Échangeur d'Air Fantech ERV FIT 80E-D-M-HC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord
Is it the right size for your home?
It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$40.99
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 80E-D-M-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 21 7/8 in, versus 21 5/8 in for the FIT 80E-M-HC.
-M-HCMirrored and cordless in one unit
The FIT 80E-D-M-HC combines two options of the FIT 80E-D: the dwelling-side ports move to the left (-M) and the unit ships with no cord for permanent wiring to the circuit (-HC). The combination suits mirror-image floor plans where code requires a fixed connection.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005307Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm. Most spec sheets show only the first number, precisely because it looks better.
42 WMeasured at the airflow it actually runs at
Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 30 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat: $500 to install or replace an HRV or ERV
First condition met: HVI Section III certified, No. 2005307. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 93 cfm
- Net airflow at 0.4 in. w.g.
- 78 cfm
- SRE at 0 °C (42 cfm)
- 70%
- SRE at −25 °C (53 cfm)
- 55%
- ASE at 0 °C
- 75%
- Power draw
- 42 W
- Efficacy
- 1.0 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
- Dimensions (L × D × H)
- 20.63 × 18.19 × 10.06 in
- Weight
- 30 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005307
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005307). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Le FIT 80 avec toutes ses options
Le nom du Fantech FIT 80E-D-M-HC se lit comme une fiche technique. « 80 » indique un débit d'environ 80 pcm à 0,4 po; « E », la récupération d'énergie; « D », le volet motorisé; « M », la configuration miroir; « HC », le raccordement électrique permanent. Cet échangeur d'air réunit donc les trois options offertes sur le format 80.
Il vise un cas précis : un logement en plan inversé, relié à une fournaise ou à un appareil de traitement d'air, dans un projet où le code impose un branchement fixe. Son débit net homologué est de 78 pcm à 0,4 po.
Les trois options, une par une
Le volet motorisé
Il se ferme lorsque le VRE est arrêté et empêche la soufflerie de la fournaise d'aspirer de l'air extérieur non traité. Fantech le recommande dès que l'appareil est raccordé au retour du système à air pulsé.
La configuration miroir
L'alimentation et le retour d'air du logement se raccordent à gauche, alors que la version standard les place à droite.
Le raccordement permanent
L'appareil est livré sans cordon; l'alimentation entre par un serre-câble de 3/8 po dans le boîtier électrique.
Les trois options ne sont pas toujours nécessaires
Nous le vérifions avant de commander. Le format 80 existe en huit combinaisons, du FIT 80E de base à ce modèle complet. Sans fournaise, le volet ne sert à rien et un FIT 80E-M-HC fait le même travail. Si le code accepte un appareil sur prise, le FIT 80E-D-M suffit. Le FIT 80E-D-M-HC devient le bon choix quand les trois conditions sont réunies : plan inversé, raccordement au retour d'une fournaise et câblage fixe exigé. Dans un immeuble en miroir, les unités d'orientation standard reçoivent alors le FIT 80E-D-HC.
Rendement du format 80
Selon le répertoire HVI, ce ventilateur récupérateur d'énergie récupère 70 % de la chaleur sensible à 0 °C (42 pcm), 75 % en valeur ajustée. Par grand froid, à −25 °C et 53 pcm, le taux est de 55 %; c'est plus que les 54 % demandés à la section 9.32 du Code pour le Grand Montréal. En été, sa récupération totale est de 50 % à 35 °C. Il consomme 42 W au débit d'essai.
Encombrement
- 20,63 × 18,19 × 10,06 po; largeur hors tout avec le volet : 21 7/8 po.
- 30 lb, pour un boîtier de seulement 10,06 po d'épaisseur.
- Montage au plafond ou au mur, support inclus; porte à deux loquets pour l'entretien.
- Quatre raccords latéraux ronds de 4 po.
- Aucun drain.
- Dégagements : 8 1/2 po devant la porte, 2 3/8 po au-dessus du boîtier électrique.
Filtres et noyau
Deux filtres électrostatiques MERV 3 de 9 1/2 × 8 1/2 po sont compris; MERV 8 (484397) et MERV 13 (484396) en option. Le noyau à membrane de 10 × 10 po se rince à l'eau claire, puis sèche deux à trois heures sur un tapis, plaques à la verticale. À la remise en place, la flèche doit pointer vers les moteurs.
Démarrage et réglage
Au démarrage, l'appareil tourne dix secondes en évacuation seule, puis passe au mode choisi. L'équilibrage se fait ensuite avec la soufflerie de la fournaise en marche et le VRE en haute vitesse. La soufflerie est asservie par le relais de l'appareil : contact NO-C quand il ventile, NC-C en attente. En dégivrage, le ventilateur d'alimentation s'arrête et seul l'air vicié circule, le temps de dégager le noyau.
Une commande pour les occupants exigeants
Dans un logement haut de gamme, la commande ECO-Touch Auto IAQ est la plus complète de Fantech. Son écran tactile rétroéclairé permet de fixer une plage d'humidité et un mode de ventilation pour le jour et la nuit. Elle affiche un rappel d'entretien et des codes d'erreur, garde ses réglages après une panne et accepte la minuterie sans fil RTS-W dans les salles de bain.
Garantie Fantech
Moteurs : 7 ans. Noyau, composants électriques et moteur du volet : 5 ans.
Installation par AirGreen
Nous installons ce modèle à Montréal, à Laval, à Longueuil, sur la Rive-Nord et sur la Rive-Sud. Le calcul de ventilation par pièce selon CSA F326 confirme d'abord qu'un format 80 suffit. Nous coordonnons le branchement avec l'électricien, nous asservissons la fournaise par le relais de l'appareil et nous équilibrons les débits une fois la soufflerie en marche.
Inscrit sous le no 2005307, le FIT 80E-D-M-HC est homologué à la section III du répertoire HVI. Il peut rendre un projet admissible à l'aide Rénoclimat de 500 $, à condition que la cote ÉnerGuide s'améliore entre les deux évaluations et que l'évaluation soit faite avant le début des travaux.
Soumission gratuite : 514 316-2973 ou sales@airgreen.ca.