back with the supplied screws.

Filters

Two washable electrostatic MERV 3 filters are supplied, to be washed in warm soapy water. Optional: MERV 8 (463945) and MERV 13 (463946). A finer filter reduces airflow; we plan for it in the calculation.

Warranty

Fantech warrants the core for 5 years, the fan motors for 7 years and the electrical components for 5 years. The unit is designed for residential use only.

The ATMO 300E-EC is certified in section III of the HVI directory (number 2005194): its airflows and efficiencies are published and can be checked by anyone. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already opened under the program's transition rules.

Installation by AirGreen in Greater Montreal

For a home of this size, we do the room-by-room ventilation calculation under the CSA F326 standard, then we design the duct system so that the ATMO 300E-EC delivers the required airflow to each room.

At commissioning, we balance supply and exhaust with a manometer, to the calculated airflow. We install in Montreal, Laval, Longueuil, the North Shore and the South Shore.

For a free quote: 514 316-2973 or sales@airgreen.ca.