Fantech HRV HERO 150H Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: HERO 150H
150 cfm net1,700 to 2,800 sq ft63% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeLifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 150 cfm net, enough to ventilate 1,700 to 2,800 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 150 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
63%
At −25 °CCode: 54% minimum
80%
At 0 °CCertified at 72 cfm
Net airflowThe ducts cost it 17 cfm
0.2 in · test bench167 cfm
0.4 in · with ducts150 cfm

$58.56

Electricity per year

Less than a 100 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

60W
Running continuously
526kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 63% at 72 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 60 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

14 inCore removal: 14 in free in front of the door

The HERO 150H's core and filters come out through the front door, held by two latches under the unit. Fantech calls for 14 in (355 mm) in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.

LoopDrain tube supplied, installed with a loop

The HERO 150H comes with its drain tube. It attaches to the unit's fitting, then a loop is formed in it as shown in Fantech's drawing before it is routed to the drain.

63%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 72 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.

2505381Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−17 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 167 to 150 cfm.

60 WMeasured at the airflow it actually runs at

Its 80% at 0 °C is certified at 72 cfm, the continuous airflow of a typical home. At that setting it draws 60 W, or about 526 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

6 inWhat it needs on site

6 in ducts, top connection and a condensate drain. It weighs 51 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2505381) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
51 lbUnit weight
27.88 × 13.38 × 24.88 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
167 cfm
Net airflow at 0.4 in. w.g.
150 cfm
SRE at 0 °C (72 cfm)
80%
SRE at −25 °C (72 cfm)
63%
ASE at 0 °C
86%
Power draw
60 W
Efficacy
1.2 cfm/W
Type
HRV
Connection
Top ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable electrostatic MERV 3 panel filters (7 7/8 × 9 13/16 in); optional MERV 8 (428526) or MERV 13 (428548), not washable
Dimensions (L × D × H)
27.88 × 13.38 × 24.88 in
Weight
51 lb
Power supply
120 V
HVI certification (Section III)
2505381
Warranty — core
Lifetime
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505381). Annual consumption calculated at 60 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The mid-size HERO HRV, drain included

The Fantech HERO 150H is a heat recovery ventilator (HRV) for the typical suburban single-family home: a bungalow with a finished basement, a two-storey house, a semi-detached house. Its net airflow is 150 cfm at 0.4 in., and 167 cfm at 0.2 in.

It is an air exchanger with conventional motors, simple and proven. It recovers heat from the stale air and lets the moisture out, which suits homes that tend to have too much humidity in winter.

A supplied drain, installed with a loop

An HRV produces condensation, and the HERO 150H must be connected to a drain. It comes with its drain tube. The tube is attached to the unit's fitting, pulled lightly to make sure it holds, then formed into a loop as Fantech's diagram shows before being routed to the drain.

This loop holds a little water and keeps air from passing through the tube. Without it, the unit can draw air and odours in through the drain. It is a detail we check at every start-up.

Core removal: 14 in. in front of the door

The core and filters come out through the front door, held by two latches at the bottom of the unit. Fantech calls for 14 in. of free space in front of the door to remove the core, and 2 3/8 in. above the electrical box for wiring. We choose the location based on these clearances, so that maintenance is still easy ten years from now.

Efficiency and power consumption

According to HVI, the sensible recovery efficiency is 80% at 72 cfm and 0 °C, and the adjusted sensible efficiency is 86%. At −25 °C, it is still 63% at the same 72 cfm airflow. That is above the 54% threshold in section 9.32 of the Québec Construction Code for Greater Montreal.

At the 72 cfm test point, it draws 60 W, or 1.2 cfm/W. Running continuously, that comes to about 526 kWh per year, roughly $59 at Hydro-Québec Rate D (11.142¢/kWh). If you want to bring that figure down, the HERO 150H-EC uses the same cabinet with EC motors.

Defrost works by recirculation: a damper opens on the indoor side and house air clears the core, without drawing in outdoor air during the cycle.

Installation

  • Dimensions: 27.88 × 13.38 × 24.88 in. (L × D × H)
  • Weight: 51 lb
  • Connections: 6 in., round, on top (vertical connection)
  • Power supply: 120 V
  • Drain: required, tube supplied

The unit mounts on the wall on the supplied bracket or hangs from the joists with chains and springs. For the 6 in. connections, the manual calls for main ducts of the same diameter or larger, galvanized ducts to the main rooms, and insulated flexible duct only where needed.

Filters

Two washable electrostatic MERV 3 filters measuring 7 7/8 × 9 13/16 in. are supplied. They wash in warm, soapy water. As options, Fantech offers MERV 8 (428526) or MERV 13 (428548) filters, which are replaced instead of washed. A finer filter adds resistance: we plan for it in the balancing.

At the start of each winter, also check that the drain tube is not clogged and that the loop is still in place. If the water does not drain, it builds up in the unit. We show you these checks at start-up.

Warranty

Fantech warrants the core for life, the fan motors for 7 years, and the electrical components and the damper motor for 5 years. The unit is designed for residential use only.

The HERO 150H is certified in Section III of the HVI directory (number 2505381): its airflows and efficiencies are published and anyone can check them. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already opened under the program's transition rules.

Installation by AirGreen in Greater Montreal

We calculate your home's ventilation airflow room by room, under the CSA F326 standard, before settling on the HERO 150H. We also check where the drain runs and where the ducts can go up, because a good unit in the wrong place ventilates poorly.

After installation, we balance supply and exhaust with a manometer, to the calculated airflow. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.

Free quote: 514 316-2973 or sales@airgreen.ca.