Fantech ERV FIT 80E-M Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 78 cfm net, enough to ventilate 800 to 1,400 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 78 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$40.99
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 55% at 53 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 42 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-MMirrored version: dwelling-side ports on the left
On the FIT 80E, the dwelling's supply and return air connect on the right-hand side; on the FIT 80E-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
ECO-FeelRecommended control: ECO-Feel Auto IAQ
The FIT 80E submittal sheet recommends the ECO-Feel Auto IAQ control. With a built-in VOC sensor, it selects the operating mode and speed for the season, with no user interface: all its settings are made at the factory.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 53 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005300Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 93 to 78 cfm.
42 WMeasured at the airflow it actually runs at
Its 70% at 0 °C is certified at 42 cfm, the continuous airflow of a typical home. At that setting it draws 42 W, or about 368 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 29 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005300) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 93 cfm
- Net airflow at 0.4 in. w.g.
- 78 cfm
- SRE at 0 °C (42 cfm)
- 70%
- SRE at −25 °C (53 cfm)
- 55%
- ASE at 0 °C
- 75%
- Power draw
- 42 W
- Efficacy
- 1.0 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (9 1/2 × 8 1/2 in); optional MERV 8 (484397) and MERV 13 (484396)
- Dimensions (L × D × H)
- 20.63 × 18.19 × 10.06 in
- Weight
- 29 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005300
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005300). Annual consumption calculated at 42 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The mirror version of the FIT 80E, for reversed floor plans
In a condo building, two neighbouring units are often built as mirror images: one has its mechanical room on the left, the other on the right. The Fantech FIT 80E-M exists for this situation. On the standard FIT 80E, the dwelling's supply and return air connect on the right side; on the 80E-M, they move to the left side. The ducts thus reach the unit in a straight line, with no detour.
It is the same energy recovery ventilator (ERV) as the base model, with an HVI-certified net airflow of 78 cfm at 0.4 in. and 93 cfm at 0.2 in. It ships with a cord and without a motorized damper.
Why orientation matters
Every elbow and every length of duct adds resistance. Fantech calls for short ducts, as few elbows as possible, 45° elbows rather than 90° ones and Y fittings rather than T fittings. With a unit facing the right way, these guidelines are met without compromise, and the actual airflow stays close to the one on the sheet. For the installer, the manual is simple: the diagrams are read in reverse. For a developer, ordering the right version from the start also avoids modifying a mechanical closet that is already built.
A control with no settings for the occupant
The FIT 80E spec sheet recommends the ECO-Feel Auto IAQ control. It contains a VOC sensor and chooses the mode and speed by itself according to the season. It has no battery and no interface: all its settings are made at the factory. For a developer or a building manager, it is a way to keep a tenant from shutting off the ventilation. Other Fantech controls are compatible if you prefer manual adjustment, such as the EDF3 with its Econo, 20 minutes per hour and continuous modes.
Efficiency and power consumption
Measured at 42 cfm, the sensible recovery efficiency is 70% at 0 °C; the adjusted value is 75%. At −25 °C and 53 cfm, it remains at 55%, which meets the 54% minimum set out in section 9.32 of the Code for Greater Montreal. Power consumption is 42 W at 42 cfm, or 1.0 cfm/W. At −10 °C and below, defrost stops the supply and pushes the exhaust to high speed for the length of the cycle.
Installation sheet
- Dimensions of 20.63 × 18.19 × 10.06 in., 29 lb with the core.
- 4 in. round side connections; no drain.
- Ceiling or wall mounting with the included bracket.
- 10 × 10 in. membrane core, washable with water.
- Two MERV 3 electrostatic filters, 9 1/2 × 8 1/2 in.; MERV 8 (484397) and MERV 13 (484396) optional.
Commissioning
When first powered up, the FIT 80E-M spends ten seconds in exhaust-only defrost: the exhaust fan runs at high speed and the supply fan stays off. It then switches to the selected mode. Without a wall control, a selector near the electrical box offers three positions: MIN, AUTO (standby) and MAX. Once a digital control is connected, it sets the speed. We check each position before handing the unit over to the occupant, then fill out Fantech's commissioning report.
An MDEH1 wall dehumidistat can be added: when humidity exceeds the setting, it forces high speed. Fantech suggests setting it above 80% in summer.
Maintenance and warranty
The filters are washed in warm soapy water. The core is rinsed under tap water until the water runs clear, then dries for about two to three hours before going back in. If the unit is on the ceiling, be careful when opening the door: the core and filters can fall out. Fantech warranty: 5 years on the core, 7 years on the motors, 5 years on the electrical parts.
AirGreen installs the FIT 80E-M in Greater Montreal
We work with owners and developers in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a building, we calculate the ventilation of each dwelling according to CSA F326, choose the standard or mirror version based on the floor plan, then balance each unit to the design airflow.
The FIT 80E-M is listed in Section III of the HVI directory under No. 2005300, which makes its airflows and efficiencies verifiable by anyone. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already opened under the program's transition rules.
Ask for a free quote at 514 316-2973 or sales@airgreen.ca.