Fantech ERV FIT 80E-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 80E-HC
78 cfm net800 to 1,400 sq ft55% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
55%
At −25 °CCode: 54% minimum
70%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench93 cfm
0.4 in · with ducts78 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-HCHard-connect version shipped without a cord

The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 80E-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.

10 inWashable 10 × 10 in membrane core

The energy recovery core measures 10 × 10 in with an 8 1/8 in depth. Its polymer membrane, highly permeable to water vapour, is freeze tolerant, water washable and resistant to mold and bacteria, per Fantech's sheet.

55%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005302Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.

42 WMeasured at the airflow it actually runs at

Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

4 inWhat it needs on site

4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005302) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

4 in ductsCollar diameter
Side connectionSide ports
29 lbUnit weight
20.63 × 18.19 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
93 cfm
Net airflow at 0.4 in. w.g.
78 cfm
SRE at 0 °C (42 cfm)
70%
SRE at −25 °C (53 cfm)
55%
ASE at 0 °C
75%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Side ports
Duct collars
4 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
Dimensions (L × D × H)
20.63 × 18.19 × 10.06 in
Weight
29 lb
Power supply
120 V
HVI certification (Section III)
2005302
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005302). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Fantech FIT 80E-HCYou are here800 to 1,400 sq ft78 cfm
Fantech HERO 100ELarger1,200 to 1,900 sq ft102 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

A compact ERV without a cord, for a permanent connection

Some projects do not accept a unit plugged into an outlet: an engineer's specification, an inspector's requirement, a building where everything is hard-wired. The Fantech FIT 80E-HC answers this case. The HC suffix, for “hard connect,” designates a version shipped without a power cord, to be wired directly to the circuit.

Inside, nothing changes compared with the FIT 80E: the same membrane-core energy recovery ventilator (ERV), the same 10.06 in. thick cabinet, the same net airflow of 78 cfm at 0.4 in. The dwelling connections stay on the right side, and the unit has no motorized damper.

How the connection is made

According to Fantech's manual, you remove the electrical compartment cover, install a 3/8 in. cable clamp on the box, then bring in the supply wires. You then connect them to the unit's wires and ground screw, before putting the cover back without pinching the wires. Power is turned on at the electrical panel. You need 2 3/8 in. of free space above the electrical box to work.

We coordinate this connection with an electrician so that the circuit is ready when the unit is installed. On Fantech's commissioning report, the connection type is then checked as hard-wired rather than plug-in.

Winter and summer performance

At 0 °C and 42 cfm, the sensible recovery efficiency is 70% (75% adjusted). At −25 °C and 53 cfm, it drops to 55%, one point above the 54% threshold of section 9.32 of the Code for the Montreal area. In cooling mode, at 35 °C, total recovery is 50% at 42 cfm. The membrane also transfers part of the moisture between the two airstreams.

Power consumption

Fantech's sheet gives 42 W at 42 cfm and 52 W at 81 cfm. The operating current is 0.6 A. Over a year, the estimate in the spec sheet above is 368 kWh.

According to Fantech's sheet, the unit runs at several speeds and can be programmed to ventilate continuously or intermittently. Its two fans with backward-curved blades are factory-balanced.

Mounting and dimensions

  • 20.63 × 18.19 × 10.06 in., 29 lb.
  • 22-gauge G90 galvanized steel cabinet, insulated with 3/4 in. high-density expanded polystyrene.
  • Four 4 in. round connections, on the sides.
  • No drain.
  • Ceiling or wall mounting with the supplied bracket; door held by two latches.
  • 8 1/2 in. in front of the door to remove the core.

Controls and order of priority

The low-voltage terminal block accepts Fantech controls, and the unit handles the signals in a specific order. Remote shutdown (S+ and S- terminals) comes first: a closed contact puts the unit in standby, for example during an airtightness test. Next come the bathroom timer, then the dehumidistat, which forces high speed, then the four-wire and two-wire wall controls. The unit's speed selector comes last. In a dwelling, this hierarchy keeps one control from contradicting another.

What must not be connected to it

Fantech prohibits connecting a clothes dryer, a range hood or any other appliance to the ERV ductwork: lint, dust and grease would damage it, and the warranty would be void. Nor should any return grille be located in a closed room that contains a combustion appliance.

Filters

Two washable MERV 3 electrostatic filters (9 1/2 × 8 1/2 in.) are included. Optional: MERV 8 (484397) and MERV 13 (484396). Inspect them every three months, or sooner if they are dirty.

Warranty

Seven years on the fan motors; five years on the core and on the electrical components.

Installation by AirGreen: Montreal, Laval, Longueuil and the Shores

We size each installation from a room-by-room calculation according to the CSA F326 standard, then balance supply and exhaust to the resulting airflow, backed by measurements. For the FIT 80E-HC, we also plan the circuit with the electrician from the start. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.

In the HVI directory, the FIT 80E-HC is certified in Section III (No. 2005302): anyone can check its airflows and efficiencies there. Note that since October 1, 2026, installing an HRV or an ERV is no longer eligible for Rénoclimat assistance, except for files opened before that date under the transition rules.

Free quote at 514 316-2973 or by email at sales@airgreen.ca.