Fantech ERV FIT 80E-D-M-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$40.99
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 80E-D-M-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 21 7/8 in, versus 21 5/8 in for the FIT 80E-M-HC.
-M-HCMirrored and cordless in one unit
The FIT 80E-D-M-HC combines two options of the FIT 80E-D: the dwelling-side ports move to the left (-M) and the unit ships with no cord for permanent wiring to the circuit (-HC). The combination suits mirror-image floor plans where code requires a fixed connection.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005307Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.
42 WMeasured at the airflow it actually runs at
Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 30 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005307) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 93 cfm
- Net airflow at 0.4 in. w.g.
- 78 cfm
- SRE at 0 °C (42 cfm)
- 70%
- SRE at −25 °C (53 cfm)
- 55%
- ASE at 0 °C
- 75%
- Power draw
- 42 W
- Efficacy
- 1.0 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
- Dimensions (L × D × H)
- 20.63 × 18.19 × 10.06 in
- Weight
- 30 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005307
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005307). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The FIT 80 with all its options
The name of the Fantech FIT 80E-D-M-HC reads like a spec sheet. “80” indicates an airflow of about 80 cfm at 0.4 in.; “E,” energy recovery; “D,” the motorized damper; “M,” the mirror configuration; “HC,” the permanent electrical connection. This air exchanger therefore combines the three options offered on the 80 format.
It targets a specific case: a reversed-plan dwelling, connected to a furnace or an air handler, in a project where the code requires a fixed connection. Its HVI-certified net airflow is 78 cfm at 0.4 in.
The three options, one by one
The motorized damper
It closes when the ERV is off and prevents the furnace blower from drawing in untreated outdoor air. Fantech recommends it as soon as the unit is connected to the return of the forced-air system.
The mirror configuration
The dwelling's supply and return air connect on the left, whereas the standard version puts them on the right.
The permanent connection
The unit ships without a cord; the power supply enters the electrical box through a 3/8 in. cable clamp.
The three options are not always needed
We check this before ordering. The 80 format comes in eight combinations, from the base FIT 80E to this complete model. Without a furnace, the damper serves no purpose and a FIT 80E-M-HC does the same job. If the code accepts a plug-in unit, the FIT 80E-D-M is enough. The FIT 80E-D-M-HC becomes the right choice when all three conditions are met: a reversed plan, a connection to a furnace return and required fixed wiring. In a mirrored building, the units with standard orientation then get the FIT 80E-D-HC.
Performance of the 80 format
According to the HVI directory, this energy recovery ventilator recovers 70% of the sensible heat at 0 °C (42 cfm), 75% as an adjusted value. In severe cold, at −25 °C and 53 cfm, the rate is 55%; that is more than the 54% required by section 9.32 of the Code for Greater Montreal. In summer, its total recovery is 50% at 35 °C. It draws 42 W at the test airflow.
Footprint
- 20.63 × 18.19 × 10.06 in.; overall width with the damper: 21 7/8 in.
- 30 lb, for a cabinet only 10.06 in. thick.
- Ceiling or wall mounting, bracket included; two-latch door for maintenance.
- Four 4 in. round side connections.
- No drain.
- Clearances: 8 1/2 in. in front of the door, 2 3/8 in. above the electrical box.
Filters and core
Two MERV 3 electrostatic filters, 9 1/2 × 8 1/2 in., are included; MERV 8 (484397) and MERV 13 (484396) are optional. The 10 × 10 in. membrane core is rinsed with clean water, then dries for two to three hours on a mat, with the plates vertical. When it goes back in, the arrow must point toward the motors.
Start-up and adjustment
At start-up, the unit runs for ten seconds in exhaust only, then switches to the selected mode. Balancing is then done with the furnace blower running and the ERV at high speed. The blower is interlocked through the unit's relay: NO-C contact when it ventilates, NC-C in standby. During defrost, the supply fan stops and only stale air moves, long enough to clear the core.
A control for demanding occupants
In a high-end dwelling, the ECO-Touch Auto IAQ control is Fantech's most complete. Its backlit touchscreen lets you set a humidity range and a ventilation mode for day and night. It displays a maintenance reminder and error codes, keeps its settings after a power outage and accepts the RTS-W wireless timer in the bathrooms.
Fantech warranty
Motors: 7 years. Core, electrical components and damper motor: 5 years.
Installation by AirGreen
We install this model in Montreal, Laval, Longueuil, the North Shore and the South Shore. The room-by-room ventilation calculation according to CSA F326 first confirms that an 80 format is enough. We coordinate the connection with the electrician, interlock the furnace through the unit's relay and balance the airflows once the blower is running.
The FIT 80E-D-M-HC is certified in Section III of the HVI directory (No. 2005307): its airflows and efficiencies are published and anyone can check them. Note that since October 1, 2026, installing an HRV or an ERV is no longer eligible for Rénoclimat assistance, except for files opened before that date under the transition rules.
Free quote: 514 316-2973 or sales@airgreen.ca.