Fantech HRV HERO 250H-EC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 252 cfm net, enough to ventilate 3,000 to 4,800 sq ft. Choose your home's living area.
It's the right size.
For a 3,200 to 5,000 sq ft home, about 215 cfm of air needs to be renewed continuously. This unit delivers 252 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$33.19
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 63% at 83 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 34 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
252 cfmLargest HERO: 80 to 252 cfm, EC motors
With electronically commutated motors, the HERO 250H-EC covers 80 to 252 cfm at 0.4 in, the widest range in the HERO series. Fantech's guide gives it 2.5 cfm/W fan efficacy at 0 °C; it shares the HERO 200H cabinet.
16 inCore removal: 16 in free in front of the door
The HERO 250H-EC's core and filters come out through the front door, held by two latches under the unit. Fantech calls for 16 in (406 mm) in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.
63%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.
2505149Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 267 to 252 cfm.
34 WMeasured at the airflow it actually runs at
Its 82% at 0 °C is certified at 85 cfm, the continuous airflow of a typical home. At that setting it draws 34 W, or about 298 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection and a condensate drain. It weighs 57 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2505149) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 267 cfm
- Net airflow at 0.4 in. w.g.
- 252 cfm
- SRE at 0 °C (85 cfm)
- 82%
- SRE at −25 °C (83 cfm)
- 63%
- ASE at 0 °C
- 85%
- Power draw
- 34 W
- Efficacy
- 2.5 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable electrostatic MERV 3 panel filters; optional MERV 8 (428527) or MERV 13 (428549), not washable
- Dimensions (L × D × H)
- 27.88 × 15.38 × 24.88 in
- Weight
- 57 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505149
- Warranty — core
- Lifetime
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505149). Annual consumption calculated at 34 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The largest HERO, for homes with a large floor area
The Fantech HERO 250H-EC is the heat recovery ventilator (HRV) with the highest airflow in the HERO series: 252 cfm net at 0.4 in., and 267 cfm at 0.2 in. Thanks to its electronically commutated motors, it covers a range of 80 to 252 cfm at 0.4 in.
It is aimed at large homes, residences with several bathrooms and very airtight new homes where the ventilation calculation exceeds 200 cfm. For these projects, it saves installing two air exchangers.
The HERO 200H cabinet, a third of the power consumption
The HERO 250H-EC shares the HERO 200H cabinet. The comparison is direct, because both were tested by HVI at the same 85 cfm airflow. There, the HERO 200H draws 98 W; the HERO 250H-EC, 34 W. Fantech's guide gives the 250H-EC a fan efficiency of 2.5 cfm/W at 0 °C.
Running continuously, that comes to about 298 kWh per year for the HERO 250H-EC, roughly $33 of electricity at Hydro-Québec Rate D (11.142¢/kWh), versus about 858 kWh for the HERO 200H. For the highest-airflow unit in the series, running all year, the gap matters.
Recovery efficiency
According to HVI, the sensible recovery efficiency is 82% at 85 cfm and 0 °C, and the adjusted sensible efficiency is 85%. At −25 °C, it is still 63% (measured at 83 cfm), above the 54% threshold in section 9.32 of the Québec Construction Code for Greater Montreal.
Defrost works by recirculation: an internal damper opens on the indoor side and house air clears the core. The unit does not draw in outdoor air during the cycle.
Core removal: 16 in. in front of the door
The core and filters come out through the front door, held by two latches at the bottom of the unit. Fantech calls for 16 in. of free space in front of the door to remove the core and 2 3/8 in. above the electrical box for wiring. In a mechanical room already taken up by a furnace and a water heater, those 16 in. have to be reserved at the planning stage.
Installation
- Dimensions: 27.88 × 15.38 × 24.88 in. (L × D × H)
- Weight: 57 lb
- Connections: 6 in., round, on top (vertical connection)
- Power supply: 120 V
- Drain: required, tube supplied
The drain tube is supplied; it is installed with a loop before going to the drain. At this airflow, the duct system makes all the difference: main ducts at least the diameter of the 6 in. connections, galvanized ducts to the main rooms, 45° elbows and Y fittings. An overly restrictive duct system would keep the unit from reaching its airflow.
Filters
The HERO 250H-EC comes with two washable electrostatic MERV 3 filters, to be washed in warm, soapy water. Options: MERV 8 (428527) or MERV 13 (428549), which are not washable. A finer filter adds static pressure; we take it into account when balancing.
The core comes out through the same door as the filters. At the start of each winter, check that the drain tube flows properly and that its loop is in place.
Fantech recommends a fully dedicated installation, with its own ducts, to keep power consumption down. With a unit of this size with EC motors, that is the approach we favour.
Warranty
Fantech warrants the core for life, the fan motors for 7 years, and the electrical components and the damper motor for 5 years. The unit is designed for residential use only.
The HERO 250H-EC is certified in Section III of the HVI directory (number 2505149): its airflows and efficiencies are published and anyone can check them. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or ERV; only files already opened under the program's transition rules remain eligible.
Installation by AirGreen in Greater Montreal
A large home calls for a serious calculation. We establish the required airflow room by room under the CSA F326 standard, then design the duct system so that the HERO 250H-EC delivers that airflow without strain.
At start-up, we balance supply and exhaust with a manometer, to the calculated airflow. Our technicians install in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Free quote: 514 316-2973 or sales@airgreen.ca.