Is it the right size for your home?
It delivers 57 cfm net, enough to ventilate 600 to 1,000 sq ft. Choose your home's living area.
It's the right size.
For a condo or a home under 900 sq ft, about 37 cfm of air needs to be renewed continuously. This unit delivers 57 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
Airflow and efficiency: manufacturer's published data.
What you should know about this one
Published, verifiable facts, not brochure claims.
CompactSmallest unit to date, says Lifebreath
Lifebreath presents it as its smallest unit to date and considers it ideal for small homes and townhouses where space is tight. It weighs 33 lb and connects through 4 in round collars on top.
TabsFour fold-out hanging tabs
To hang it, the four tabs at the front and back of the sides are bent out to about 45°, then the “S” hooks and the supplied adjustable straps are hooked through them.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
−11 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 68 to 57 cfm. Most spec sheets show only the first number, precisely because it looks better.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
4 inWhat it needs on site
4 in ducts, top connection and a condensate drain. It weighs 33 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 68 cfm
- Net airflow at 0.4 in. w.g.
- 57 cfm
- SRE at 0 °C (55 cfm)
- 70%
- Type
- ERV
- Connection
- Top ports
- Duct collars
- 4 in
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable MERV 6 filters (exhaust and supply)
- Dimensions (L × D × H)
- 18.75 × 17.88 × 19.25 in
- Weight
- 33 lb
- Power supply
- 120 V
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (English)
Airflow and efficiency: manufacturer's published data. The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
“Our smallest unit to date,” says Lifebreath
That is how Lifebreath presents the 30 ERV, an energy recovery ventilator (ERV) with a compact cabinet. It weighs 33 lb (15 kg) and connects through 4 in. (102 mm) round collars on top.
According to Lifebreath's spec sheet, its net airflow is 57 cfm at 0.4 in.; it rises to 68 cfm when the static pressure drops to 0.2 in.
An ERV rather than an HRV
The 30 ERV's cross-flow enthalpy core exchanges heat between the stale air and the fresh air, and it also transfers water vapour. In winter, the air in the home therefore dries out less; in summer, part of the outdoor humidity stays outside. The core slides out of the unit easily when it is time to clean it.
Efficiency
According to Lifebreath's spec sheet, the sensible recovery efficiency is 70% at 0 °C and 55 cfm, and the total recovery efficiency is 48% in cooling, at 35 °C and 63 cfm. The 30 ERV has no listing in the HVI directory, and Lifebreath publishes no efficiency at −25 °C: these values therefore come from the manufacturer alone. Without HVI certification or a −25 °C rating, the 30 ERV cannot show that it meets the requirement of art. 9.36.3.9 of the Québec Construction Code where it applies; if your project has to meet it, we will suggest a certified model.
Hanging by tabs
Four mounting tabs, at the front and back of the left and right sides, bend out to about 45° with a flat screwdriver. The “S” hooks go through their holes, then the supplied adjustable straps connect the unit to the joists, where they are fastened with four screws and four washers (not included). Lifebreath asks that no other holes be drilled in the cabinet.
Dimensions and connections
Lifebreath's drawing gives the cabinet three dimensions: 17 7/8 in. (454 mm), 18 3/4 in. (476 mm) and 19 1/4 in. (489 mm). On top, four 4 in. round collars take the ducts. Balancing dampers are located in all airstreams, and the airflows are measured at the door ports. In front of that door, leave 25 in. (635 mm) clear for service.
Defrost and drain
Defrost is done by fan: the fresh airstream is cut off, and the unit blows the still-warm stale air through the core at high speed. Lifebreath's installation manual calls for a drain; it only becomes optional if the outdoor temperature stays above −25 °C and the indoor humidity stays below 30%. We therefore plan for the drain.
Filters and control
One washable MERV 6 filter protects the stale air, another the fresh air. DIP switches on the circuit board set the high speed, and the unit leaves the factory at speed 5 (Hi 3). Lifebreath advises mounting the main control on a wall, in a central spot in the home.
Warranty
Lifebreath warrants the core for 5 years, as well as the motors and parts for 5 years.
Which home it suits
Lifebreath considers it ideal for small homes and townhouses where space is tight, and the numbers point the same way: of the Lifebreath units we offer, the 30 ERV is the lightest and the one that delivers the least air. We therefore suggest it for a home with modest needs where room is short (a row house, a small bungalow, a basement converted into a self-contained unit), all the more since its 4 in. ducts run more easily through an existing building. If the home needs more air, the RNC 110, an ERV with 5 in. collars, delivers 100 cfm net at 0.4 in. (HVI directory).
Installation by AirGreen in Greater Montreal
Before recommending the 30 ERV, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement). Its spec sheet also shows that its airflow drops quickly as static pressure rises: 72 cfm at 0.1 in., 43 cfm at 0.6 in. So we keep the duct run short and direct.
We find it a heated spot where the door stays accessible for service; Lifebreath does not recommend the attic, notably because of freezing. The unit is installed level, as Lifebreath requires for condensate drainage, and we keep the outdoor fresh-air intake away from the dryer vent and the parking area.
At start-up, we first open the balancing dampers fully. The unit then runs on high speed, and we gradually close the damper on the side that moves more air; balancing is done when the fresh air and the stale air show the same flow rate.
AirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore.
For a free quote, call us at 514 316-2973 or write to sales@airgreen.ca.