Fantech ERV ATMO 150E Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 161 cfm net, enough to ventilate 1,900 to 3,000 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 161 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$50.75
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 64 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 52 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
0.8 inDesigned for higher static pressure
Fantech aims the ATMO 150E at higher static pressure applications. Its sheet lists net airflow up to 0.8 in: 189 cfm at 0.2 in, 161 cfm at 0.4 in and still 104 cfm at 0.8 in.
DrainDrain optional depending on climate
The ATMO 150E comes with a drain fitting and a drain cap. Fantech requires the drain tube only where it is usually below −25 °C outdoors and indoor humidity exceeds 40% for 24 to 96 hours; otherwise the cap closes the fitting.
60%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 64 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005030Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−28 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 189 to 161 cfm.
52 WMeasured at the airflow it actually runs at
Its 75% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 52 W, or about 456 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
6 inWhat it needs on site
6 in ducts, side connection. It weighs 51 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005030) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 189 cfm
- Net airflow at 0.4 in. w.g.
- 161 cfm
- SRE at 0 °C (64 cfm)
- 75%
- SRE at −25 °C (64 cfm)
- 60%
- ASE at 0 °C
- 81%
- Power draw
- 52 W
- Efficacy
- 1.2 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 6 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (10 × 11 7/8 in); optional MERV 8 (463943) and MERV 13 (463944)
- Dimensions (L × D × H)
- 23.88 × 11.94 × 21.44 in
- Weight
- 51 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005030
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005030). Annual consumption calculated at 52 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
An ERV designed for long duct runs
Fantech aims the ATMO 150E at installations where static pressure is higher than average. This energy recovery ventilator (ERV) delivers a net airflow of 161 cfm at 0.4 in., and 189 cfm at 0.2 in. It is the air exchanger to look at when the ducts are long, with several elbows, or when they have to cross two floors.
Airflow published up to 0.8 in.
Most sheets stop at 0.4 in. The ATMO 150E's sheet publishes net airflow up to 0.8 in.: 189 cfm at 0.2 in., 174 cfm at 0.3 in., 161 cfm at 0.4 in. and still 104 cfm at 0.8 in.
For you, this means we can check on paper what the unit will actually deliver in your home, once the duct system and the filters have been calculated. If the pressure in your duct system is high, we know in advance how much airflow remains available, instead of finding out during balancing.
Optional drain, depending on the climate
The ATMO 150E comes with a drain fitting and a drain plug. Fantech calls for the drain tube only where it is usually below −25 °C outside and where indoor humidity exceeds 40% for 24 to 96 hours. Otherwise, the plug closes the fitting.
In most homes in Montreal, Longueuil or the North Shore, we assess these conditions with you. When the drain is not needed, the unit can go where there is no floor drain.
Efficiency and power consumption
The ERV core is made of a polymer membrane that is highly permeable to water vapour; it measures 12 × 12 in. with a 10 in. depth. It transfers heat and part of the moisture, and Fantech describes it as frost-tolerant and washable with water.
According to HVI, sensible recovery efficiency is 75% at 64 cfm and 0 °C, and adjusted sensible efficiency is 81%. At −25 °C, it remains at 60% at the same airflow of 64 cfm, above the 54% threshold of section 9.32 of the Québec Construction Code for Greater Montreal. In cooling mode, the sheet gives a total efficiency of 60% at 64 cfm.
At the 64 cfm test point, it draws 52 W, or 1.2 cfm/W. Running continuously, that comes to about 456 kWh per year, roughly $51 at Hydro-Québec Rate D (11.142¢/kWh).
Defrost starts at −10 °C and below: the supply fan stops and the exhaust fan switches to high speed, then the unit returns to normal operation.
Installation
- Dimensions: 23.88 × 11.94 × 21.44 in. (L × D × H)
- Weight: 51 lb
- Connections: 6 in., round, side, with sliding ISF collars
- Power supply: 120 V
- Drain: optional, depending on the climate
The unit mounts on the wall with the bracket or hangs from the ceiling with chains. Fantech calls for 17 in. of clear space in front of the unit to remove the core, and 2 3/8 in. above the electrical box. With the collars, the overall width is 29 1/2 in.
Filters
Two washable electrostatic MERV 3 filters, 10 × 11 7/8 in., are supplied, to be washed in warm soapy water. Optional: MERV 8 (463943) and MERV 13 (463944). A finer filter adds static pressure; with the curve published up to 0.8 in., we can measure its effect in advance.
Warranty
Fantech warrants the core for 5 years, the fan motors for 7 years and the electrical components for 5 years. The unit is designed for residential use only.
The ATMO 150E is certified in section III of the HVI directory (number 2005030): its airflows and efficiencies are published and can be checked by anyone. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already opened under the program's transition rules.
Installation by AirGreen in Greater Montreal
The room-by-room calculation of the CSA F326 standard sets the airflow your home needs. We then estimate the static pressure of your duct system and read, on the ATMO 150E's curve, the airflow it will actually deliver.
At commissioning, we balance the unit with a manometer, to the calculated airflow. We install in Montreal, Laval, Longueuil, the North Shore and the South Shore.
For a free quote, call 514 316-2973 or write to sales@airgreen.ca.