Échangeur d'Air Fantech ERV FIT 80E-M-HC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord
Is it the right size for your home?
It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$40.99
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-MMirrored version: dwelling-side ports on the left
On the FIT 80E, the dwelling's supply and return air connect on the right-hand side; on the FIT 80E-M-HC, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
-HCHard-connect version shipped without a cord
The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 80E-M-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005303Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm. Most spec sheets show only the first number, precisely because it looks better.
42 WMeasured at the airflow it actually runs at
Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat: $500 to install or replace an HRV or ERV
First condition met: HVI Section III certified, No. 2005303. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 93 cfm
- Net airflow at 0.4 in. w.g.
- 78 cfm
- SRE at 0 °C (42 cfm)
- 70%
- SRE at −25 °C (53 cfm)
- 55%
- ASE at 0 °C
- 75%
- Power draw
- 42 W
- Efficacy
- 1.0 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
- Dimensions (L × D × H)
- 20.63 × 18.19 × 10.06 in
- Weight
- 29 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005303
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005303). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Pour les condos chauffés aux plinthes, en plan inversé et câblés en fixe
Beaucoup de condos du Grand Montréal n'ont pas de fournaise : ils sont chauffés par plinthes électriques, parfois avec une thermopompe murale. L'échangeur d'air y a son propre réseau de conduits, et un volet motorisé n'a pas de rôle à jouer. Le Fantech FIT 80E-M-HC est conçu pour ce contexte : raccords du logement à gauche (-M) et alimentation électrique permanente, sans cordon (-HC).
Ce ventilateur récupérateur d'énergie (VRE) offre un débit net de 78 pcm à 0,4 po et de 93 pcm à 0,2 po, dans un boîtier de 10,06 po d'épaisseur. Le format 80 convient aux logements dont le calcul de ventilation reste sous ce débit.
L'installation entièrement dédiée
Fantech présente cette méthode comme la meilleure en construction neuve. L'air neuf est distribué aux chambres et aux pièces principales, et l'air vicié est repris dans la salle de bain, la cuisine ou la salle de lavage, sans passer par un système à air pulsé. Le fabricant la suggère avec les plinthes électriques, le chauffage hydronique, le plancher radiant et la thermopompe murale. Les grilles d'alimentation se placent haut sur le mur ou au plafond, avec des diffuseurs qui répartissent l'air sans courant désagréable.
Deux options, deux raisons
La version miroir sert les immeubles où la moitié des unités est construite à l'envers de l'autre : les raccords arrivent du côté gauche, et le plan de conduits reste simple. La version sans cordon répond aux codes et aux devis qui exigent un raccordement fixe. Les fils passent par un serre-câble de 3/8 po et se relient aux fils et à la vis de mise à la terre dans le boîtier électrique, sous un dégagement de 2 3/8 po.
Pour le promoteur, ces deux options arrivent de l'usine sur le même appareil : rien à modifier sur le chantier, aucun cordon à retirer, aucun raccord à déplacer.
Chiffres de rendement
- Efficacité de récupération sensible : 70 % à 0 °C (42 pcm), 75 % ajustée.
- À −25 °C : 55 % à 53 pcm, au-delà du seuil de 54 % de la section 9.32 du Code pour le Grand Montréal.
- Récupération totale en climatisation : 50 % à 35 °C.
- Consommation : 42 W à 42 pcm (1,0 pcm/W), et 368 kWh par an selon l'estimation de la fiche technique ci-dessus.
- Courant de fonctionnement : 0,6 A.
Le dégivrage se déclenche à −10 °C et moins : le ventilateur d'alimentation s'arrête, l'évacuation passe en haute vitesse, puis l'appareil reprend son cycle normal.
Les commandes dans un immeuble de condos
Pour un promoteur, la question est souvent de savoir qui réglera l'appareil. Fantech recommande pour la série FIT 80 la commande ECO-Feel Auto IAQ : un capteur de COV, un mode automatique qui s'adapte à la saison, aucun bouton ni aucune pile. L'occupant n'a rien à régler. Si vous préférez laisser un choix, l'EDF3 offre trois modes (Econo, 20 minutes par heure, continu). Dans les salles de bain, des minuteries RTS2 ou RTS5 font passer le VRE en haute vitesse; jusqu'à cinq peuvent être branchées sur un même appareil.
Le boîtier est en acier galvanisé G90 de calibre 22, avec une porte prépeinte et un isolant de polystyrène expansé haute densité de 3/4 po. Les ventilateurs, équilibrés en usine, tournent sur des roulements à billes scellés qui ne demandent aucune lubrification.
Dimensions, poids et entretien
Le boîtier mesure 20,63 × 18,19 × 10,06 po et pèse 29 lb avec le noyau. Il ne demande aucun drain. Ses deux filtres MERV 3 lavables (9 1/2 × 8 1/2 po) peuvent être remplacés par des MERV 8 (484397) ou MERV 13 (484396). Prévoyez 8 1/2 po devant la porte : c'est l'espace qu'il faut pour sortir le noyau de 10 × 10 po.
Garantie
La garantie limitée Fantech est de 7 ans sur les moteurs et de 5 ans sur le noyau et les composants électriques.
Installation par AirGreen dans la région de Montréal
Nous installons des VRE dans les condos et les maisons de ville de Montréal, de Laval, de Longueuil, de la Rive-Nord et de la Rive-Sud. Chaque projet commence par un calcul pièce par pièce selon CSA F326. Nous posons ensuite les conduits dédiés, les hottes extérieures et l'appareil, puis nous équilibrons l'alimentation et l'évacuation au débit calculé.
Le FIT 80E-M-HC est inscrit sous le no 2005303 à la section III du répertoire HVI. Il peut donc être admissible à l'aide Rénoclimat de 500 $, si la cote ÉnerGuide s'améliore entre les deux évaluations et si l'évaluation a été faite avant le début des travaux.
Soumission gratuite au 514 316-2973 ou à sales@airgreen.ca.