Fantech ERV FIT 80E-D-M Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$40.99
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 80E-D-M has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 21 7/8 in, versus 21 5/8 in for the FIT 80E-M.
-MMirrored version: dwelling-side ports on the left
On the FIT 80E-D, the dwelling's supply and return air connect on the right-hand side; on the FIT 80E-D-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005305Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.
42 WMeasured at the airflow it actually runs at
Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 30 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005305) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 93 cfm
- Net airflow at 0.4 in. w.g.
- 78 cfm
- SRE at 0 °C (42 cfm)
- 70%
- SRE at −25 °C (53 cfm)
- 55%
- ASE at 0 °C
- 75%
- Power draw
- 42 W
- Efficacy
- 1.0 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
- Dimensions (L × D × H)
- 20.63 × 18.19 × 10.06 in
- Weight
- 30 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005305
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005305). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A motorized damper and left-side connections in a single unit
The Fantech FIT 80E-D-M combines two options of the FIT series. The “D” adds a motorized damper on the outdoor air; the “M” puts the dwelling's supply and return air on the left side rather than the right. It is the logical choice for a reversed-plan dwelling whose ERV will be connected to a furnace return.
This energy recovery ventilator keeps the 80 format: 78 cfm of net airflow at 0.4 in., 93 cfm at 0.2 in., 4 in. connections and a 10.06 in. thick cabinet that fits on the ceiling of a storage room.
What the damper does
When the unit is off, the furnace blower keeps drawing air. Without a damper, it would pull cold, untreated outdoor air through the supply duct, which adds to the heating load. The built-in damper of the FIT 80E-D-M blocks that path, as Fantech recommends for any installation tied to the forced-air system. It brings the width to 21 7/8 in., instead of 21 5/8 in. for the FIT 80E-M.
What the mirror version does
In a building where the units are built back to back, half of the dwellings have their mechanical room facing the opposite way. With the -M model, the dwelling's ducts arrive on the correct side, and the installation instructions are simply read in reverse. This avoids duct crossovers, which cost airflow and ceiling height.
On the drawings, the difference is easy to spot: the fresh air for the dwelling comes out on the right on a standard unit, and on the left on an -M. We confirm this point against the plan of each unit before placing the order, because a unit facing the wrong way means redoing the duct layout in the ceiling.
Performance
The HVI directory gives a sensible recovery efficiency of 70% at 0 °C (42 cfm) and 75% adjusted. At −25 °C, it is 55% at 53 cfm, above the 54% required by section 9.32 of the Code in Greater Montreal. Power consumption is 42 W at the test airflow; at high speed, Fantech lists 52 W. The airflow range of the 80 format runs from 20 to 78 cfm, at low, medium or high speed.
Installation
- Dimensions: 20.63 × 18.19 × 10.06 in.; weight: 30 lb.
- Side connection, 4 in. round ducts.
- No drain required.
- Furnace blower running continuously, or interlocked through the NO, C and NC terminals.
- Setup to avoid with a multi-zone system or several forced-air systems.
Ducts, installed according to the manual
A compact unit only delivers its airflow if the ducts keep up. Fantech calls for galvanized ducts to the main rooms, branches of at least 4 in. to each room, and a main duct at least as large as the unit's connection. Joints are screwed or sealed, then covered with aluminum tape. On the outdoor side, the insulated flexible duct must be pulled taut, with no twists or kinks, and its insulation must not be compressed. The connections to the unit are secured with a clamp, insulated, then covered with the vapour barrier.
Replacement parts
Fantech offers the fan motor, the damper motor assembly, the control board, the core and the door as replacement parts. To order, the serial number on the nameplate is all you need.
Maintenance
Two washable MERV 3 electrostatic filters, 9 1/2 × 8 1/2 in., are supplied. The MERV 8 (484397) and MERV 13 (484396) versions are ordered separately. Fantech schedules a filter inspection every three months, a core inspection every six months, and an annual cleaning of the inside of the unit and of the exterior hoods.
Warranty
Core 5 years, motors 7 years, electrical components and damper motor 5 years.
Installation by AirGreen in Greater Montreal
In Montreal, Laval, Longueuil, the North Shore and the South Shore, we start from a room-by-room ventilation calculation according to CSA F326. We check the direction of the connections on the plan before ordering, connect the unit to the furnace return, then balance both fans to the calculated airflow, with the blower running.
The FIT 80E-D-M is certified in Section III of the HVI directory (No. 2005305): its airflows and efficiencies are published and anyone can check them. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already opened under the program's transition rules.
For a free quote, dial 514 316-2973 or write to sales@airgreen.ca.