Échangeur d'Air Fantech HRV HERO 250H-EC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord

In stock
SKU: HERO 250H-EC
252 cfm net3,000 to 4,800 sq ft63% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Lifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 252 cfm net, enough to ventilate 3,000 to 4,800 sq ft. Choose your home's living area.

It's the right size.

For a 3,200 to 5,000 sq ft home, about 215 cfm of air needs to be renewed continuously. This unit delivers 252 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
63%
At −25 °CCode: 54% minimum
82%
At 0 °CCertified at 85 cfm
Net airflowThe ducts cost it 15 cfm
0.2 in · test bench267 cfm
0.4 in · with ducts252 cfm

$33.19

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

34W
Running continuously
298kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 63% at 83 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 34 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

252 cfmLargest HERO: 80 to 252 cfm, EC motors

With electronically commutated motors, the HERO 250H-EC covers 80 to 252 cfm at 0.4 in, the widest range in the HERO series. Fantech's guide gives it 2.5 cfm/W fan efficacy at 0 °C; it shares the HERO 200H cabinet.

16 inCore removal: 16 in free in front of the door

The HERO 250H-EC's core and filters come out through the front door, held by two latches under the unit. Fantech calls for 16 in (406 mm) in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.

63%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, the problem is almost always too much humidity, not too little.

2505149Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−15 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 267 to 252 cfm. Most spec sheets show only the first number, precisely because it looks better.

34 WMeasured at the airflow it actually runs at

Its 82% at 0 °C is certified at 85 cfm, the continuous airflow of a typical home. At that setting it draws 34 W, or about 298 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

6 inWhat it needs on site

6 in ducts, top connection and a condensate drain. It weighs 57 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2505149. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
57 lbUnit weight
27.88 × 15.38 × 24.88 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
267 cfm
Net airflow at 0.4 in. w.g.
252 cfm
SRE at 0 °C (85 cfm)
82%
SRE at −25 °C (83 cfm)
63%
ASE at 0 °C
85%
Power draw
34 W
Efficacy
2.5 cfm/W
Type
HRV
Connection
Top ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable electrostatic MERV 3 panel filters; optional MERV 8 (428527) or MERV 13 (428549), not washable
Dimensions (L × D × H)
27.88 × 15.38 × 24.88 in
Weight
57 lb
Power supply
120 V
HVI certification (Section III)
2505149
Warranty — core
Lifetime
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505149). Annual consumption calculated at 34 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Le plus grand HERO, pour les maisons de grande superficie

Le Fantech HERO 250H-EC est le ventilateur récupérateur de chaleur (VRC) au plus fort débit de la série HERO : 252 pcm nets à 0,4 po, et 267 pcm à 0,2 po. Grâce à ses moteurs à commutation électronique, il couvre une plage de 80 à 252 pcm à 0,4 po.

Il s'adresse aux grandes maisons, aux résidences avec plusieurs salles de bain et aux maisons neuves très étanches où le calcul de ventilation dépasse 200 pcm. Pour ces projets, il évite de poser deux échangeurs d'air.

Le boîtier du HERO 200H, un tiers de la consommation

Le HERO 250H-EC partage le boîtier du HERO 200H. La comparaison est directe, car les deux ont été testés par HVI au même débit de 85 pcm. Le HERO 200H y consomme 98 W; le HERO 250H-EC, 34 W. Le guide de Fantech donne au 250H-EC une efficacité des ventilateurs de 2,5 pcm/W à 0 °C.

En marche continue, cela représente environ 298 kWh par année pour le HERO 250H-EC, à peu près 33 $ d'électricité au tarif D d'Hydro-Québec (11,142 ¢/kWh), contre environ 858 kWh pour le HERO 200H. Pour l'appareil au plus fort débit de la série, qui tourne toute l'année, l'écart compte.

Efficacité de récupération

Selon HVI, l'efficacité de récupération sensible est de 82 % à 85 pcm et à 0 °C, et l'efficacité sensible ajustée de 85 %. À −25 °C, elle reste à 63 % (mesurée à 83 pcm), au-dessus du seuil de 54 % de la section 9.32 du Code de construction du Québec pour le Grand Montréal.

Le dégivrage se fait par recirculation : un volet interne s'ouvre du côté intérieur et l'air de la maison dégage le noyau. L'appareil n'aspire pas d'air extérieur pendant le cycle.

Retrait du noyau : 16 po devant la porte

Le noyau et les filtres sortent par la porte avant, retenue par deux loquets au bas de l'appareil. Fantech demande 16 po libres devant la porte pour retirer le noyau et 2 3/8 po au-dessus du boîtier électrique pour le câblage. Dans une salle mécanique déjà occupée par une fournaise et un chauffe-eau, ces 16 po se réservent dès le plan.

Installation

  • Dimensions : 27,88 × 15,38 × 24,88 po (L × P × H)
  • Poids : 57 lb
  • Raccords : 6 po, ronds, sur le dessus (raccordement vertical)
  • Alimentation : 120 V
  • Drain : requis, tube fourni

Le tube de drainage est fourni; il se pose avec une boucle avant d'aller au drain. À ce débit, le réseau de conduits fait toute la différence : conduits principaux au moins du diamètre des raccords de 6 po, conduits galvanisés vers les pièces principales, coudes à 45° et raccords en Y. Un réseau trop restrictif empêcherait l'appareil d'atteindre son débit.

Filtres

Le HERO 250H-EC est livré avec deux filtres électrostatiques lavables MERV 3, à laver à l'eau tiède savonneuse. En option : MERV 8 (428527) ou MERV 13 (428549), non lavables. Un filtre plus fin ajoute de la pression statique; nous en tenons compte au moment de l'équilibrage.

Le noyau sort par la même porte que les filtres. Au début de chaque hiver, vérifiez que le tube de drainage s'écoule bien et que sa boucle est en place.

Fantech recommande une installation entièrement dédiée, avec ses propres conduits, pour limiter la consommation. Avec un appareil de cette taille à moteurs EC, c'est l'approche que nous privilégions.

Garantie

Fantech garantit le noyau à vie, les moteurs des ventilateurs 7 ans, et les composants électriques ainsi que le moteur du volet 5 ans. L'appareil est conçu pour un usage résidentiel seulement.

Le HERO 250H-EC est admissible à l'aide Rénoclimat de 500 $ si l'appareil est homologué à la section III du répertoire HVI (c'est le cas du HERO 250H-EC, numéro HVI 2505149) et si la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux. Nous vous indiquons à quel moment la demander pour ne pas perdre l'aide.

Installation par AirGreen dans le Grand Montréal

Une grande maison demande un calcul sérieux. Nous établissons le débit requis pièce par pièce selon la norme CSA F326, puis nous dessinons le réseau de conduits pour que le HERO 250H-EC livre ce débit sans forcer.

À la mise en service, nous équilibrons l'alimentation et l'évacuation au manomètre, au débit calculé. Nos techniciens installent à Montréal, Laval, Longueuil, sur la Rive-Nord et la Rive-Sud.

Soumission gratuite : 514 316-2973 ou sales@airgreen.ca.