Fantech ERV ATMO 200E Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 201 cfm net, enough to ventilate 2,400 to 3,800 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 201 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$50.75
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 66 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 52 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
15–20%A MERV 13 filter cuts airflow by 15 to 20%
Fantech offers optional MERV 8 (463945) and MERV 13 (463946) filters for the ATMO 200E. Per its filter guide, going from MERV 3 to MERV 8 typically reduces airflow by 10 to 15%, and to MERV 13 by 15 to 20%; the added static pressure must be planned for in the design.
DrainDrain optional depending on climate
The ATMO 200E comes with a drain fitting and a drain cap. Fantech requires the drain tube only where it is usually below −25 °C outdoors and indoor humidity exceeds 40% for 24 to 96 hours; otherwise the cap closes the fitting.
60%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005013Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−32 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 233 to 201 cfm.
52 WMeasured at the airflow it actually runs at
Its 75% at 0 °C is certified at 66 cfm, the continuous airflow of a typical home. At that setting it draws 52 W, or about 456 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
6 inWhat it needs on site
6 in ducts, side connection. It weighs 57 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005013) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 233 cfm
- Net airflow at 0.4 in. w.g.
- 201 cfm
- SRE at 0 °C (66 cfm)
- 75%
- SRE at −25 °C (66 cfm)
- 60%
- ASE at 0 °C
- 81%
- Power draw
- 52 W
- Efficacy
- 1.3 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 6 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters; optional MERV 8 (463945) and MERV 13 (463946)
- Dimensions (L × D × H)
- 23.88 × 16.94 × 21.44 in
- Weight
- 57 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005013
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005013). Annual consumption calculated at 52 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A 201 cfm ERV with a real choice of filtration
The Fantech ATMO 200E is a side-port energy recovery ventilator (ERV) for family homes. It delivers a net airflow of 201 cfm at 0.4 in., and 233 cfm at 0.2 in. It transfers heat and part of the moisture, which keeps the air less dry in winter.
For a family that includes someone with allergies or asthma, the question of filters comes up quickly. The ATMO 200E accepts optional MERV 8 and MERV 13 filters, and Fantech clearly publishes what that choice costs in airflow.
MERV 13: 15 to 20% less airflow
The unit comes with two washable electrostatic MERV 3 filters. Fantech offers optional MERV 8 (463945) and MERV 13 (463946) filters. According to its filter guide, going from MERV 3 to MERV 8 usually reduces airflow by 10 to 15%, and to MERV 13 by 15 to 20%.
Fantech asks that the added static pressure be taken into account at the design stage. In practice, with a MERV 13, the unit must be selected and set to deliver the required airflow despite that loss. That is why we choose the filters before balancing, not after.
Optional drain, depending on the climate
The ATMO 200E comes with a drain fitting and a drain plug. Fantech calls for the drain tube only where it is usually below −25 °C outside and where indoor humidity exceeds 40% for 24 to 96 hours. Otherwise, the plug closes the fitting, and the unit can be installed away from a floor drain.
Efficiency and power consumption
According to HVI, sensible recovery efficiency is 75% at 66 cfm and 0 °C, and adjusted sensible efficiency is 81%. At −25 °C, it remains at 60% at the same airflow of 66 cfm, above the 54% threshold of section 9.32 of the Québec Construction Code for Greater Montreal. In cooling mode, Fantech's guide gives a total efficiency of 65%.
At the 66 cfm test point, it draws 52 W, or 1.3 cfm/W. Running continuously, that comes to about 456 kWh per year, roughly $51 at Hydro-Québec Rate D (11.142¢/kWh).
Defrost works by stopping the supply fan: fresh air stops coming in and the exhaust fan switches to high speed to clear the core.
Installation
- Dimensions: 23.88 × 16.94 × 21.44 in. (L × D × H)
- Weight: 57 lb
- Connections: 6 in., round, side, with sliding ISF collars
- Power supply: 120 V
- Drain: optional, depending on the climate
The unit hangs from the ceiling with chains or mounts on the wall on the bracket. Fantech calls for 22 in. of clear space in front of the unit to remove the core, and 2 3/8 in. above the electrical box. With the collars, it is 29 1/2 in. wide overall. To maintain airflow, the manual recommends short ducts, 45° elbows and Y fittings.
The ISF collars come off by sliding them toward the door. You fasten the duct to the collar, then put the collar back in place with the supplied screws, the only ones Fantech allows.
Maintenance
The core comes out through the front door, which is held by two latches. The MERV 3 filters wash in warm soapy water. With a finer filter, keep a closer eye on how dirty it gets: a loaded filter reduces airflow even further.
Warranty
Fantech warrants the core for 5 years, the fan motors for 7 years and the electrical components for 5 years. The unit is designed for residential use only.
The ATMO 200E is certified in section III of the HVI directory (number 2005013): its airflows and efficiencies are published and can be checked by anyone. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or an ERV; only files already opened under the program's transition rules remain eligible.
Installation by AirGreen in Greater Montreal
We establish the required airflow room by room under the CSA F326 standard, then we choose the filter with you. The calculation includes the airflow loss of the chosen filter, so that the home really receives the planned amount of air.
At commissioning, we balance the unit with a manometer with the filters in place, to the calculated airflow. We install in Montreal, Laval, Longueuil, the North Shore and the South Shore.