Fantech ERV FIT 80E Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 80E
78 cfm net800 to 1,400 sq ft55% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
55%
At −25 °CCode: 54% minimum
70%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench93 cfm
0.4 in · with ducts78 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

8.5 inCore comes out with 8 1/2 in of clearance

Core, filters, fans and electronic panel are reached through the door, held by two latches under the unit. Fantech calls for 8 1/2 in (216 mm) free in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.

10 inWashable 10 × 10 in membrane core

The energy recovery core measures 10 × 10 in with an 8 1/8 in depth. Its polymer membrane, highly permeable to water vapour, is freeze tolerant, water washable and resistant to mold and bacteria, per Fantech's sheet.

55%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005299Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.

42 WMeasured at the airflow it actually runs at

Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

4 inWhat it needs on site

4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005299) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

4 in ductsCollar diameter
Side connectionSide ports
29 lbUnit weight
20.63 × 18.19 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
93 cfm
Net airflow at 0.4 in. w.g.
78 cfm
SRE at 0 °C (42 cfm)
70%
SRE at −25 °C (53 cfm)
55%
ASE at 0 °C
75%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Side ports
Duct collars
4 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
Dimensions (L × D × H)
20.63 × 18.19 × 10.06 in
Weight
29 lb
Power supply
120 V
HVI certification (Section III)
2005299
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005299). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Fantech FIT 80EYou are here800 to 1,400 sq ft78 cfm
Fantech HERO 100ELarger1,200 to 1,900 sq ft102 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

A slim ERV for condos and small dwellings

The Fantech FIT 80E is an energy recovery ventilator (ERV) designed for multi-unit housing: condo, apartment, plex unit. Its cabinet is only 10.06 in. thick and mounts on the ceiling or wall with the supplied bracket. It delivers an HVI-certified net airflow of 78 cfm at 0.4 in. of static pressure, and 93 cfm at 0.2 in.

This is the base version of the 80 format: connections to the dwelling on the right side, power cord supplied, no motorized damper. We mainly offer it for a fully dedicated installation, where the unit has its own duct system, with no connection to a forced-air system. Fantech recommends exactly this method with electric baseboards, hydronic heating, radiant floors or a wall-mounted heat pump, heating types that are very common in Greater Montreal condos.

Heat and moisture recovery

Like any ERV, the FIT 80E transfers heat and part of the moisture between the outgoing stale air and the incoming fresh air. Its sensible recovery efficiency reaches 70% at 0 °C, measured at 42 cfm, and 75% as an adjusted value. At −25 °C, it is still 55% at 53 cfm. That result exceeds the 54% threshold required at that temperature by section 9.32 of the Construction Code for Greater Montreal: by a small margin, but it does exceed it.

In summer, Fantech's sheet gives a total recovery efficiency of 50% at 35 °C and 42 cfm. Part of the outdoor humidity stays outside, which lightens the load on the air conditioner.

The membrane core

The core measures 10 × 10 in. with a depth of 8 1/8 in. Its polymer membrane lets water vapour through, tolerates freezing, can be washed with water and resists mould and bacteria, according to the manufacturer's sheet. It slides out of the unit with only 8 1/2 in. of clearance in front of the door. So the unit can go in a narrow closet without making maintenance a chore.

Power consumption

At 42 cfm, the two fans draw 42 W, or 1.0 cfm per watt. At 81 cfm, the sheet lists 52 W. The annual estimate shown in the spec sheet above is 368 kWh. The fans are factory-balanced, have backward-curved blades and run on sealed ball bearings, lubricated for life.

Installation and connections

  • Dimensions: 20.63 × 18.19 × 10.06 in.; weight: 29 lb with the core.
  • Four 4 in. round connections on the sides (side connection), with a rubber gasket.
  • No drain required: no trap to plan for.
  • 2 3/8 in. of clearance above the electrical box for wiring.
  • 120 V power supply by cord.

Defrost works by stopping the supply fan. At −10 °C and below, the unit shuts off the fresh air intake, runs the exhaust at high speed, then returns to normal operation.

Filter maintenance

Two washable MERV 3 electrostatic filters, 9 1/2 × 8 1/2 in., are supplied. Fantech offers MERV 8 (484397) and MERV 13 (484396) filters as options. The manufacturer's schedule calls for inspecting and washing the filters every three months, and checking the core every six months.

Where to install it

Fantech gives a few simple rules for choosing the location. The unit must be near a 120 V outlet, near the exterior wall the hoods will go through, and in a space that stays above 10 °C at all times. It is best kept away from living areas: a mechanical room, a storage closet or a laundry room ceiling all work well. Access must stay clear for maintenance.

Supply grilles go in the bedrooms and the living room; exhaust grilles, in the bathroom, the kitchen or the laundry room. The manufacturer places them high on the wall or on the ceiling. It also prohibits connecting an appliance, such as a clothes dryer, to the ERV ductwork: lint and grease would clog the unit and the warranty would be void.

Warranty

Fantech warrants the core for 5 years, the fan motors for 7 years and the electrical components for 5 years. The FIT 80E is compatible with all Fantech wall controls, from the bathroom timer to the ECO-Touch Auto IAQ control.

Installation by AirGreen in Greater Montreal

We install the FIT 80E in Montreal, Laval, Longueuil, the North Shore and the South Shore. Before recommending it, we calculate the ventilation requirement room by room according to the CSA F326 standard, then check that 78 cfm is enough for your home. After installation, we balance supply and exhaust to the calculated airflow.

In the HVI directory, the FIT 80E is certified in Section III (No. 2005299): anyone can check its airflows and efficiencies there. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already opened under the program's transition rules.

For a free quote, call us at 514 316-2973 or write to sales@airgreen.ca.