Échangeur d'Air Fantech ERV ATMO 150E | Montréal, Laval, Longueuil, Rive Sud et Rive Nord

In stock
SKU: ATMO 150E
161 cfm net1,900 to 3,000 sq ft60% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 161 cfm net, enough to ventilate 1,900 to 3,000 sq ft. Choose your home's living area.

It's the right size.

For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 161 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
60%
At −25 °CCode: 54% minimum
75%
At 0 °CCertified at 64 cfm
Net airflowThe ducts cost it 28 cfm
0.2 in · test bench189 cfm
0.4 in · with ducts161 cfm

$50.75

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

52W
Running continuously
456kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 64 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 52 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

0.8 inDesigned for higher static pressure

Fantech aims the ATMO 150E at higher static pressure applications. Its sheet lists net airflow up to 0.8 in: 189 cfm at 0.2 in, 161 cfm at 0.4 in and still 104 cfm at 0.8 in.

DrainDrain optional depending on climate

The ATMO 150E comes with a drain fitting and a drain cap. Fantech requires the drain tube only where it is usually below −25 °C outdoors and indoor humidity exceeds 40% for 24 to 96 hours; otherwise the cap closes the fitting.

60%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 64 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005030Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−28 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 189 to 161 cfm. Most spec sheets show only the first number, precisely because it looks better.

52 WMeasured at the airflow it actually runs at

Its 75% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 52 W, or about 456 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

6 inWhat it needs on site

6 in ducts, side connection. It weighs 51 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005030. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

6 in ductsCollar diameter
Side connectionSide ports
51 lbUnit weight
23.88 × 11.94 × 21.44 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
189 cfm
Net airflow at 0.4 in. w.g.
161 cfm
SRE at 0 °C (64 cfm)
75%
SRE at −25 °C (64 cfm)
60%
ASE at 0 °C
81%
Power draw
52 W
Efficacy
1.2 cfm/W
Type
ERV
Connection
Side ports
Duct collars
6 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (10 × 11 7/8 in); optional MERV 8 (463943) and MERV 13 (463944)
Dimensions (L × D × H)
23.88 × 11.94 × 21.44 in
Weight
51 lb
Power supply
120 V
HVI certification (Section III)
2005030
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005030). Annual consumption calculated at 52 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Un VRE conçu pour les longs réseaux de conduits

Fantech destine l'ATMO 150E aux installations où la pression statique est plus forte que la moyenne. Ce ventilateur récupérateur d'énergie (VRE) fournit un débit net de 161 pcm à 0,4 po, et 189 pcm à 0,2 po. C'est l'échangeur d'air à regarder quand les conduits sont longs, avec plusieurs coudes, ou qu'ils doivent traverser deux étages.

Le débit publié jusqu'à 0,8 po

La plupart des fiches s'arrêtent à 0,4 po. Celle de l'ATMO 150E publie le débit net jusqu'à 0,8 po : 189 pcm à 0,2 po, 174 pcm à 0,3 po, 161 pcm à 0,4 po et encore 104 pcm à 0,8 po.

Pour vous, cela veut dire que nous pouvons vérifier sur papier ce que l'appareil fournira réellement dans votre maison, une fois le réseau de conduits et les filtres calculés. Si la pression de votre réseau est forte, nous savons d'avance quel débit reste disponible, au lieu de l'apprendre à l'équilibrage.

Drain facultatif selon le climat

L'ATMO 150E est livré avec un raccord et un bouchon de drain. Fantech demande le tube de drainage seulement là où il fait habituellement moins de −25 °C dehors et où l'humidité intérieure dépasse 40 % pendant 24 à 96 heures. Sinon, le bouchon ferme le raccord.

Dans la plupart des maisons de Montréal, de Longueuil ou de la Rive-Nord, nous évaluons ces conditions avec vous. Quand le drain n'est pas nécessaire, l'appareil peut aller là où il n'y a pas de drain de plancher.

Efficacité et consommation

Le noyau du VRE est fait d'une membrane polymère très perméable à la vapeur d'eau; il mesure 12 × 12 po sur 10 po de profondeur. Il transfère la chaleur et une partie de l'humidité, et Fantech le dit tolérant au gel et lavable à l'eau.

Selon HVI, l'efficacité de récupération sensible est de 75 % à 64 pcm et à 0 °C, et l'efficacité sensible ajustée de 81 %. À −25 °C, elle reste à 60 % au même débit de 64 pcm, au-dessus du seuil de 54 % de la section 9.32 du Code de construction du Québec pour le Grand Montréal. En climatisation, la fiche donne une efficacité totale de 60 % à 64 pcm.

Au point d'essai de 64 pcm, il consomme 52 W, soit 1,2 pcm/W. En marche continue, cela représente environ 456 kWh par année, à peu près 51 $ au tarif D d'Hydro-Québec (11,142 ¢/kWh).

Le dégivrage démarre à −10 °C et moins : le ventilateur d'alimentation s'arrête et celui d'évacuation passe en haute vitesse, puis l'appareil reprend son fonctionnement normal.

Installation

  • Dimensions : 23,88 × 11,94 × 21,44 po (L × P × H)
  • Poids : 51 lb
  • Raccords : 6 po, ronds, latéraux, avec collets ISF coulissants
  • Alimentation : 120 V
  • Drain : facultatif selon le climat

L'appareil se fixe au mur avec le support ou se suspend au plafond avec des chaînes. Fantech demande 17 po libres devant l'appareil pour retirer le noyau, et 2 3/8 po au-dessus du boîtier électrique. Avec les collets, la largeur hors tout est de 29 1/2 po.

Filtres

Deux filtres électrostatiques lavables MERV 3 de 10 × 11 7/8 po sont fournis, à laver à l'eau tiède savonneuse. En option : MERV 8 (463943) et MERV 13 (463944). Un filtre plus fin ajoute de la pression statique; avec la courbe publiée jusqu'à 0,8 po, nous pouvons en mesurer l'effet d'avance.

Garantie

Fantech garantit le noyau 5 ans, les moteurs des ventilateurs 7 ans et les composants électriques 5 ans. L'appareil est conçu pour un usage résidentiel seulement.

L'ATMO 150E est admissible à l'aide Rénoclimat de 500 $ si l'appareil est homologué à la section III du répertoire HVI (c'est le cas de l'ATMO 150E, numéro HVI 2005030) et si la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux. Nous vous indiquons à quel moment la demander pour ne pas perdre l'aide.

Installation par AirGreen dans le Grand Montréal

Le calcul pièce par pièce de la norme CSA F326 fixe le débit dont votre maison a besoin. Nous estimons ensuite la pression statique de votre réseau de conduits et nous lisons, sur la courbe de l'ATMO 150E, le débit qu'il fournira réellement.

À la mise en service, nous équilibrons l'appareil au manomètre, jusqu'au débit calculé. Nous installons à Montréal, Laval, Longueuil, sur la Rive-Nord et la Rive-Sud.

Pour une soumission gratuite, composez le 514 316-2973 ou écrivez à sales@airgreen.ca.