Échangeur d'Air Fantech ERV HERO 100E | Montréal, Laval, Longueuil, Rive Sud et Rive Nord

In stock
SKU: HERO 100E
102 cfm net1,200 to 1,900 sq ft60% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 102 cfm net, enough to ventilate 1,200 to 1,900 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 102 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
60%
At −25 °CCode: 54% minimum
82%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 12 cfm
0.2 in · test bench114 cfm
0.4 in · with ducts102 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 68 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

MERV 8Optional MERV 8 filter, but no MERV 13

The HERO 100E ships with two washable MERV 3 electrostatic filters. Fantech offers optional MERV 8 filters (428525), which are disposable and not washable, but no MERV 13 for this size, unlike the HERO models with 6 in connections.

12 inCore removal: 12 in free in front of the door

The HERO 100E's core and filters come out through the front door, held by two latches under the unit. Fantech calls for 12 in (305 mm) in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.

60%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 68 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005335Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−12 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 114 to 102 cfm. Most spec sheets show only the first number, precisely because it looks better.

42 WMeasured at the airflow it actually runs at

Its 82% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

5 inWhat it needs on site

5 in ducts, top connection. It weighs 47 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005335. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

5 in ductsCollar diameter
Top connectionTop ports
47 lbUnit weight
23.25 × 11.5 × 24.25 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
114 cfm
Net airflow at 0.4 in. w.g.
102 cfm
SRE at 0 °C (42 cfm)
82%
SRE at −25 °C (68 cfm)
60%
ASE at 0 °C
88%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Top ports
Duct collars
5 in
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable electrostatic MERV 3 panel filters; optional MERV 8 (428525), not washable (no MERV 13)
Dimensions (L × D × H)
23.25 × 11.5 × 24.25 in
Weight
47 lb
Power supply
120 V
HVI certification (Section III)
2005335
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005335). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Un VRE compact pour les condos et les petites maisons

Le Fantech HERO 100E est le plus petit ventilateur récupérateur d'énergie (VRE) de la série HERO. Son débit net est de 102 pcm à 0,4 po de pression statique, et de 114 pcm à 0,2 po. C'est un format pensé pour un condo, un jumelé ou une petite maison, où l'échangeur d'air doit entrer dans un placard technique ou un coin de sous-sol.

Comme tout VRE, il récupère la chaleur de l'air vicié qu'il évacue, mais aussi une partie de son humidité. L'hiver, l'air frais entre moins sec. L'été, une partie de l'humidité extérieure reste dehors. Dans un petit logement bien scellé, où l'air devient vite trop sec en janvier, c'est ce qui fait la différence avec un VRC.

Raccords de 5 po et aucun drain à prévoir

Le HERO 100E se raccorde par le dessus, avec des collets ronds de 5 po en métal munis de joints caoutchoutés. Le raccordement vertical garde l'appareil mince : 11,5 po de profondeur seulement. Les conduits partent directement vers le plafond.

Comme c'est un VRE, il n'a pas besoin de drain. Le manuel de Fantech réserve la ligne de drainage aux modèles VRC. Pas de tube à raccorder, pas de pente à respecter vers un drain de plancher. Dans un condo sans drain à proximité, c'est souvent ce qui rend l'installation possible à l'endroit voulu.

Filtration : MERV 8 en option, pas de MERV 13

L'appareil est livré avec deux filtres électrostatiques lavables MERV 3. Fantech offre en option des filtres MERV 8 (428525), jetables et non lavables. Il n'existe toutefois aucun filtre MERV 13 pour ce format, contrairement aux HERO à raccords de 6 po.

Si vous visez une filtration MERV 13, pour des allergies par exemple, il faut plutôt regarder le HERO 140E ou le HERO 160E-EC. Nous vous le dirons dès la visite : mieux vaut le savoir avant l'achat qu'au premier changement de filtres.

Efficacité et consommation

Selon les données HVI, l'efficacité de récupération sensible du HERO 100E est de 82 % à 42 pcm et à 0 °C, et son efficacité sensible ajustée atteint 88 %. Par grand froid, elle reste à 60 % à −25 °C (mesurée à 68 pcm). C'est au-dessus du seuil de 54 % à −25 °C de la section 9.32 du Code de construction du Québec pour le Grand Montréal. En climatisation, le guide de Fantech lui donne une efficacité totale de 70 %.

Au point d'essai de 42 pcm, l'appareil consomme 42 W, soit 1,0 pcm/W. En marche continue toute l'année, cela donne environ 368 kWh, à peu près 41 $ d'électricité au tarif D d'Hydro-Québec (11,142 ¢/kWh).

Le dégivrage se fait par recirculation. Quand il s'active, un volet interne s'ouvre du côté intérieur et l'air de la maison passe dans le noyau pour le dégager. L'appareil n'aspire pas d'air extérieur pendant ce temps et n'évacue pas d'air vers l'extérieur.

Installation : dimensions, poids et dégagements

  • Dimensions : 23,25 × 11,5 × 24,25 po (L × P × H)
  • Poids : 47 lb
  • Raccords : 5 po, ronds, sur le dessus
  • Alimentation : 120 V
  • Drain : non requis

Le HERO 100E se fixe au mur sur le support long fourni, ou se suspend aux solives avec les quatre chaînes et ressorts inclus dans la boîte. Fantech demande 12 po libres devant la porte pour retirer le noyau, et 2 3/8 po au-dessus du boîtier électrique pour le câblage. Pour un fonctionnement silencieux, le manuel recommande des conduits courts, peu de coudes, des coudes à 45° plutôt qu'à 90° et des raccords en Y plutôt qu'en T.

Entretien

Le noyau et les filtres sortent par la porte avant, retenue par deux loquets au bas de l'appareil. Les filtres MERV 3 se lavent à l'eau tiède savonneuse. Si vous passez au MERV 8, ces filtres se remplacent : ils ne se lavent pas. Nous vous montrons le geste à la mise en service, il prend quelques minutes.

Garantie et aide Rénoclimat

Fantech garantit le noyau 5 ans, les moteurs des ventilateurs 7 ans et les composants électriques 5 ans. L'appareil est conçu pour un usage résidentiel seulement.

Le HERO 100E est admissible à l'aide Rénoclimat de 500 $ si l'appareil est homologué à la section III du répertoire HVI (c'est le cas du HERO 100E, numéro HVI 2005335) et si la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux. Nous vous indiquons à quel moment la demander pour ne pas perdre l'aide.

Installation par AirGreen dans le Grand Montréal

Avant de proposer un HERO 100E, nous faisons le calcul de ventilation pièce par pièce selon la norme CSA F326. Ce calcul dit si 102 pcm suffisent pour votre logement. Dans un grand condo avec trois chambres, il se peut que non, et nous vous proposerons alors un modèle plus grand plutôt qu'un appareil qui tourne toujours au maximum.

Une fois l'appareil posé, nous équilibrons l'alimentation et l'évacuation au débit calculé, au manomètre. Nous installons à Montréal, à Laval, à Longueuil, sur la Rive-Nord et sur la Rive-Sud.

Pour une soumission gratuite, appelez-nous au 514 316-2973 ou écrivez à sales@airgreen.ca.