Fantech ERV FIT 80E-D-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$40.99
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 80E-D-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 21 7/8 in, versus 21 5/8 in for the FIT 80E-HC.
-HCHard-connect version shipped without a cord
The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 80E-D-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005306Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.
42 WMeasured at the airflow it actually runs at
Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 30 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005306) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 93 cfm
- Net airflow at 0.4 in. w.g.
- 78 cfm
- SRE at 0 °C (42 cfm)
- 70%
- SRE at −25 °C (53 cfm)
- 55%
- ASE at 0 °C
- 75%
- Power draw
- 42 W
- Efficacy
- 1.0 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
- Dimensions (L × D × H)
- 20.63 × 18.19 × 10.06 in
- Weight
- 30 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005306
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005306). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
For a forced-air unit where the code requires fixed wiring
The Fantech FIT 80E-D-HC is meant for job sites that combine two requirements: an air exchanger connected to the furnace return, and a permanent electrical supply, with no cord or plug. The motorized damper (-D) protects the system against untreated outdoor air; the -HC version arrives without a cord, ready to be wired to the circuit.
It is an energy recovery ventilator (ERV) from the FIT 80 series: net airflow of 78 cfm at 0.4 in., a range of 20 to 78 cfm, 4 in. side connections and a weight of only 30 lb. Its 10.06 in. thick cabinet fits on the ceiling of a closet or a mechanical room.
The damper, on the outdoor air side
Fantech explains it in its manual: when the unit is off, no stale air passes through it, but the furnace blower keeps drawing outdoor air through its duct. This cold air then enters the house without being tempered, and the load on the system increases. The damper of the FIT 80E-D-HC closes when the unit stops and cuts off that path. With it, the width goes from 21 5/8 in. to 21 7/8 in.
The fixed connection
The supply wires enter the electrical box through a 3/8 in. cable clamp and connect to the unit's wires and ground screw. Allow 2 3/8 in. of free space above the box. On the low-voltage side, the terminal block takes the wall control, the bathroom timers and the furnace interlock relay (NO, C, NC).
Measured efficiency
The HVI data: 70% sensible recovery efficiency at 0 °C and 42 cfm, 75% adjusted, 55% at −25 °C and 53 cfm. That last figure meets the 54% threshold of section 9.32 of the Code that applies to Greater Montreal. In summer, at 35 °C, total recovery is 50%. Power consumption: 42 W at the test airflow, 52 W at high speed, for a maximum current of 0.6 A.
Dimensions and clearances
- 20.63 × 18.19 × 10.06 in.
- 8 1/2 in. in front of the door to remove the core.
- No drain to connect.
- Mounting bracket included, for ceiling or wall.
Fantech recommends placing the unit in a mechanical room, near an exterior wall, in a space that stays above 10 °C, and away from the main rooms of the house.
Balancing with the furnace running
An ERV tied to the return plenum must be balanced under real conditions. Fantech requires doing the procedure with the blower running and the unit at high speed. Airflow is measured first on the stale air side, then on the fresh air side, with a programmable Fantech touchscreen wall control and a manometer. Each press on the control changes a fan's speed by 1%. The low and medium speeds follow the maximum speed setting. We then record the measured pressure and both airflows on the commissioning report.
Air intake and stale air outlet
Fresh air is taken at least 18 in. above the ground or the accumulated snow, 3 ft or more from a wall corner, and away from a dryer vent or the exhaust of a high-efficiency furnace. The stale air outlet follows the same distances and must avoid a meter or a sidewalk, where frost could block the way. Neither one goes in a garage.
Filtration
Filters supplied: two washable MERV 3 electrostatic filters, 9 1/2 × 8 1/2 in. size. Optional filters: MERV 8 (484397) or MERV 13 (484396). The membrane core can also be washed with water.
Manufacturer's warranty
Fantech: 7 years on the motors; 5 years on the core, the electrical components and the damper motor. Replacement parts are found on the Fantech portal, accessible through the code printed on the nameplate.
AirGreen, from design to commissioning
For a project in Montreal, Laval, Longueuil, the North Shore or the South Shore, we establish the required airflows room by room according to the CSA F326 standard. We coordinate the circuit with your electrician, connect the ERV to the return plenum and balance supply and exhaust with a manometer, up to the calculated airflow.
The FIT 80E-D-HC is listed in Section III of the HVI directory under No. 2005306, which makes its airflows and efficiencies verifiable by anyone. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or an ERV; only files already opened under the program's transition rules remain eligible.
Free quote: 514 316-2973, sales@airgreen.ca.