Fantech ERV HERO 120E-EC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 112 cfm net, enough to ventilate 1,300 to 2,100 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 112 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$20.50
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 63% at 70 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 21 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
ECMEC motors: 2.1 cfm/W versus 1.2
The HERO 120E-EC uses the HERO 100E cabinet with electronically commutated motors. Fantech's guide gives it 2.1 cfm/W fan efficacy at 0 °C, versus 1.2 for the HERO 100E, and 40 to 112 cfm at 0.4 in instead of 40 to 102.
MERV 8Optional MERV 8 filter, but no MERV 13
The HERO 120E-EC ships with two washable MERV 3 electrostatic filters. Fantech offers optional MERV 8 filters (428525), which are disposable and not washable, but no MERV 13 for this size, unlike the HERO models with 6 in connections.
63%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 70 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005477Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−11 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 123 to 112 cfm.
21 WMeasured at the airflow it actually runs at
Its 85% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 21 W, or about 184 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, top connection. It weighs 50 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005477) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 123 cfm
- Net airflow at 0.4 in. w.g.
- 112 cfm
- SRE at 0 °C (42 cfm)
- 85%
- SRE at −25 °C (70 cfm)
- 63%
- ASE at 0 °C
- 88%
- Power draw
- 21 W
- Efficacy
- 2.0 cfm/W
- Type
- ERV
- Connection
- Top ports
- Duct collars
- 5 in
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable electrostatic MERV 3 panel filters; optional MERV 8 (428525), not washable (no MERV 13)
- Dimensions (L × D × H)
- 23.25 × 11.5 × 24.25 in
- Weight
- 50 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005477
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005477). Annual consumption calculated at 21 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The HERO 100E cabinet, with EC motors
The Fantech HERO 120E-EC is the same size as the HERO 100E. What changes is inside: two electronically commutated motors (EC motors) instead of conventional motors. This energy recovery ventilator (ERV) delivers a net airflow of 112 cfm at 0.4 in., and 123 cfm at 0.2 in.
It is aimed at condo or small-home owners who want a compact air exchanger and plan to run it continuously, as it should be run. Over several years, it is the power consumption that makes the difference, not the purchase price.
What the EC motors change
Fantech's selection guide gives the HERO 120E-EC a fan efficiency of 2.1 cfm/W at 0 °C, versus 1.2 for the HERO 100E. The airflow range goes up too: from 40 to 112 cfm at 0.4 in., instead of 40 to 102.
HVI testing confirms it. At the same 42 cfm test point, the HERO 120E-EC draws 21 W, or 2.0 cfm/W. The HERO 100E, in the same cabinet, draws 42. Running continuously, that comes to about 184 kWh per year for the 120E-EC, roughly $21 of electricity at Hydro-Québec Rate D (11.142¢/kWh), versus about $41 for the 100E. The gap repeats every year of the unit's life.
Efficiency in winter and in summer
According to HVI, the sensible recovery efficiency is 85% at 42 cfm and 0 °C, and the adjusted sensible efficiency is 88%. At −25 °C, it is still 63% (measured at 70 cfm), above the 54% threshold in section 9.32 of the Québec Construction Code for Greater Montreal. In cooling mode, Fantech publishes a total efficiency of 80%, the highest of the HERO models in its guide.
An ERV transfers heat and part of the moisture. In winter, the incoming air is less dry. In summer, the air conditioner has less moisture to remove. In a recent, very airtight home, where the dry air of January makes itself felt, it is the best-suited choice.
Defrost works by recirculation: an internal damper opens on the indoor side and house air clears the core, without drawing in outdoor air during the cycle.
Filters: what you need to know
The unit comes with two washable electrostatic MERV 3 filters. Fantech offers MERV 8 filters (428525) as an option, which are disposable and not washable. There is no MERV 13 for this format, unlike the HERO models with 6 in. connections. If fine filtration is a priority, the HERO 160E-EC, which also has EC motors, accepts a MERV 13 filter.
Installation
- Dimensions: 23.25 × 11.5 × 24.25 in. (L × D × H)
- Weight: 50 lb
- Connections: 5 in., round, on top (vertical connection)
- Power supply: 120 V
- Drain: not required
Like the HERO 100E, it mounts on the wall on the supplied bracket or hangs with the included chains and springs. No drain is needed: Fantech reserves the drain line for HRVs. Allow 12 in. of free space in front of the door to remove the core and 2 3/8 in. above the electrical box. Ducts should stay short, with as few elbows as possible.
Fantech recommends a fully dedicated installation, with its own ducts, to reduce power consumption. If the unit is connected to the furnace, a variable-speed EC motor blower keeps costs down. We look at your existing system before choosing.
Maintenance and warranty
The core and filters come out through the front door, held by two latches. The MERV 3 filters wash in warm, soapy water; the MERV 8 filters are replaced.
Fantech warrants the core for 5 years, the motors for 7 years and the electrical components for 5 years. Residential use only.
The HERO 120E-EC is certified in Section III of the HVI directory (number 2005477): its airflows and efficiencies are published and anyone can check them. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already opened under the program's transition rules.
Installation by AirGreen in Greater Montreal
We start with the ventilation calculation for your home, room by room, under the CSA F326 standard. If the need exceeds what 112 cfm can deliver, we tell you and propose a larger model.
At start-up, we set supply and exhaust with a manometer, to the calculated airflow. An unbalanced unit pressurizes or depressurizes the house, and it is a common mistake. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.