Échangeur d'Air Fantech ERV FIT 80E-HC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord

In stock
SKU: FIT 80E-HC
78 cfm net800 to 1,400 sq ft55% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
55%
At −25 °CCode: 54% minimum
70%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench93 cfm
0.4 in · with ducts78 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-HCHard-connect version shipped without a cord

The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 80E-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.

10 inWashable 10 × 10 in membrane core

The energy recovery core measures 10 × 10 in with an 8 1/8 in depth. Its polymer membrane, highly permeable to water vapour, is freeze tolerant, water washable and resistant to mold and bacteria, per Fantech's sheet.

55%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005302Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm. Most spec sheets show only the first number, precisely because it looks better.

42 WMeasured at the airflow it actually runs at

Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

4 inWhat it needs on site

4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005302. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

4 in ductsCollar diameter
Side connectionSide ports
29 lbUnit weight
20.63 × 18.19 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
93 cfm
Net airflow at 0.4 in. w.g.
78 cfm
SRE at 0 °C (42 cfm)
70%
SRE at −25 °C (53 cfm)
55%
ASE at 0 °C
75%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Side ports
Duct collars
4 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
Dimensions (L × D × H)
20.63 × 18.19 × 10.06 in
Weight
29 lb
Power supply
120 V
HVI certification (Section III)
2005302
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005302). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Fantech FIT 80E-HCYou are here800 to 1,400 sq ft78 cfm
Fantech HERO 100ELarger1,200 to 1,900 sq ft102 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Un VRE compact sans cordon, pour un branchement permanent

Certains projets n'acceptent pas un appareil branché dans une prise : devis d'ingénieur, exigence d'un inspecteur, construction où tout est câblé en fixe. Le Fantech FIT 80E-HC répond à ce cas. Le suffixe HC, pour « hard connect », désigne une version livrée sans cordon d'alimentation, à relier directement au circuit.

À l'intérieur, rien ne change par rapport au FIT 80E : même ventilateur récupérateur d'énergie (VRE) à noyau à membrane, même boîtier de 10,06 po d'épaisseur, même débit net de 78 pcm à 0,4 po. Les raccords du logement restent du côté droit, et l'appareil n'a pas de volet motorisé.

Comment se fait le raccordement

Selon le manuel Fantech, on retire le couvercle du compartiment électrique, on pose un serre-câble de 3/8 po sur le boîtier, puis on fait entrer les fils d'alimentation. On les relie ensuite aux fils et à la vis de mise à la terre de l'appareil, avant de remettre le couvercle sans pincer les fils. La mise sous tension se fait au panneau électrique. Il faut 2 3/8 po libres au-dessus du boîtier électrique pour travailler.

Nous coordonnons ce branchement avec un électricien pour que le circuit soit prêt au moment de poser l'appareil. Au rapport de mise en service de Fantech, le type de branchement est alors coché comme câblé plutôt que sur prise.

Performance d'hiver et d'été

À 0 °C et 42 pcm, l'efficacité de récupération sensible est de 70 % (75 % ajustée). À −25 °C et 53 pcm, elle descend à 55 %, un point au-dessus du seuil de 54 % de la section 9.32 du Code pour la région de Montréal. En climatisation, à 35 °C, la récupération totale est de 50 % à 42 pcm. La membrane transfère aussi une partie de l'humidité entre les deux flux d'air.

Consommation

La fiche Fantech donne 42 W à 42 pcm et 52 W à 81 pcm. Le courant de fonctionnement est de 0,6 A. Sur une année, l'estimation de la fiche technique ci-dessus est de 368 kWh.

Selon la fiche Fantech, l'appareil fonctionne à plusieurs vitesses et peut être programmé pour ventiler en continu ou par intermittence. Ses deux ventilateurs à pales incurvées vers l'arrière sont équilibrés en usine.

Pose et dimensions

  • 20,63 × 18,19 × 10,06 po, 29 lb.
  • Boîtier en acier galvanisé G90 de calibre 22, isolé de polystyrène expansé haute densité de 3/4 po.
  • Quatre raccords ronds de 4 po, sur les côtés.
  • Aucun drain.
  • Montage au plafond ou au mur avec le support fourni; porte retenue par deux loquets.
  • 8 1/2 po devant la porte pour sortir le noyau.

Commandes et ordre de priorité

Le bornier basse tension accepte les commandes Fantech, et l'appareil traite les signaux dans un ordre précis. L'arrêt à distance (bornes S+ et S-) passe en premier : un contact fermé met l'appareil en attente, par exemple pendant un essai d'étanchéité. Viennent ensuite la minuterie de salle de bain, puis le déshumidistat, qui force la haute vitesse, puis les commandes murales à quatre fils et à deux fils. Le sélecteur de vitesse de l'appareil arrive en dernier. Dans un logement, cette hiérarchie évite qu'une commande en contredise une autre.

Ce qu'il ne faut pas y raccorder

Fantech interdit de brancher une sécheuse, une hotte de cuisinière ou tout autre appareil sur le réseau du VRE : la charpie, la poussière et la graisse l'endommageraient, et la garantie serait annulée. Aucune bouche de reprise ne doit non plus se trouver dans une pièce fermée qui contient un appareil à combustion.

Filtres

Deux filtres électrostatiques MERV 3 lavables (9 1/2 × 8 1/2 po) sont inclus. En option : MERV 8 (484397) et MERV 13 (484396). Examinez-les tous les trois mois, ou plus tôt s'ils sont sales.

Garantie

Sept ans sur les moteurs des ventilateurs; cinq ans sur le noyau et sur les composants électriques.

Installation par AirGreen : Montréal, Laval, Longueuil et les Rives

Nous dimensionnons chaque installation à partir d'un calcul pièce par pièce selon la norme CSA F326, puis nous équilibrons l'alimentation et l'évacuation au débit obtenu, mesures à l'appui. Pour le FIT 80E-HC, nous planifions aussi le circuit avec l'électricien dès le départ. Nous desservons Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud.

Le FIT 80E-HC porte le no 2005302 au répertoire HVI et y est homologué à la section III. Il peut ainsi être admissible à l'aide Rénoclimat de 500 $ si la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux.

Soumission gratuite au 514 316-2973 ou par courriel à sales@airgreen.ca.