78 cfm net800 to 1,400 sq ft55% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
55%
At −25 °CCode: 54% minimum
70%
At 0 °CCertified at 42 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench93 cfm
0.4 in · with ducts78 cfm

$40.99

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

42W
Running continuously
368kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-MMirrored version: dwelling-side ports on the left

On the FIT 80E, the dwelling's supply and return air connect on the right-hand side; on the FIT 80E-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.

ECO-FeelRecommended control: ECO-Feel Auto IAQ

The FIT 80E submittal sheet recommends the ECO-Feel Auto IAQ control. With a built-in VOC sensor, it selects the operating mode and speed for the season, with no user interface: all its settings are made at the factory.

55%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005300Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm. Most spec sheets show only the first number, precisely because it looks better.

42 WMeasured at the airflow it actually runs at

Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

4 inWhat it needs on site

4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005300. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

4 in ductsCollar diameter
Side connectionSide ports
29 lbUnit weight
20.63 × 18.19 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
93 cfm
Net airflow at 0.4 in. w.g.
78 cfm
SRE at 0 °C (42 cfm)
70%
SRE at −25 °C (53 cfm)
55%
ASE at 0 °C
75%
Power draw
42 W
Efficacy
1.0 cfm/W
Type
ERV
Connection
Side ports
Duct collars
4 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
Dimensions (L × D × H)
20.63 × 18.19 × 10.06 in
Weight
29 lb
Power supply
120 V
HVI certification (Section III)
2005300
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005300). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Fantech FIT 80E-MYou are here800 to 1,400 sq ft78 cfm
Fantech HERO 100ELarger1,200 to 1,900 sq ft102 cfm

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

La version miroir du FIT 80E, pour les plans inversés

Dans un immeuble de condos, deux logements voisins sont souvent construits en miroir : la salle mécanique de l'un est à gauche, celle de l'autre à droite. Le Fantech FIT 80E-M existe pour cette situation. Sur le FIT 80E standard, l'alimentation et le retour d'air du logement se raccordent du côté droit; sur le 80E-M, ils passent du côté gauche. Les conduits arrivent ainsi en ligne droite sur l'appareil, sans détour.

Il s'agit du même ventilateur récupérateur d'énergie (VRE) que le modèle de base, avec un débit net homologué de 78 pcm à 0,4 po et de 93 pcm à 0,2 po. Il est livré avec cordon et sans volet motorisé.

Pourquoi l'orientation compte

Chaque coude et chaque longueur de conduit ajoutent de la résistance. Fantech demande des conduits courts, le moins de coudes possible, des coudes à 45° plutôt qu'à 90° et des raccords en Y plutôt qu'en T. Avec un appareil orienté du bon côté, ces consignes se respectent sans compromis, et le débit réel reste proche de celui de la fiche. Pour l'installateur, le manuel est simple : les schémas se lisent à l'inverse. Pour un promoteur, commander la bonne version dès le départ évite aussi de modifier un placard mécanique déjà construit.

Une commande sans réglage pour l'occupant

La fiche de soumission du FIT 80E recommande la commande ECO-Feel Auto IAQ. Elle contient un capteur de COV et choisit elle-même le mode et la vitesse selon la saison. Elle n'a ni pile ni interface : tous ses réglages sont faits en usine. Pour un promoteur ou un gestionnaire d'immeuble, c'est une façon d'éviter qu'un locataire coupe la ventilation. D'autres commandes Fantech sont compatibles si vous préférez un réglage manuel, comme l'EDF3 et ses modes Econo, 20 minutes par heure et continu.

Efficacité et consommation

Mesurée à 42 pcm, l'efficacité de récupération sensible est de 70 % à 0 °C; la valeur ajustée est de 75 %. À −25 °C et 53 pcm, elle reste à 55 %, ce qui respecte le minimum de 54 % prévu à la section 9.32 du Code pour le Grand Montréal. La consommation est de 42 W à 42 pcm, soit 1,0 pcm/W. À −10 °C et moins, le dégivrage arrête l'alimentation et pousse l'évacuation à haute vitesse le temps du cycle.

Fiche d'installation

  • Dimensions de 20,63 × 18,19 × 10,06 po, 29 lb avec le noyau.
  • Raccords latéraux ronds de 4 po; aucun drain.
  • Montage au plafond ou au mur avec le support inclus.
  • Noyau à membrane de 10 × 10 po, lavable à l'eau.
  • Deux filtres électrostatiques MERV 3 de 9 1/2 × 8 1/2 po; MERV 8 (484397) et MERV 13 (484396) en option.

Mise en service

À la première mise sous tension, le FIT 80E-M passe dix secondes en dégivrage par évacuation seule : le ventilateur d'évacuation tourne en haute vitesse et celui d'alimentation reste arrêté. Il adopte ensuite le mode choisi. Sans commande murale, un sélecteur près du boîtier électrique offre trois positions : MIN, AUTO (attente) et MAX. Une fois une commande numérique branchée, c'est elle qui fixe la vitesse. Nous vérifions chaque position avant de remettre l'appareil à l'occupant, puis nous remplissons le rapport de mise en service de Fantech.

Un déshumidistat mural MDEH1 peut s'ajouter : quand l'humidité dépasse le réglage, il force la haute vitesse. Fantech suggère de le régler au-dessus de 80 % l'été.

Entretien et garantie

Les filtres se lavent à l'eau tiède savonneuse. Le noyau se rince à l'eau du robinet jusqu'à ce que l'eau sorte claire, puis sèche environ deux à trois heures avant d'être remis en place. Si l'appareil est au plafond, prudence en ouvrant la porte : noyau et filtres peuvent tomber. Garantie Fantech : 5 ans sur le noyau, 7 ans sur les moteurs, 5 ans sur les pièces électriques.

AirGreen installe le FIT 80E-M dans le Grand Montréal

Nous travaillons avec des propriétaires et des promoteurs à Montréal, à Laval, à Longueuil, sur la Rive-Nord et sur la Rive-Sud. Pour un immeuble, nous calculons la ventilation de chaque logement selon CSA F326, nous choisissons la version standard ou miroir d'après le plan, puis nous équilibrons chaque appareil au débit prévu.

Le FIT 80E-M figure à la section III du répertoire HVI sous le no 2005300. Une installation peut être admissible à l'aide Rénoclimat de 500 $ si la cote ÉnerGuide s'améliore entre les deux évaluations, à condition que l'évaluation soit faite avant le début des travaux.

Demandez une soumission gratuite au 514 316-2973 ou à sales@airgreen.ca.