Lifebreath RNC 110 ERV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: RNC 110
100 cfm net1,200 to 1,900 sq ftERV
Talk to an HVAC technician · 514 316-2973
Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 100 cfm net, enough to ventilate 1,200 to 1,900 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 100 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
72%
At 0 °CCertified at 49 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench119 cfm
0.4 in · with ducts100 cfm

$59.54

Electricity per year

Less than a 100 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

61W
Running continuously
534kWh
Per year
3months
Filter cleaning

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 61 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

3-in-1Three units in one via high-speed select

DIP switches on the circuit board set the high speed (Hi 3 is the factory setting). Lifebreath calls it “three units in one” for better control of airflow and comfort.

DampersBalancing dampers built into the top collars

The 5 in round collars on top have built-in balancing dampers, and measuring ports are provided on the door, so the installer balances airflow right at the unit.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005391Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 119 to 100 cfm. Most spec sheets show only the first number, precisely because it looks better.

61 WMeasured at the airflow it actually runs at

Its 72% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 61 W, or about 534 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in ducts, top connection. It weighs 51 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Top connectionTop ports
51 lbUnit weight
22.8 × 12.7 × 17.2 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
119 cfm
Net airflow at 0.4 in. w.g.
100 cfm
SRE at 0 °C (49 cfm)
72%
ASE at 0 °C
81%
Power draw
61 W
Efficacy
0.8 cfm/W
Type
ERV
Connection
Top ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable MERV 8 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
22.8 × 12.7 × 17.2 in
Weight
51 lb
Power supply
120 V
HVI certification (Section III)
2005391
Warranty — core
5 years
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005391). The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up. Annual consumption calculated at 61 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Three units in one, with MERV 8 filters

The Lifebreath RNC 110 is a top-ported energy recovery ventilator (ERV). Lifebreath calls it “three units in one”: DIP switches on its circuit board set the high speed, factory-set at Hi 3, and the installation manual gives an airflow curve for each of the three settings available to the installer.

At 0.4 in. of static pressure, its net airflow is 100 cfm, and 119 cfm at 0.2 in.

MERV 8 filters from the start

Most of the other Lifebreath residential units in our lineup have MERV 6 filters. The RNC 110, for its part, filters both of its airstreams, stale and fresh, with washable MERV 8 filters: its filtration is a notch finer from day one. Part 65-195-6R takes it to MERV 13.

Heat and humidity

Its cross-flow enthalpy core recovers both heat and moisture from the air it exhausts. In winter, the indoor air dries out less; in summer, part of the outdoor humidity stays outside, which eases the load on the air conditioning when the home has it. HVI rates it at 72% sensible recovery efficiency at 0 °C and 49 cfm, and 43% total recovery efficiency in cooling, at 35 °C and 64 cfm. For cleaning, the core is easily removed.

This model has no HVI rating at −25 °C, and Lifebreath does not publish one either: it therefore cannot show that it meets the requirement of art. 9.36.3.9 of the Québec Construction Code where it applies. If your project has to meet it, we will suggest a model rated at −25 °C. The RNC 110 uses fan defrost.

Energy use

An independent motorized impeller with several speeds moves each airstream. HVI records 61 W at 49 cfm, its first test point, or 0.8 cfm per watt, and 73 W at 64 cfm. Run continuously at 49 cfm, that comes to about 534 kWh a year, around $60 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). At that same 49 cfm point, the METRO 120 ERVD-ECM, the next ERV up in our lineup, draws 21 W and delivers 106 cfm net at 0.4 in. (HVI directory).

Dampers built into the collars

Each of the 5 in. (125 mm) round collars on top carries its own balancing damper, and measuring ports are provided on the door. Balancing is therefore done right at the unit, with no damper to add in the ducts. With this vertical connection, the ducts come down from the ceiling to the unit.

Installation

The unit weighs 51 lb (23 kg) and hangs from the supplied adjustable straps. Its 22-gauge prepainted galvanized steel cabinet is insulated against exterior condensation. For service, Lifebreath recommends 25 in. (635 mm) of clearance at the front. The main control goes on a central wall of the home.

On the drain, Lifebreath's spec sheet contradicts itself: it lists a drain, then states that no drain is required. We check this point with Lifebreath before the installation and plan the connection if needed.

Warranty

Lifebreath warrants the core for 5 years, the motors for 5 years and the parts for 5 years.

Which home it suits

With its 100 cfm net at 0.4 in., the RNC 110 suits a single-family home or a townhouse whose air dries out in winter. If someone in the home has allergies, we also discuss the MERV 13 upgrade at the quote stage.

Installation by AirGreen in Greater Montreal

Before recommending the RNC 110, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement). We then pick, among its three high-speed settings, the one that covers that need with the planned duct length.

This air exchanger goes in a heated spot where its door stays accessible; Lifebreath does not recommend the attic. As Lifebreath requires for condensate to drain away, it is installed perfectly level. At start-up, its collar dampers are first opened fully; on high speed, we then measure the fresh air and the stale air through the door ports, referring to the RNC 110 curves, and partly close the damper on the stronger side until the two readings are identical.

AirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore.

Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.

Ask for your free quote: 514 316-2973 or sales@airgreen.ca. We will call you back to go over your project.