Fantech ERV FIT 80E-D Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 80E-D
78 cfm net800 to 1,400 sq ft55% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
55%
At −25 °CCode: 54% minimum
70%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench93 cfm
0.4 in · with ducts78 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-DBuilt-in motorized outdoor air damper

The -D suffix means the FIT 80E-D has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 21 7/8 in, versus 21 5/8 in for the FIT 80E.

8.5 inCore comes out with 8 1/2 in of clearance

Core, filters, fans and electronic panel are reached through the door, held by two latches under the unit. Fantech calls for 8 1/2 in (216 mm) free in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.

55%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005304Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.

42 WMeasured at the airflow it actually runs at

Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

4 inWhat it needs on site

4 in ducts, side connection. It weighs 30 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005304) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

4 in ductsCollar diameter
Side connectionSide ports
30 lbUnit weight
20.63 × 18.19 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
93 cfm
Net airflow at 0.4 in. w.g.
78 cfm
SRE at 0 °C (42 cfm)
70%
SRE at −25 °C (53 cfm)
55%
ASE at 0 °C
75%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Side ports
Duct collars
4 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
Dimensions (L × D × H)
20.63 × 18.19 × 10.06 in
Weight
30 lb
Power supply
120 V
HVI certification (Section III)
2005304
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005304). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Fantech FIT 80E-DYou are here800 to 1,400 sq ft78 cfm
Fantech HERO 100ELarger1,200 to 1,900 sq ft102 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The FIT 80E with a motorized damper, for a home heated by forced air

When an air exchanger is connected to a furnace return, one detail changes everything: what happens when it is off. The furnace blower keeps drawing air and, without a damper, it pulls untreated outdoor air through the unit. The Fantech FIT 80E-D settles this question with a built-in motorized damper on the outdoor air side.

Otherwise, it is the same compact FIT 80 platform: an energy recovery ventilator 10.06 in. thick, a net airflow of 78 cfm at 0.4 in. (93 cfm at 0.2 in.) and 4 in. round connections. It is aimed at condos, apartments and townhouses equipped with a furnace or an air handler.

Two ways to connect it to the furnace

Fantech describes two setups with a forced-air system. In the partially dedicated installation, fresh air is delivered into the furnace return plenum, which tempers and distributes it, while stale air is drawn from the bathroom, the kitchen or the laundry room. In the simplified installation, known as return-return, supply and exhaust are both tapped into the return plenum. This second method is used mainly in renovations, when the wet rooms already have their own exhaust fans.

In both cases, the manufacturer recommends a unit fitted with a damper. That is precisely what the -D suffix adds. These setups are not suitable, however, for a multi-zone system, or for a house with more than one forced-air system.

Interlocking the furnace

The blower must run when the FIT 80E-D is ventilating. It is either left running continuously, or interlocked with the unit through the relay's NO, C and NC terminals: contact is made between NO and C during ventilation, and between NC and C in standby. We set up this wiring at commissioning.

Performance

The sensible recovery efficiency is 70% at 0 °C (42 cfm), 75% as an adjusted value, and 55% at −25 °C (53 cfm), above the 54% threshold set by section 9.32 of the Code for Greater Montreal. At 35 °C, total recovery reaches 50%. The two fans draw 42 W at the test airflow and 52 W at high speed, over a range of 20 to 78 cfm.

Dimensions and access

  • Cabinet: 20.63 × 18.19 × 10.06 in.; weight: 30 lb.
  • Width with the damper: 21 7/8 in., versus 21 5/8 in. for the FIT 80E without a damper.
  • Side connection, 4 in. ducts; no drain required.
  • 8 1/2 in. clear in front of the door to remove the core, 2 3/8 in. above the electrical box.

The door is held by two latches at the bottom of the unit. The core, filters, fans and electronic board are all reached through this opening.

The exterior hoods

An ERV connected to a furnace still needs two openings in the wall: a fresh air intake and a stale air outlet. Fantech places the intake at least 18 in. above the ground or above the snow line, at least 3 ft from corners, and away from dryer vents, the furnace exhaust, gas meters, garage entrances and garbage bins. A tandem hood, which combines both openings, is allowed where local regulations accept it. The insulated ducts that connect the unit to the hoods must be short and pulled taut.

80E or 80E-D

If your home is heated by baseboards or a radiant floor, the damper serves no purpose and the standard FIT 80E is enough. As soon as a furnace or an air handler is part of the plan, we recommend the -D version.

Filters and warranty

The unit comes with two washable MERV 3 electrostatic filters, 9 1/2 × 8 1/2 in. MERV 8 (484397) or MERV 13 (484396) filters are available as options. Fantech's warranty covers the fan motors for 7 years, and the core and electrical components for 5 years; the damper motor is also covered for 5 years.

Our installation in Montreal, Laval and on both Shores

Before choosing the FIT 80E-D, we calculate the ventilation needs of each room according to the CSA F326 standard and check compatibility with your furnace. Fantech requires balancing the unit with the blower running and the fans at high speed: we measure the airflows and adjust them to the calculated airflow. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.

The FIT 80E-D is certified in Section III of the HVI directory (No. 2005304): its airflows and efficiencies are published and anyone can check them. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or an ERV; only files already opened under the program's transition rules remain eligible.