Lifebreath METRO 120 ERVD-ECM ERV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: METRO 120 ERVD-ECM
106 cfm net1,200 to 2,000 sq ft56% at −25 °C
Talk to an HVAC technician · 514 316-2973
Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 106 cfm net, enough to ventilate 1,200 to 2,000 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 106 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
56%
At −25 °CCode: 55% or 60% minimum
74%
At 0 °CCertified at 49 cfm
Net airflowThe ducts cost it 17 cfm
0.2 in · test bench123 cfm
0.4 in · with ducts106 cfm

$20.50

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

21W
Running continuously
184kWh
Per year
3months
Filter cleaning

Meets the Code's 55% threshold; below the 60% it requires where there are 6,000 degree-days or more. At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 56% at 55 cfm (HVI).

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 21 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

ECMHigh-efficiency ECM blower on each airstream

Each airstream has its own high-efficiency ECM centrifugal blower with multiple speeds. That is what the “-ECM” suffix of this METRO 120 ERVD version refers to.

ExternalExternally mounted e-box

The e-box is mounted on the outside of the unit for quick access to the circuit board and DIP switches. A mirrored version is sold as METRO-120ERVD-ECM-M.

56%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 55 cfm.

DamperIt defrosts with indoor air

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2004901Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−17 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 123 to 106 cfm. Most spec sheets show only the first number, precisely because it looks better.

21 WMeasured at the airflow it actually runs at

Its 74% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 21 W, or about 184 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
34 lbUnit weight
25.75 × 19.38 × 9.75 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
123 cfm
Net airflow at 0.4 in. w.g.
106 cfm
SRE at 0 °C (49 cfm)
74%
SRE at −25 °C (55 cfm)
56%
ASE at 0 °C
77%
Power draw
21 W
Efficacy
2.3 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
25.75 × 19.38 × 9.75 in
Weight
34 lb
Power supply
120 V
HVI certification (Section III)
2004901
Warranty — core
5 years
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2004901). Annual consumption calculated at 21 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The damper-defrost METRO ERV, rated at −25°C

At 9.75 in. high, the Lifebreath METRO 120 ERVD-ECM is the energy recovery ventilator (ERV) in the METRO 120 series that pairs ECM motors with a recirculating damper for defrost, controlled by a temperature sensor. Unlike the METRO 120 ERV-ECM, it has an HVI rating at −25°C, and its spec sheet describes it as cold weather certified.

At 0.2 in. of static pressure, it delivers 123 cfm net; at 0.4 in., it still gives 106.

Performance in the Cold

At 0°C and 49 cfm, HVI gives it 74% sensible recovery efficiency. At −25°C and 55 cfm (26 L/s), its sensible recovery efficiency is 56% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. The unit therefore clears the 55% bar, but stays below the 60% one.

Below −3°C, a motorized damper closes the outdoor air inlet from time to time, and the home's own air flows through the core to defrost it. The METRO manual counts 4.5 minutes of this defrost at −20°C for every 17 minutes of ventilation; once started, no remote accessory can interrupt it.

Heat and Humidity, With No Drain

The cross-flow core passes heat and part of the water vapour from the stale air to the fresh air. In cold weather, the indoor air therefore dries out less; in hot weather, part of the outdoor humidity stays out. In summer, at 35°C and the 49 cfm test airflow, its total recovery efficiency reaches 50% according to HVI. According to Lifebreath's spec sheet, no drain is required: no condensate line to run through a dropped ceiling.

External E-Box

On this model, Lifebreath mounts the e-box on the outside of the unit, for quick access to the circuit board and DIP switches. In a tight bulkhead, an adjustment therefore does not require opening the door. A mirrored version exists under the code METRO-120ERVD-ECM-M; we choose it when the ducts come in from the opposite side.

ECM Motors

Two independent centrifugal blowers, each with its own high-efficiency, multi-speed ECM motor, move the air. HVI measures 21 W at 49 cfm, or 2.3 cfm per watt; at the same test airflow, it records 22 W on the METRO 120 ERV-ECM and 18 W on the METRO 120F-ECM. Running nonstop at that rate, the unit uses about 184 kWh a year, or some $20 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).

Installation

Its spec sheet and the METRO manual give 25.75 in. for its largest dimension and 9.75 in. for its height, but they agree neither on the third dimension nor on the weight; we take both readings on the unit before planning the support and the bulkhead. The ceiling mounting brackets are supplied, and the four ducts connect to 5 in. (125 mm) round collars. Lifebreath calls for 25 in. (635 mm) of clearance at the front for service. No screws hold the hinged door, and the motor and electronics assembly comes out in one piece. The main control mounts on a wall in a central room; the METRO manual rules out the 99-BC03 and 99-BC04 basic controls on this model, but not the 99-DXPL03.

Filters

Two washable MERV 6 filters protect the core, one on the stale air and the other on the fresh air, and part 65-195-6R replaces them with MERV 13 filters. The core comes out easily; as with any ERV core, the METRO manual wants it cleaned with a vacuum, never with water.

Warranty

Lifebreath warrants the core, the motors and the parts for 5 years each.

Which Home It Suits

The METRO 120 ERVD-ECM is for condos, apartments and townhomes whose air dries out in winter and where the only mechanical space is a bulkhead: it brings a −25°C rating, no drain and 21 W at the test point, for 106 cfm net at 0.4 in. Where the Code requires 60% at −25°C, another Lifebreath model is the right call.

Installation by AirGreen in Greater Montreal

We assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement), then check that the METRO 120 ERVD-ECM's 106 cfm net at 0.4 in. meets them. In a condo, we also look at access to the e-box and at the duct route to the outside wall.

Lifebreath wants the unit in a heated space and advises against the attic. The METRO manual also asks that no clothes dryer, range hood or central vacuum be connected to it. Between the unit and the outdoor hoods, we install insulated flexible duct, pulled taut and kept as short as possible, and sealed, insulated rigid duct beyond 10 ft (3.3 m), as the METRO manual specifies.

Lifebreath lists the METRO 120 ERVD-ECM among its factory-balanced units: if no more than 0.3 in. of static pressure difference is measured between its supply and exhaust ducts, its two airflows do not diverge by more than 10%. These readings are part of our start-up.

Our team, under AirGreen's RBQ licence 5645-9605-01, installs the METRO 120 ERVD-ECM in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.

For a free quote, call us at 514 316-2973 or write to us at sales@airgreen.ca: we will call you back.