Lifebreath 205 MAX HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 170 cfm net, enough to ventilate 2,000 to 3,200 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 170 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$56.61
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 69% at 70 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 58 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
DXPL03DXPL03 digital wall control included
Lifebreath states that the DXPL03 digital control is included and easy to program. It mounts on a wall in a central spot in the home (3-wire 20 ga cable, up to 100 ft).
DIPHigh speed selected by DIP switch
DIP switches on the circuit board select the high speed (Hi 3 is the factory setting). The balancing ports are on the door and the dampers are adjustable.
69%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 70 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505460Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−21 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 191 to 170 cfm. Most spec sheets show only the first number, precisely because it looks better.
58 WMeasured at the airflow it actually runs at
Its 83% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 58 W, or about 508 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection and a condensate drain. It weighs 57 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 191 cfm
- Net airflow at 0.4 in. w.g.
- 170 cfm
- SRE at 0 °C (49 cfm)
- 83%
- SRE at −25 °C (70 cfm)
- 69%
- ASE at 0 °C
- 91%
- Power draw
- 58 W
- Efficacy
- 0.8 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 33.63 × 15 × 18.75 in
- Weight
- 57 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505460
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505460). Annual consumption calculated at 58 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
All collars on top, 83% efficiency at 0 °C
The Lifebreath 205 MAX is a heat recovery ventilator (HRV) whose connections are all on top, none on the sides. In a basement mechanical room, where the ducts almost always come down from the ceiling, this layout avoids tight elbows on the sides and lets the unit sit close to a wall.
Lifebreath publishes its net airflow up to 0.9 in. of static pressure: 199 cfm at 0.1 in., 191 cfm at 0.2 in., 170 cfm at 0.4 in., and still 114 cfm at 0.9 in. The HVI directory also lists 170 cfm net at 0.4 in.
Counter-flow HEX core
This heat-conducting core passes the heat of the stale air to the fresh air: in winter, the incoming air arrives already warmed, and the heating system has less of a gap to make up. HVI tested it at three airflows at 0 °C, with a sensible recovery efficiency of 83% at 49 cfm, 82% at 64 cfm and 79% at 95 cfm. At −25 °C and 70 cfm, its sensible recovery efficiency is 69% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at a minimum of 22 L/s. The 205 MAX therefore meets both thresholds. For cleaning, the core slides out of the unit without difficulty.
In the HVI directory, its ratings are identical to those of the RNC 205, which we also offer. The 205 MAX is also on Natural Resources Canada's ENERGY STAR list.
DXPL03 control and selectable high speed
According to Lifebreath, the DXPL03, an easy-to-program digital wall control, comes with the unit. It goes on a wall, in a central room; the wiring to the HRV calls for three conductors of 20 gauge or heavier, running 100 ft at most. The high-speed setting is chosen on the circuit board, with DIP switches, and leaves the factory at Hi 3.
The balancing ports are on the door and the dampers are adjustable: the airflows are measured and adjusted right at the unit.
Energy use
The two centrifugal blowers, one per airstream, share a common PSC motor. HVI measures 58 W at 49 cfm, or 0.8 cfm per watt, then 66 W at 64 cfm and 86 W at 95 cfm; at −25 °C and 70 cfm, the unit draws 117 W. Left running continuously at the 49 cfm setting, it uses about 508 kWh a year, around $57 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Defrost
Defrost works through a recirculating damper, a system Lifebreath calls intelligent: during the cycle, house air takes the place of outdoor air in the core, which melts the frost.
Installation
The cabinet measures 33.63 in. long, 15 in. deep and 18.75 in. high, and weighs 57 lb. The 22-gauge prepainted galvanized steel keeps corrosion at bay, and the cabinet's insulation stops condensation from appearing on its outer faces. To hang it, Lifebreath supplies “S” hooks and straps that attach to four threaded inserts, one per corner. All the ducts connect to 6 in. round collars. The condensate drain is mandatory; the unit has two 1/2 in. (12 mm) OD outlets. To open the door and do maintenance, Lifebreath recommends 25 in. of clear space at the front.
Filters
A washable MERV 6 filter protects each airstream, stale and fresh. Lifebreath offers a step up to MERV 13 with part 65-195-6R.
Warranty
Core warranted for life; motors and parts warranted for 5 years by Lifebreath.
Which home it suits
The 205 MAX suits a single-family home with its mechanical room in the basement, where the main ducts run between the joists; its 170 cfm net at 0.4 in. is aimed at a good-sized house with several bedrooms and bathrooms. Its top connections work as well for new construction as for replacing an old air exchanger.
Installation by AirGreen in Greater Montreal
Before recommending the 205 MAX, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement), then we check that its 170 cfm net meets them. In an existing home, we also look at whether the current ducts are 6 in. or whether reducers to the unit's collars are needed.
The drain is assembled with a tee pointing upward and two lengths of 1/2 in. hose, which Lifebreath does not supply; the trap and hose stay lower than the bottom of the door, sloping 1/4 in. per foot toward the drain, in a space that does not freeze. We place the fresh-air intake away from dryer vents and the driveway, and the stale-air outlet away from the gas meter, the electric meter and any walkway where fog or ice would become a hazard, as Lifebreath requires. When the unit starts up for the first time, we balance its two airflows at the door ports, using the chart that Lifebreath's installation manual provides for the 205 MAX, gradually closing the damper on the stronger side until the two readings match.
Our team, under AirGreen's RBQ licence 5645-9605-01, installs the 205 MAX in Montreal, Laval, Longueuil and throughout the North Shore and the South Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
For a free quote, call us at 514 316-2973 or write to sales@airgreen.ca.