Échangeur d'Air Fantech ERV FIT 80E-M-HC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord

In stock
SKU: FIT 80E-M-HC
78 cfm net800 to 1,400 sq ft55% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
55%
At −25 °CCode: 54% minimum
70%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench93 cfm
0.4 in · with ducts78 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-MMirrored version: dwelling-side ports on the left

On the FIT 80E, the dwelling's supply and return air connect on the right-hand side; on the FIT 80E-M-HC, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.

-HCHard-connect version shipped without a cord

The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 80E-M-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.

55%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005303Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm. Most spec sheets show only the first number, precisely because it looks better.

42 WMeasured at the airflow it actually runs at

Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

4 inWhat it needs on site

4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005303. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

4 in ductsCollar diameter
Side connectionSide ports
29 lbUnit weight
20.63 × 18.19 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
93 cfm
Net airflow at 0.4 in. w.g.
78 cfm
SRE at 0 °C (42 cfm)
70%
SRE at −25 °C (53 cfm)
55%
ASE at 0 °C
75%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Side ports
Duct collars
4 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
Dimensions (L × D × H)
20.63 × 18.19 × 10.06 in
Weight
29 lb
Power supply
120 V
HVI certification (Section III)
2005303
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005303). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Fantech FIT 80E-M-HCYou are here800 to 1,400 sq ft78 cfm
Fantech HERO 100ELarger1,200 to 1,900 sq ft102 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Pour les condos chauffés aux plinthes, en plan inversé et câblés en fixe

Beaucoup de condos du Grand Montréal n'ont pas de fournaise : ils sont chauffés par plinthes électriques, parfois avec une thermopompe murale. L'échangeur d'air y a son propre réseau de conduits, et un volet motorisé n'a pas de rôle à jouer. Le Fantech FIT 80E-M-HC est conçu pour ce contexte : raccords du logement à gauche (-M) et alimentation électrique permanente, sans cordon (-HC).

Ce ventilateur récupérateur d'énergie (VRE) offre un débit net de 78 pcm à 0,4 po et de 93 pcm à 0,2 po, dans un boîtier de 10,06 po d'épaisseur. Le format 80 convient aux logements dont le calcul de ventilation reste sous ce débit.

L'installation entièrement dédiée

Fantech présente cette méthode comme la meilleure en construction neuve. L'air neuf est distribué aux chambres et aux pièces principales, et l'air vicié est repris dans la salle de bain, la cuisine ou la salle de lavage, sans passer par un système à air pulsé. Le fabricant la suggère avec les plinthes électriques, le chauffage hydronique, le plancher radiant et la thermopompe murale. Les grilles d'alimentation se placent haut sur le mur ou au plafond, avec des diffuseurs qui répartissent l'air sans courant désagréable.

Deux options, deux raisons

La version miroir sert les immeubles où la moitié des unités est construite à l'envers de l'autre : les raccords arrivent du côté gauche, et le plan de conduits reste simple. La version sans cordon répond aux codes et aux devis qui exigent un raccordement fixe. Les fils passent par un serre-câble de 3/8 po et se relient aux fils et à la vis de mise à la terre dans le boîtier électrique, sous un dégagement de 2 3/8 po.

Pour le promoteur, ces deux options arrivent de l'usine sur le même appareil : rien à modifier sur le chantier, aucun cordon à retirer, aucun raccord à déplacer.

Chiffres de rendement

  • Efficacité de récupération sensible : 70 % à 0 °C (42 pcm), 75 % ajustée.
  • À −25 °C : 55 % à 53 pcm, au-delà du seuil de 54 % de la section 9.32 du Code pour le Grand Montréal.
  • Récupération totale en climatisation : 50 % à 35 °C.
  • Consommation : 42 W à 42 pcm (1,0 pcm/W), et 368 kWh par an selon l'estimation de la fiche technique ci-dessus.
  • Courant de fonctionnement : 0,6 A.

Le dégivrage se déclenche à −10 °C et moins : le ventilateur d'alimentation s'arrête, l'évacuation passe en haute vitesse, puis l'appareil reprend son cycle normal.

Les commandes dans un immeuble de condos

Pour un promoteur, la question est souvent de savoir qui réglera l'appareil. Fantech recommande pour la série FIT 80 la commande ECO-Feel Auto IAQ : un capteur de COV, un mode automatique qui s'adapte à la saison, aucun bouton ni aucune pile. L'occupant n'a rien à régler. Si vous préférez laisser un choix, l'EDF3 offre trois modes (Econo, 20 minutes par heure, continu). Dans les salles de bain, des minuteries RTS2 ou RTS5 font passer le VRE en haute vitesse; jusqu'à cinq peuvent être branchées sur un même appareil.

Le boîtier est en acier galvanisé G90 de calibre 22, avec une porte prépeinte et un isolant de polystyrène expansé haute densité de 3/4 po. Les ventilateurs, équilibrés en usine, tournent sur des roulements à billes scellés qui ne demandent aucune lubrification.

Dimensions, poids et entretien

Le boîtier mesure 20,63 × 18,19 × 10,06 po et pèse 29 lb avec le noyau. Il ne demande aucun drain. Ses deux filtres MERV 3 lavables (9 1/2 × 8 1/2 po) peuvent être remplacés par des MERV 8 (484397) ou MERV 13 (484396). Prévoyez 8 1/2 po devant la porte : c'est l'espace qu'il faut pour sortir le noyau de 10 × 10 po.

Garantie

La garantie limitée Fantech est de 7 ans sur les moteurs et de 5 ans sur le noyau et les composants électriques.

Installation par AirGreen dans la région de Montréal

Nous installons des VRE dans les condos et les maisons de ville de Montréal, de Laval, de Longueuil, de la Rive-Nord et de la Rive-Sud. Chaque projet commence par un calcul pièce par pièce selon CSA F326. Nous posons ensuite les conduits dédiés, les hottes extérieures et l'appareil, puis nous équilibrons l'alimentation et l'évacuation au débit calculé.

Le FIT 80E-M-HC est inscrit sous le no 2005303 à la section III du répertoire HVI. Il peut donc être admissible à l'aide Rénoclimat de 500 $, si la cote ÉnerGuide s'améliore entre les deux évaluations et si l'évaluation a été faite avant le début des travaux.

Soumission gratuite au 514 316-2973 ou à sales@airgreen.ca.