Is it the right size for your home?
It delivers 108 cfm net, enough to ventilate 1,200 to 2,000 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 108 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$21.47
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 22 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
ECMHigh-efficiency ECM blower on each airstream
Each airstream has its own high-efficiency ECM centrifugal blower with multiple speeds. That is what the “-ECM” suffix of this METRO 120 ERV version refers to.
AB / FIDMirrored, -AB and -FID versions offered
Lifebreath offers hardwired, mirrored, auto-balance (-AB) and fault indication display (-FID) configurations. The FID version, Title 24 compliant, displays error codes for certain faults.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2004837Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 123 to 108 cfm. Most spec sheets show only the first number, precisely because it looks better.
22 WMeasured at the airflow it actually runs at
Its 72% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 22 W, or about 193 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 123 cfm
- Net airflow at 0.4 in. w.g.
- 108 cfm
- SRE at 0 °C (49 cfm)
- 72%
- ASE at 0 °C
- 75%
- Power draw
- 22 W
- Efficacy
- 2.2 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 20.75 × 19.38 × 9.75 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2004837
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2004837). The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up. Annual consumption calculated at 22 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A slim ERV with no drain, for condos
In a condo, the Lifebreath METRO 120 ERV-ECM meets two constraints at once: space and water drainage. This energy recovery ventilator (ERV) is only 9.75 in. high, and its spec sheet states that no drain is required. Lifebreath intends it for townhomes, apartments and high-rise condos where mechanical space is scarce.
Its net airflow goes from 123 cfm at 0.2 in. of static pressure to 108 cfm at 0.4 in.
No Drain to Run Through the Ceiling
The HRVs in the METRO 120 series connect to a drain cup. For the METRO ERVs, Lifebreath's manual provides no condensate connection, and the METRO 120 ERV-ECM spec sheet confirms it: "DRAIN: No". In a condo where the only floor drain is in the laundry room, this avoids running a line through the dropped ceiling, with its slope and its trap.
Heat and Humidity
In its cross-flow core, the outgoing air passes its heat and part of its moisture to the incoming air. In the cold season, the fresh air therefore reaches the home less dry; in summer, the core keeps part of the humidity outside. In the HVI directory, at 0°C and 49 cfm, the sensible recovery efficiency is 72%, and in cooling mode, at 35°C and the same airflow, the total recovery efficiency reaches 51%.
HVI, however, publishes no rating at −25°C for this unit, and neither does its spec sheet. Since art. 9.36.3.9 of the Québec Construction Code sets the required efficiency at −25°C, at no less than 22 L/s (55% where there are fewer than 6,000 heating degree-days, 60% elsewhere), the METRO 120 ERV-ECM cannot show compliance where that article applies.
Defrost is by fan: as soon as the outdoor temperature drops below −3°C, the supply air shuts off in cycles and warm stale air, at high speed, clears the core. At −35°C, the METRO manual provides for 7 minutes of defrost every time the unit has ventilated for 15 minutes.
ECM Motors
A high-efficiency, multi-speed ECM centrifugal blower moves each of the two airstreams. At the 49 cfm HVI test point, the unit draws 22 W, or 2.2 cfm per watt, while the METRO 120 ERV needs 60 W at the same airflow. Running continuously, that comes to about 193 kWh a year, around $21 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Available Versions
Lifebreath offers hardwired, mirrored, auto-balance (-AB) and fault indication display (-FID) configurations, the last one offered for California Title 24 compliance. The mirrored version reverses the layout of the airstreams, which helps when the ducts come in from the opposite side. The corded METRO 120 ERV-ECM can also be reversed on site by the contractor: the METRO manual describes the nine steps, the last of which is swapping the supply and exhaust motor connections, so that the right motor stops during defrost.
Installation
The cabinet weighs 34 lb. Lifebreath's two documents agree on its 9.75 in. height and on a 20.75 in. dimension, but not on the third one; we measure it before planning the bulkhead. Ceiling mounting brackets are supplied, and each of the four ducts connects to a 5 in. (125 mm) round collar. For service, 25 in. (635 mm) must be left clear in front of the door, according to Lifebreath. The hinged door needs no screws, and the motor and electronics assembly comes out for service. The optional control goes on a wall in a central room; the 99-DXPL03 works, but not the 99-BC03 and 99-BC04 basic controls, which the METRO manual rules out on this model.
Filters
On the stale-air side as on the fresh-air side, the unit takes a washable MERV 6 filter; Lifebreath also offers MERV 13 filters (part 65-195-6R). The core comes out easily, but an ERV core is not washed: the METRO manual calls for cleaning it with a vacuum only, twice a year.
Warranty
Lifebreath warrants the core for 5 years, the motors for 5 years and the parts for 5 years.
Which Home It Suits
The METRO 120 ERV-ECM suits condos and apartments whose air dries out in winter and where no one wants a drain in the ceiling, as long as 108 cfm net at 0.4 in. covers the needs. If your project has to show a −25°C rating, we look instead at the METRO 120 ERVD-ECM, which HVI rates at 56% at that temperature.
Installation by AirGreen in Greater Montreal
We assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement), then compare the total with the METRO 120 ERV-ECM's 108 cfm net. If it is not the right fit, we offer you another Lifebreath model. In a condo, where the two exterior openings go also depends on what the condo board allows.
The unit goes in a heated space; Lifebreath advises against the attic. Outside, we keep the fresh-air intake away from gas meters, oil fill pipes and garbage bins, while the stale-air outlet must avoid gas and electric meters as well as walkways where fog or ice would be a hazard, as Lifebreath requires.
The standard version is among the units Lifebreath considers factory balanced: if the static pressures of its supply and exhaust ducts stay within 0.3 in. of each other, the two airflows do not drift more than 10% apart. We take these readings when the unit is started up. The AB and FID versions, for their part, are balanced with the collar port method in the METRO manual.
Our team, under AirGreen's RBQ licence 5645-9605-01, installs the METRO 120 ERV-ECM in Montreal, Laval, Longueuil, the South Shore and the North Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
For an installed price, ask for a free quote at 514 316-2973 or sales@airgreen.ca: we will call you back.